authorGravatar Dirk Hohndel <dirk@hohndel.org>2011-09-15 08:12:51 -0700
committerGravatar Linus Torvalds <torvalds@linux-foundation.org>2011-09-15 08:52:55 -0700
commitfa76733d255b32ecaabc600c8d582b8baa9d27c2 (patch)
tree9b155a2f4c895016f992dd39ae833e3296b1e9a4 /uemis.c
parent9ddef6854e8f54cd8d1431c15ba37c2c18d32ca7 (diff)
downloadsubsurface-fa76733d255b32ecaabc600c8d582b8baa9d27c2.tar.gz
Fix depth calculations in SDA import
stole and fixed Linus' code in the uemis XML importer Signed-off-by: Dirk Hohndel <dirk@hohndel.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'uemis.c')
-rw-r--r--uemis.c29
1 files changed, 27 insertions, 2 deletions
diff --git a/uemis.c b/uemis.c
index 7f431cba6..5cede0fac 100644
--- a/uemis.c
+++ b/uemis.c
@@ -134,6 +134,24 @@ int matchit(FILE *infd, char *regex, char *typeregex, char **found) {
return 0;
}
+/*
+ * pressure_to_depth: In centibar. And when converting to
+ * depth, I'm just going to always use saltwater, because I
+ * think "true depth" is just stupid. From a diving standpoint,
+ * "true depth" is pretty much completely pointless, unless
+ * you're doing some kind of underwater surveying work.
+ *
+ * So I give water depths in "pressure depth", always assuming
+ * salt water. So one atmosphere per 10m.
+ */
+static int pressure_to_depth(uint16_t value)
+{
+ double atm, cm;
+
+ atm = (value / 100.0) / 1.01325;
+ cm = 100 * atm + 0.5;
+ return( (cm > 0) ? 10 * (long)cm : 0);
+}
/*
* convert the base64 data blog
@@ -170,6 +188,7 @@ static void parse_divelog_binary(char *base64, struct dive **divep) {
int i;
uint8_t *data;
struct sample *sample;
+ struct dive *dive = *divep;
datalen = uemis_convert_base64(base64, &data);
@@ -177,15 +196,21 @@ static void parse_divelog_binary(char *base64, struct dive **divep) {
i = 0x123;
while ((i < datalen) && (*(uint16_t *)(data+i))) {
/* it seems that a dive_time of 0 indicates the end of the valid readings */
+ /* the SDA usually records more samples after the end of the dive --
+ * we want to discard those, but not cut the dive short; sadly the dive
+ * duration in the header is a) in minutes and b) up to 3 minutes short */
+ if (*(uint16_t *)(data+i) > dive->duration.seconds + 180)
+ break;
sample = prepare_sample(divep);
sample->time.seconds = *(uint16_t *)(data+i);
- sample->depth.mm = (*(uint16_t *)(data+i+2) - 100) / 0.101428571 + 0.5;
+ sample->depth.mm = pressure_to_depth(*(uint16_t *)(data+i+2));
sample->temperature.mkelvin = (*(uint16_t *)(data+i+4) * 100) + 273150;
sample->cylinderpressure.mbar= *(uint16_t *)(data+i+23) * 10;
sample->cylinderindex = *(uint8_t *)(data+i+22);
finish_sample(*divep, sample);
i += 0x25;
}
+ dive->duration.seconds = sample->time.seconds - 1;
return;
}
@@ -217,7 +242,7 @@ parse_uemis_file(char *divelogfilename,GError **error) {
/* some error handling */
goto bail;
}
- dive->maxdepth.mm = atof(found) / 0.10143 + 0.5;
+ dive->maxdepth.mm = pressure_to_depth(atoi(found));
if (! matchit(divelogfile,"<val key=\"file_content\">",
">\\([a-zA-Z0-9+/]*\\)<", &found)) {