summaryrefslogtreecommitdiffstats
path: root/dive.c
diff options
context:
space:
mode:
authorGravatar Robert C. Helling <helling@atdotde.de>2015-02-07 21:02:02 +0100
committerGravatar Dirk Hohndel <dirk@hohndel.org>2015-02-10 14:56:33 -0800
commit8fa205a59dc221ad6739de62cdcafc3b655863f9 (patch)
treedf22c23419f9764fe50854234495e84a21963ef6 /dive.c
parente44deed73409001e0cd874ebd0998feaf290f3a7 (diff)
downloadsubsurface-8fa205a59dc221ad6739de62cdcafc3b655863f9.tar.gz
Be a bit more careful when deleting pO2 values
This patch adds tests if the computer is actually a Predator and if the value is close to what we would have computed anyway. [Dirk Hohndel: minor change to use same_string() ] Signed-off-by: Robert C. Helling <helling@atdotde.de> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Diffstat (limited to 'dive.c')
-rw-r--r--dive.c22
1 files changed, 19 insertions, 3 deletions
diff --git a/dive.c b/dive.c
index aebeeca2e..dfb3dc783 100644
--- a/dive.c
+++ b/dive.c
@@ -883,12 +883,28 @@ void update_setpoint_events(struct divecomputer *dc)
if (dc->divemode == CCR)
new_setpoint = prefs.defaultsetpoint;
- if (dc->divemode == OC)
+ if (dc->divemode == OC && same_string(dc->model, "Shearwater Predator")) {
// make sure there's no setpoint in the samples
// this is an irreversible change - so switching a dive to OC
// by mistake when it's actually CCR is _bad_
- for (int i = 0; i < dc->samples; i++)
- dc->sample[i].setpoint.mbar = 0;
+ // So we make sure, this comes from a Predator and we only remove
+ // pO2 values we would have computed anyway.
+ struct event *ev = get_next_event(dc->events, "gaschange");
+ struct gasmix *gasmix = get_gasmix_from_event(ev);
+ struct event *next = get_next_event(ev, "gaschange");
+
+ for (int i = 0; i < dc->samples; i++) {
+ struct gas_pressures pressures;
+ if (next && dc->sample[i].time.seconds >= next->time.seconds) {
+ ev = next;
+ gasmix = get_gasmix_from_event(ev);
+ next = get_next_event(ev, "gaschange");
+ }
+ fill_pressures(&pressures, calculate_depth_to_mbar(dc->sample[i].depth.mm, dc->surface_pressure, 0), gasmix ,0, OC);
+ if (abs(dc->sample[i].setpoint.mbar - (int)(1000 * pressures.o2) <= 50))
+ dc->sample[i].setpoint.mbar = 0;
+ }
+ }
// an "SP change" event at t=0 is currently our marker for OC vs CCR
// this will need to change to a saner setup, but for now we can just