summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorGravatar Dirk Hohndel <dirk@hohndel.org>2014-01-03 16:00:28 -0800
committerGravatar Dirk Hohndel <dirk@hohndel.org>2014-01-09 09:27:37 +0800
commita0a96e066421da202a3fcffabecfd8991bc6493d (patch)
tree4e922ac9b9c3b9d1a3bbf3fcb8137182156d0c3d
parent8795be53ae69e8d92633eff7e4ac9afccbaf1148 (diff)
downloadsubsurface-a0a96e066421da202a3fcffabecfd8991bc6493d.tar.gz
Fix Uemis temperature conversion
In commit 3fd39a7a87bf ("Remove some constants and use helpers instead") Anton missed the fact that the Uemis gives temperatures in the handy unit of "centi degree C". Now things work again. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
-rw-r--r--uemis.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/uemis.c b/uemis.c
index e37de36ad..d869180eb 100644
--- a/uemis.c
+++ b/uemis.c
@@ -293,7 +293,7 @@ void uemis_parse_divelog_binary(char *base64, void *datap) {
datalen = uemis_convert_base64(base64, &data);
- dive->dc.airtemp.mkelvin = C_to_mkelvin(*(uint16_t *)(data + 45));
+ dive->dc.airtemp.mkelvin = C_to_mkelvin((*(uint16_t *)(data + 45)) / 10.0);
dive->dc.surface_pressure.mbar = *(uint16_t *)(data + 43);
if (*(uint8_t *)(data + 19))
dive->dc.salinity = SEAWATER_SALINITY; /* avg grams per 10l sea water */
@@ -351,7 +351,7 @@ void uemis_parse_divelog_binary(char *base64, void *datap) {
sample = prepare_sample(dc);
sample->time.seconds = u_sample->dive_time;
sample->depth.mm = rel_mbar_to_depth(u_sample->water_pressure, dive);
- sample->temperature.mkelvin = C_to_mkelvin(u_sample->dive_temperature);
+ sample->temperature.mkelvin = C_to_mkelvin(u_sample->dive_temperature / 10.0);
sample->sensor = active;
sample->cylinderpressure.mbar =
(u_sample->tank_pressure_high * 256 + u_sample->tank_pressure_low) * 10;