diff options
author | Robert C. Helling <helling@atdotde.de> | 2014-11-18 10:30:24 +0100 |
---|---|---|
committer | Dirk Hohndel <dirk@hohndel.org> | 2014-11-18 13:25:17 +0000 |
commit | 9561fa3f3ecd48be72cc6f4c325543031048218a (patch) | |
tree | 384a61db37e667e89f4104c65e82ff6f66c0da41 /profile.c | |
parent | 46acb24a865ba2029e15ad53066b28854b78074d (diff) | |
download | subsurface-9561fa3f3ecd48be72cc6f4c325543031048218a.tar.gz |
Cleaning up pressures
Added comment about meaning of o2pressure in struct plot_info.
Turned some pressures from double (in bar) to pressure_t (in mbar)
[Dirk Hohndel: picked parts of this patch and dropped others]
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Diffstat (limited to 'profile.c')
-rw-r--r-- | profile.c | 62 |
1 files changed, 29 insertions, 33 deletions
@@ -24,11 +24,6 @@ int selected_dive = -1; /* careful: 0 is a valid value */ unsigned int dc_number = 0; static struct plot_data *last_pi_entry_new = NULL; -double calculate_ccr_po2(struct plot_data *entry, struct divecomputer *dc); - -void fill_missing_segment_pressures(pr_track_t *); -struct pr_interpolate_struct get_pr_interpolate_data(pr_track_t *, struct plot_info *, int); -void fill_missing_tank_pressures(struct dive *, struct plot_info *, pr_track_t **, int); void populate_pressure_information(struct dive *, struct divecomputer *, struct plot_info *, int); #ifdef DEBUG_PI @@ -576,10 +571,10 @@ struct plot_data *populate_plot_entries(struct dive *dive, struct divecomputer * entry->in_deco = sample->in_deco; entry->cns = sample->cns; if (dc->dctype == CCR) { - entry->o2pressure = sample->setpoint.mbar / 1000.0; // for rebreathers - entry->o2sensor[0] = sample->o2sensor[0].mbar / 1000.0; // for up to three rebreather O2 sensors - entry->o2sensor[1] = sample->o2sensor[1].mbar / 1000.0; - entry->o2sensor[2] = sample->o2sensor[2].mbar / 1000.0; + entry->o2pressure.mbar = sample->setpoint.mbar; // for rebreathers + entry->o2sensor[0].mbar = sample->o2sensor[0].mbar; // for up to three rebreather O2 sensors + entry->o2sensor[1].mbar = sample->o2sensor[1].mbar; + entry->o2sensor[2].mbar = sample->o2sensor[2].mbar; } else { entry->pressures.o2 = sample->setpoint.mbar / 1000.0; } @@ -741,7 +736,7 @@ static void calculate_ndl_tts(double tissue_tolerance, struct plot_data *entry, while (entry->ndl_calc < max_ndl && deco_allowed_depth(tissue_tolerance, surface_pressure, dive, 1) <= 0) { entry->ndl_calc += time_stepsize; tissue_tolerance = add_segment(depth_to_mbar(entry->depth, dive) / 1000.0, - &dive->cylinder[cylinderindex].gasmix, time_stepsize, entry->o2pressure * 1000, dive, prefs.bottomsac); + &dive->cylinder[cylinderindex].gasmix, time_stepsize, entry->o2pressure.mbar , dive, prefs.bottomsac); } /* we don't need to calculate anything else */ return; @@ -753,7 +748,7 @@ static void calculate_ndl_tts(double tissue_tolerance, struct plot_data *entry, /* Add segments for movement to stopdepth */ for (; ascent_depth > next_stop; ascent_depth -= ascent_mm_per_step, entry->tts_calc += ascent_s_per_step) { tissue_tolerance = add_segment(depth_to_mbar(ascent_depth, dive) / 1000.0, - &dive->cylinder[cylinderindex].gasmix, ascent_s_per_step, entry->o2pressure * 1000, dive, prefs.decosac); + &dive->cylinder[cylinderindex].gasmix, ascent_s_per_step, entry->o2pressure.mbar , dive, prefs.decosac); next_stop = ROUND_UP(deco_allowed_depth(tissue_tolerance, surface_pressure, dive, 1), deco_stepsize); } ascent_depth = next_stop; @@ -771,13 +766,13 @@ static void calculate_ndl_tts(double tissue_tolerance, struct plot_data *entry, entry->tts_calc += time_stepsize; tissue_tolerance = add_segment(depth_to_mbar(ascent_depth, dive) / 1000.0, - &dive->cylinder[cylinderindex].gasmix, time_stepsize, entry->o2pressure * 1000, dive, prefs.decosac); + &dive->cylinder[cylinderindex].gasmix, time_stepsize, entry->o2pressure.mbar, dive, prefs.decosac); if (deco_allowed_depth(tissue_tolerance, surface_pressure, dive, 1) <= next_stop) { /* move to the next stop and add the travel between stops */ for (; ascent_depth > next_stop; ascent_depth -= ascent_mm_per_deco_step, entry->tts_calc += ascent_s_per_deco_step) add_segment(depth_to_mbar(ascent_depth, dive) / 1000.0, - &dive->cylinder[cylinderindex].gasmix, ascent_s_per_deco_step, entry->o2pressure * 1000, dive, prefs.decosac); + &dive->cylinder[cylinderindex].gasmix, ascent_s_per_deco_step, entry->o2pressure.mbar, dive, prefs.decosac); ascent_depth = next_stop; next_stop -= deco_stepsize; } @@ -805,7 +800,7 @@ void calculate_deco_information(struct dive *dive, struct divecomputer *dc, stru for (j = t0 + time_stepsize; j <= t1; j += time_stepsize) { int depth = interpolate(entry[-1].depth, entry[0].depth, j - t0, t1 - t0); double min_pressure = add_segment(depth_to_mbar(depth, dive) / 1000.0, - &dive->cylinder[entry->cylinderindex].gasmix, time_stepsize, entry->o2pressure * 1000, dive, entry->sac); + &dive->cylinder[entry->cylinderindex].gasmix, time_stepsize, entry->o2pressure.mbar, dive, entry->sac); tissue_tolerance = min_pressure; if (j - t0 < time_stepsize) time_stepsize = j - t0; @@ -856,21 +851,21 @@ void calculate_deco_information(struct dive *dive, struct divecomputer *dc, stru * calculates the po2 value from the sensor data. Several rules are applied, depending on how many o2 sensors * there are and the differences among the readings from these sensors. */ -double calculate_ccr_po2(struct plot_data *entry, struct divecomputer *dc) { - double sump = 0.0, minp = 999.9, maxp = -999.9; - double diff_limit = 100; // The limit beyond which O2 sensor differences are considered significant (default = 100 mbar) +static int calculate_ccr_po2(struct plot_data *entry, struct divecomputer *dc) { + int sump = 0, minp = 999999, maxp = -999999; + int diff_limit = 100; // The limit beyond which O2 sensor differences are considered significant (default = 100 mbar) int i, np = 0; for (i=0; i < dc->no_o2sensors; i++) - if (entry->o2sensor[i]) { // Valid reading + if (entry->o2sensor[i].mbar) { // Valid reading ++np; - sump += entry->o2sensor[i]; - minp = MIN(minp, entry->o2sensor[i]); - maxp = MAX(maxp, entry->o2sensor[i]); + sump += entry->o2sensor[i].mbar; + minp = MIN(minp, entry->o2sensor[i].mbar); + maxp = MAX(maxp, entry->o2sensor[i].mbar); } switch (np) { case 0: // Uhoh - return entry->o2pressure; + return entry->o2pressure.mbar / 1000.0; case 1: // Return what we have return sump; case 2: // Take the average @@ -889,7 +884,7 @@ double calculate_ccr_po2(struct plot_data *entry, struct divecomputer *dc) { } default: // This should not happen assert(np <= 3); - return 0.0; + return 0; } } @@ -905,7 +900,7 @@ static void calculate_gas_information_new(struct dive *dive, struct plot_info *p amb_pressure = depth_to_mbar(entry->depth, dive) / 1000.0; - fill_pressures(&entry->pressures, amb_pressure, &dive->cylinder[cylinderindex].gasmix, entry->o2pressure, dive->dc.dctype, entry->sac); + fill_pressures(&entry->pressures, amb_pressure, &dive->cylinder[cylinderindex].gasmix, entry->o2pressure.mbar / 1000.0, dive->dc.dctype, entry->sac); fn2 = (int) (1000.0 * entry->pressures.n2 / amb_pressure); fhe = (int) (1000.0 * entry->pressures.he / amb_pressure); @@ -944,26 +939,27 @@ void fill_o2_values(struct divecomputer *dc, struct plot_info *pi, struct dive * * for plotting. This function called by: create_plot_info_new() */ { int i, j; - double last_sensor[3], o2pressure, amb_pressure; + pressure_t last_sensor[3], o2pressure; + pressure_t amb_pressure; for (i = 0; i < pi->nr; i++) { struct plot_data *entry = pi->entry + i; if (dc->dctype == CCR) { if (i == 0) { // For 1st iteration, initialise the last_sensor values for (j = 0; j < dc->no_o2sensors; j++) - last_sensor[j] = pi->entry->o2sensor[j]; + last_sensor[j].mbar = pi->entry->o2sensor[j].mbar; } else { // Now re-insert the missing oxygen pressure values for (j = 0; j < dc->no_o2sensors; j++) - if (entry->o2sensor[j]) - last_sensor[j] = entry->o2sensor[j]; + if (entry->o2sensor[j].mbar) + last_sensor[j].mbar = entry->o2sensor[j].mbar; else - entry->o2sensor[j] = last_sensor[j]; + entry->o2sensor[j].mbar = last_sensor[j].mbar; } // having initialised the empty o2 sensor values for this point on the profile, - amb_pressure = depth_to_mbar(entry->depth, dive) / 1000.0; - o2pressure = calculate_ccr_po2(entry,dc); // ...calculate the po2 based on the sensor data - entry->o2pressure = MIN(o2pressure, amb_pressure); + amb_pressure.mbar = depth_to_mbar(entry->depth, dive); + o2pressure.mbar = calculate_ccr_po2(entry,dc); // ...calculate the po2 based on the sensor data + entry->o2pressure.mbar = MIN(o2pressure.mbar, amb_pressure.mbar); } else { - entry->o2pressure = 0.0; // initialise po2 to zero for dctype = OC + entry->o2pressure.mbar = 0; // initialise po2 to zero for dctype = OC } } } |