diff options
author | Berthold Stoeger <bstoeger@mail.tuwien.ac.at> | 2019-07-05 23:14:07 +0200 |
---|---|---|
committer | Dirk Hohndel <dirk@hohndel.org> | 2019-07-18 05:50:22 -0700 |
commit | 469cc68b029ac3308b4338a43acfa21679493e8b (patch) | |
tree | 110eaf78f7c1123784313009f2b8ee4844ec16f8 /profile-widget/profilewidget2.cpp | |
parent | 29005b578de4680556f6a3fa01781a8af842ced8 (diff) | |
download | subsurface-469cc68b029ac3308b4338a43acfa21679493e8b.tar.gz |
Cleanup: replace pressure reading macros by inline functions
Replace the INTERPOLATED_PRESSURE and SENSOR_PRESSURE macros by
inline functions. Generate a common inline function that reads
a pressure value for a dynamic sensor.
Not all SENSOR_PRESSURE macros can be replaced, because the
macro is also used to set the value and C sadly doesn't know
the concept of "return reference from a function".
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Diffstat (limited to 'profile-widget/profilewidget2.cpp')
-rw-r--r-- | profile-widget/profilewidget2.cpp | 8 |
1 files changed, 4 insertions, 4 deletions
diff --git a/profile-widget/profilewidget2.cpp b/profile-widget/profilewidget2.cpp index f3cf31c50..6e311d117 100644 --- a/profile-widget/profilewidget2.cpp +++ b/profile-widget/profilewidget2.cpp @@ -1535,19 +1535,19 @@ void ProfileWidget2::contextMenuEvent(QContextMenuEvent *event) if (gasChangeEntry + 1 <= plotInfo.entry + plotInfo.nr) { newGasEntry = gasChangeEntry + 1; qDebug() << "after gas change at " << newGasEntry->sec << ": sensor pressure" << newGasEntry->pressure[0] << "interpolated" << newGasEntry->pressure[1]; - if (SENSOR_PRESSURE(gasChangeEntry) == 0 || displayed_dive.cylinder[gasChangeEntry->sensor[0]].sample_start.mbar == 0) { + if (get_plot_sensor_pressure(gasChangeEntry) == 0 || displayed_dive.cylinder[gasChangeEntry->sensor[0]].sample_start.mbar == 0) { // if we have no sensorpressure or if we have no pressure from samples we can assume that // we only have interpolated pressure (the pressure in the entry may be stored in the sensor // pressure field if this is the first or last entry for this tank... see details in gaspressures.c pressure_t pressure; - pressure.mbar = INTERPOLATED_PRESSURE(gasChangeEntry) ? : SENSOR_PRESSURE(gasChangeEntry); + pressure.mbar = get_plot_interpolated_pressure(gasChangeEntry) ? : get_plot_sensor_pressure(gasChangeEntry); QAction *adjustOldPressure = m.addAction(tr("Adjust pressure of cyl. %1 (currently interpolated as %2)") .arg(gasChangeEntry->sensor[0] + 1).arg(get_pressure_string(pressure))); } - if (SENSOR_PRESSURE(newGasEntry) == 0 || displayed_dive.cylinder[newGasEntry->sensor[0]].sample_start.mbar == 0) { + if (get_plot_sensor_pressure(newGasEntry) == 0 || displayed_dive.cylinder[newGasEntry->sensor[0]].sample_start.mbar == 0) { // we only have interpolated press -- see commend above pressure_t pressure; - pressure.mbar = INTERPOLATED_PRESSURE(newGasEntry) ? : SENSOR_PRESSURE(newGasEntry); + pressure.mbar = get_plot_interpolated_pressure(newGasEntry) ? : get_plot_sensor_pressure(newGasEntry); QAction *adjustOldPressure = m.addAction(tr("Adjust pressure of cyl. %1 (currently interpolated as %2)") .arg(newGasEntry->sensor[0] + 1).arg(get_pressure_string(pressure))); } |