summaryrefslogtreecommitdiffstats
path: root/profile-widget/profilewidget2.cpp
diff options
context:
space:
mode:
authorGravatar Berthold Stoeger <bstoeger@mail.tuwien.ac.at>2019-07-05 23:14:07 +0200
committerGravatar Dirk Hohndel <dirk@hohndel.org>2019-07-18 05:50:22 -0700
commit469cc68b029ac3308b4338a43acfa21679493e8b (patch)
tree110eaf78f7c1123784313009f2b8ee4844ec16f8 /profile-widget/profilewidget2.cpp
parent29005b578de4680556f6a3fa01781a8af842ced8 (diff)
downloadsubsurface-469cc68b029ac3308b4338a43acfa21679493e8b.tar.gz
Cleanup: replace pressure reading macros by inline functions
Replace the INTERPOLATED_PRESSURE and SENSOR_PRESSURE macros by inline functions. Generate a common inline function that reads a pressure value for a dynamic sensor. Not all SENSOR_PRESSURE macros can be replaced, because the macro is also used to set the value and C sadly doesn't know the concept of "return reference from a function". Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Diffstat (limited to 'profile-widget/profilewidget2.cpp')
-rw-r--r--profile-widget/profilewidget2.cpp8
1 files changed, 4 insertions, 4 deletions
diff --git a/profile-widget/profilewidget2.cpp b/profile-widget/profilewidget2.cpp
index f3cf31c50..6e311d117 100644
--- a/profile-widget/profilewidget2.cpp
+++ b/profile-widget/profilewidget2.cpp
@@ -1535,19 +1535,19 @@ void ProfileWidget2::contextMenuEvent(QContextMenuEvent *event)
if (gasChangeEntry + 1 <= plotInfo.entry + plotInfo.nr) {
newGasEntry = gasChangeEntry + 1;
qDebug() << "after gas change at " << newGasEntry->sec << ": sensor pressure" << newGasEntry->pressure[0] << "interpolated" << newGasEntry->pressure[1];
- if (SENSOR_PRESSURE(gasChangeEntry) == 0 || displayed_dive.cylinder[gasChangeEntry->sensor[0]].sample_start.mbar == 0) {
+ if (get_plot_sensor_pressure(gasChangeEntry) == 0 || displayed_dive.cylinder[gasChangeEntry->sensor[0]].sample_start.mbar == 0) {
// if we have no sensorpressure or if we have no pressure from samples we can assume that
// we only have interpolated pressure (the pressure in the entry may be stored in the sensor
// pressure field if this is the first or last entry for this tank... see details in gaspressures.c
pressure_t pressure;
- pressure.mbar = INTERPOLATED_PRESSURE(gasChangeEntry) ? : SENSOR_PRESSURE(gasChangeEntry);
+ pressure.mbar = get_plot_interpolated_pressure(gasChangeEntry) ? : get_plot_sensor_pressure(gasChangeEntry);
QAction *adjustOldPressure = m.addAction(tr("Adjust pressure of cyl. %1 (currently interpolated as %2)")
.arg(gasChangeEntry->sensor[0] + 1).arg(get_pressure_string(pressure)));
}
- if (SENSOR_PRESSURE(newGasEntry) == 0 || displayed_dive.cylinder[newGasEntry->sensor[0]].sample_start.mbar == 0) {
+ if (get_plot_sensor_pressure(newGasEntry) == 0 || displayed_dive.cylinder[newGasEntry->sensor[0]].sample_start.mbar == 0) {
// we only have interpolated press -- see commend above
pressure_t pressure;
- pressure.mbar = INTERPOLATED_PRESSURE(newGasEntry) ? : SENSOR_PRESSURE(newGasEntry);
+ pressure.mbar = get_plot_interpolated_pressure(newGasEntry) ? : get_plot_sensor_pressure(newGasEntry);
QAction *adjustOldPressure = m.addAction(tr("Adjust pressure of cyl. %1 (currently interpolated as %2)")
.arg(newGasEntry->sensor[0] + 1).arg(get_pressure_string(pressure)));
}