diff options
author | Robert C. Helling <helling@atdotde.de> | 2014-10-14 10:46:40 +0200 |
---|---|---|
committer | Dirk Hohndel <dirk@hohndel.org> | 2014-10-14 20:33:46 +0200 |
commit | 34bb461c3de7cd0b8d9d3eaf13b1bc45973c16d3 (patch) | |
tree | 004b027f32e7f1981704d20e0a01778bf132b60f | |
parent | 4cdb80c4cd3836fdbacf50f62e9c76f0efca244b (diff) | |
download | subsurface-34bb461c3de7cd0b8d9d3eaf13b1bc45973c16d3.tar.gz |
Reshuffle CCR voting logic and minor clean ups
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
-rw-r--r-- | dive.c | 10 | ||||
-rw-r--r-- | profile.c | 97 |
2 files changed, 37 insertions, 70 deletions
@@ -1537,12 +1537,14 @@ int gasmix_distance(const struct gasmix *a, const struct gasmix *b) extern void fill_pressures(struct gas_pressures *pressures, const double amb_pressure, const struct gasmix *mix, double po2) { if (po2) { // This is probably a CCR dive where pressures->o2 is defined - if (po2 >= amb_pressure || get_o2(mix) == 1000) + if (po2 >= amb_pressure || get_o2(mix) == 1000) { pressures->o2 = amb_pressure; - else + pressures->n2 = pressures->he = 0.0; + } else { pressures->o2 = po2; - pressures->he = (amb_pressure - pressures->o2) * (double)get_he(mix) / (1000 - get_o2(mix)); - pressures->n2 = amb_pressure - pressures->o2 - pressures->he; + pressures->he = (amb_pressure - pressures->o2) * (double)get_he(mix) / (1000 - get_o2(mix)); + pressures->n2 = amb_pressure - pressures->o2 - pressures->he; + } } else { // Open circuit dives: no gas pressure values available, they need to be calculated pressures->o2 = get_o2(mix) / 1000.0 * amb_pressure; // These calculations are also used if the CCR calculation above.. @@ -4,6 +4,7 @@ #include "gettext.h" #include <limits.h> #include <string.h> +#include <assert.h> #include "dive.h" #include "display.h" @@ -832,76 +833,40 @@ void calculate_deco_information(struct dive *dive, struct divecomputer *dc, stru * there are and the differences among the readings from these sensors. */ double calculate_ccr_po2(struct plot_data *entry, struct divecomputer *dc) { - double sensor_j, sump, midp, minp, maxp; + double sump = 0.0, midp, minp = 999.9, maxp = -999.9; double diff_limit = 100; // The limit beyond which O2 sensor differences are considered significant (default = 100 mbar) - int num_of_diffs; // The number of unacceptable differences among the ogygen sensor partial pressure measurements - int i, j, np; - bool maxdif = false, mindif = false; - struct gas_pressures *pressures = &(entry->pressures); - - // Estimate the most reliable PO2, given the different oxygen partial pressure values from the O2 sensors - switch (dc->no_o2sensors) { - case 2: { // For 2 sensors: take the mean value of the two partial pressure sensors. - for (np = 0, sump = 0, j = 0; j < 2; j++) { // This calculation allows that for some samples - if (entry->o2sensor[j]) { // (especially at start of dive) with an inactive sensor,the - np++; // sensor(s) with zero values are not used. - sump = sump + entry->o2sensor[j]; - } - } - if (np > 0) // if there is at least one sensor value - return (sump / np); // then calculate the mean, else - else - return 0; // if there are no valid sensor values, calculate po2 on the basis of depth. - break; + int i, j, np = 0; + + for (i=0; i < dc->no_o2sensors; i++) + if (entry->o2sensor[i]) { // Valid reading + ++np; + sump += entry->o2sensor[i]; + minp = MIN(minp, entry->o2sensor[i]); + maxp = MAX(maxp, entry->o2sensor[i]); } - case 3: { /* For 3 sensors: diff_limit is the critical limit indicating unacceptable difference (default = 100 mbar). - * a) If all three readings are within a range of diff_limit, then take the mean value. This - * includes the case where reading 1 is within diff_limit of reading 2; and reading 2 is - * within diff_limit of reading 3, but readings 1 and 3 differ by more than diff_limit. - * b) If one sensor differs by more than diff-limit from the other two, then take the mean - * of the closer two sensors and disregard the 3rd sensor, considered as an outlier. - * c) If all 3 sensors differ by more than diff_limit then take the mean of the 3 readings. */ - for (minp = 9999999999, maxp = -1, sump = 0, j = 0; j < 3; j++) { - sensor_j = entry->o2sensor[j]; - if (sensor_j < minp) - minp = sensor_j; - if (sensor_j > maxp) - maxp = sensor_j; - sump = sump + sensor_j; // Find min, max and mid of p-values - } - midp = sump - minp - maxp; - num_of_diffs = 0; - if ((maxp - midp) > diff_limit) { - num_of_diffs++; - maxdif = true; - } - if ((midp - minp) > diff_limit) { - num_of_diffs++; - mindif = true; // Find no of unacceptable differences - } - switch (num_of_diffs) { - case 0: - ; - case 2: { - return (sump / 3); // 0 or 2 unacceptable differences: find mean of three values. - break; - } - case 1: { - if (maxdif) // 1 unacceptable difference: find mean of two closer values - return ((minp + midp) / 2); - else if (mindif) - return ((maxp + midp) / 2); - break; - } - } //switch no_of_diffs - } - default: { // if # of sensors is 1 or unknown, simply take the value of the first sensor - if (entry->o2sensor[0]) - return (entry->o2sensor[0]); + switch (np) { + case 0: // Uhoh + return entry->o2setpoint; + case 1: // Return what we have + return sump; + case 2: // Take the average + return sump / 2; + case 3: // Voting logic + if (2 * maxp - sump + minp < diff_limit) { // Upper difference acceptable... + if (2 * minp - sump + maxp) // ...and lower difference acceptable + return sump / 3; else - return 0; // if no sensor value found, then go to next section, esimating PO2 using depth. + return (sump - minp) / 2; + } else { + if (2 * minp - sump + maxp) // ...but lower difference acceptable + return (sump - maxp) / 2; + else + return sump / 3; } - } // switch + default: // This should not happen + assert(np <= 3); + return 0.0; + } } static void calculate_gas_information_new(struct dive *dive, struct plot_info *pi) |