summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorGravatar Linus Torvalds <torvalds@linux-foundation.org>2017-07-24 11:55:47 -0700
committerGravatar Dirk Hohndel <dirk@hohndel.org>2017-07-25 06:11:10 -0700
commitadb4b66a055ca809b0a78c08f37d7feefe44e947 (patch)
tree2abdcf4ecbc9f83ffa7df11ed95b17062704adcd
parent97b770b837d53039cdebc20957b62b75840d629b (diff)
downloadsubsurface-adb4b66a055ca809b0a78c08f37d7feefe44e947.tar.gz
Try to sanely download multiple concurrent cylinder pressures
This tries to sanely handle the case of a dive computer reporting multiple cylinder pressures concurrently. NOTE! There are various "interesting" situations that this whole issue brings up: - some dive computers may report more cylinder pressures than we have slots for. Currently we will drop such pressures on the floor if they come for the same sample, but if they end up being spread across multiple samples we will end up re-using the slots with different sensor indexes. That kind of slot re-use may or may not end up confusing other subsurface logic - for example, make things believe there was a cylidner change event. - some dive computers might send only one sample at a time, but switch *which* sample they send on a gas switch event. If they also report the correct sensor number, we'll now start reporting that pressure in the second slot. This should all be fine, and is the RightThing(tm) to do, but is different from what we used to do when we only ever used a single slot. - When people actually use multiple sensors, our old save format will start to need fixing. Right now our save format comes from the CCR model where the second sensor was always the Oxygen sensor. We save that pressure fine (except we save it as "o2pressure" - just an odd historical naming artifact), but we do *not* save the actual sensor index, because in our traditional format that was always implicit in the data ("it's the oxygen cylinder"). so while this code hopefully makes our libdivecomputer download do the right thing, there *will* be further fallout from having multiple cylinder pressure sensors. We're not done yet. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
-rw-r--r--core/dive.c7
-rw-r--r--core/dive.h5
-rw-r--r--core/libdivecomputer.c51
3 files changed, 53 insertions, 10 deletions
diff --git a/core/dive.c b/core/dive.c
index 6406242bf..8270c5478 100644
--- a/core/dive.c
+++ b/core/dive.c
@@ -648,6 +648,13 @@ struct sample *prepare_sample(struct divecomputer *dc)
}
sample = dc->sample + nr;
memset(sample, 0, sizeof(*sample));
+
+ // Copy the sensor numbers - but not the pressure values
+ // from the previous sample if any.
+ if (nr) {
+ sample->sensor[0] = sample[-1].sensor[0];
+ sample->sensor[1] = sample[-1].sensor[1];
+ }
return sample;
}
return NULL;
diff --git a/core/dive.h b/core/dive.h
index 2d1b761f0..df0c4107e 100644
--- a/core/dive.h
+++ b/core/dive.h
@@ -184,6 +184,7 @@ static inline int interpolate(int a, int b, int part, int whole)
void get_gas_string(const struct gasmix *gasmix, char *text, int len);
const char *gasname(const struct gasmix *gasmix);
+#define MAX_SENSORS 2
struct sample // BASE TYPE BYTES UNITS RANGE DESCRIPTION
{ // --------- ----- ----- ----- -----------
duration_t time; // uint32_t 4 seconds (0-68 yrs) elapsed dive time up to this sample
@@ -194,11 +195,11 @@ struct sample // BASE TYPE BYTES UNITS RANGE DE
depth_t depth; // int32_t 4 mm (0-2000 km) dive depth of this sample
depth_t stopdepth; // int32_t 4 mm (0-2000 km) depth of next deco stop
temperature_t temperature; // int32_t 4 mdegrK (0-2 MdegK) ambient temperature
- pressure_t pressure[2]; // int32_t 4 mbar (0-2 Mbar) cylinder pressures (main and CCR o2)
+ pressure_t pressure[MAX_SENSORS]; // int32_t 4 mbar (0-2 Mbar) cylinder pressures (main and CCR o2)
o2pressure_t setpoint; // uint16_t 2 mbar (0-65 bar) O2 partial pressure (will be setpoint)
o2pressure_t o2sensor[3]; // uint16_t 6 mbar (0-65 bar) Up to 3 PO2 sensor values (rebreather)
bearing_t bearing; // int16_t 2 degrees (-32k to 32k deg) compass bearing
- uint8_t sensor[2]; // uint8_t 1 sensorID (0-255) ID of cylinder pressure sensor
+ uint8_t sensor[MAX_SENSORS]; // uint8_t 1 sensorID (0-255) ID of cylinder pressure sensor
uint8_t cns; // uint8_t 1 % (0-255 %) cns% accumulated
uint8_t heartbeat; // uint8_t 1 beats/m (0-255) heart rate measurement
volume_t sac; // 4 ml/min predefined SAC
diff --git a/core/libdivecomputer.c b/core/libdivecomputer.c
index c935ecbce..819db0226 100644
--- a/core/libdivecomputer.c
+++ b/core/libdivecomputer.c
@@ -307,6 +307,47 @@ static void handle_gasmix(struct divecomputer *dc, struct sample *sample, int id
current_gas_index = idx;
}
+/*
+ * Adding a cylinder pressure sample field is not quite as trivial as it
+ * perhaps should be.
+ *
+ * We try to keep the same sensor index for the same sensor, so that even
+ * if the dive computer doesn't give pressure information for every sample,
+ * we don't move pressure information around between the different sensor
+ * indexes.
+ *
+ * The "prepare_sample()" function will always copy the sensor indices
+ * from the previous sample, so the indexes are pre-populated (but the
+ * pressures obviously are not)
+ */
+static void add_sample_pressure(struct sample *sample, int sensor, int mbar)
+{
+ int idx;
+
+ if (!mbar)
+ return;
+
+ /* Do we already have a slot for this sensor */
+ for (idx = 0; idx < MAX_SENSORS; idx++) {
+ if (sensor != sample->sensor[idx])
+ continue;
+ sample->pressure[idx].mbar = mbar;
+ return;
+ }
+
+ /* Pick the first unused index if we couldn't reuse one */
+ for (idx = 0; idx < MAX_SENSORS; idx++) {
+ if (sample->pressure[idx].mbar)
+ continue;
+ sample->sensor[idx] = sensor;
+ sample->pressure[idx].mbar = mbar;
+ return;
+ }
+
+ /* We do not have enough slots for the pressure samples. */
+ /* Should we warn the user about dropping pressure data? */
+}
+
void
sample_cb(dc_sample_type_t type, dc_sample_value_t value, void *userdata)
{
@@ -352,15 +393,9 @@ sample_cb(dc_sample_type_t type, dc_sample_value_t value, void *userdata)
case DC_SAMPLE_DEPTH:
sample->depth.mm = lrint(value.depth * 1000);
break;
- case DC_SAMPLE_PRESSURE: {
- int sensoridx = 0;
- /* Do we already have a pressure reading? */
- if (sample->pressure[0].mbar)
- sensoridx = 1;
- sample->sensor[sensoridx] = value.pressure.tank;
- sample->pressure[sensoridx].mbar = lrint(value.pressure.value * 1000);
+ case DC_SAMPLE_PRESSURE:
+ add_sample_pressure(sample, value.pressure.tank, lrint(value.pressure.value * 1000));
break;
- }
case DC_SAMPLE_GASMIX:
handle_gasmix(dc, sample, value.gasmix);
break;