summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorGravatar Dirk Hohndel <dirk@hohndel.org>2017-01-16 03:30:57 -0800
committerGravatar Dirk Hohndel <dirk@hohndel.org>2017-01-16 03:30:57 -0800
commit7f7c00824706be24786767599cdde9b91e5cf9c6 (patch)
tree473ee09c3040bbab281ea2e769dfd808150a0be0
parenta8e8d56ec016fc19727e45cd7208bb55ca4821af (diff)
downloadsubsurface-7f7c00824706be24786767599cdde9b91e5cf9c6.tar.gz
Revert "Show both the nominal and "real" size for an imperial cylinder"
This reverts commit adaeb506b7a1485cab741f12450abeb76e109276. commit a8e8d56ec016 ("Tweak cylinder equipment tooltips") does a much better job allowing the user to know the true volume of the cylinder (given the gas entered) and clutters the UI a lot less.
-rw-r--r--qt-models/cylindermodel.cpp3
1 files changed, 1 insertions, 2 deletions
diff --git a/qt-models/cylindermodel.cpp b/qt-models/cylindermodel.cpp
index 530ea6356..767ba7621 100644
--- a/qt-models/cylindermodel.cpp
+++ b/qt-models/cylindermodel.cpp
@@ -38,10 +38,9 @@ static QString get_cylinder_string(cylinder_t *cyl)
// liters: if we don't have a working pressure, we cannot
// convert the cylinder size to cuft.
if (wp.mbar && prefs.units.volume == units::CUFT) {
- double real_value = ml_to_cuft(gas_volume(cyl, wp));
value = ml_to_cuft(ml) * bar_to_atm(wp.mbar / 1000.0);
decimals = (value > 20.0) ? 0 : (value > 2.0) ? 1 : 2;
- unit = QString("(%1)%2").arg(real_value, 0, 'f', 0).arg(CylindersModel::tr("cuft"));
+ unit = CylindersModel::tr("cuft");
} else {
value = ml / 1000.0;
decimals = 1;