diff options
-rw-r--r-- | dive.c | 22 |
1 files changed, 19 insertions, 3 deletions
@@ -883,12 +883,28 @@ void update_setpoint_events(struct divecomputer *dc) if (dc->divemode == CCR) new_setpoint = prefs.defaultsetpoint; - if (dc->divemode == OC) + if (dc->divemode == OC && same_string(dc->model, "Shearwater Predator")) { // make sure there's no setpoint in the samples // this is an irreversible change - so switching a dive to OC // by mistake when it's actually CCR is _bad_ - for (int i = 0; i < dc->samples; i++) - dc->sample[i].setpoint.mbar = 0; + // So we make sure, this comes from a Predator and we only remove + // pO2 values we would have computed anyway. + struct event *ev = get_next_event(dc->events, "gaschange"); + struct gasmix *gasmix = get_gasmix_from_event(ev); + struct event *next = get_next_event(ev, "gaschange"); + + for (int i = 0; i < dc->samples; i++) { + struct gas_pressures pressures; + if (next && dc->sample[i].time.seconds >= next->time.seconds) { + ev = next; + gasmix = get_gasmix_from_event(ev); + next = get_next_event(ev, "gaschange"); + } + fill_pressures(&pressures, calculate_depth_to_mbar(dc->sample[i].depth.mm, dc->surface_pressure, 0), gasmix ,0, OC); + if (abs(dc->sample[i].setpoint.mbar - (int)(1000 * pressures.o2) <= 50)) + dc->sample[i].setpoint.mbar = 0; + } + } // an "SP change" event at t=0 is currently our marker for OC vs CCR // this will need to change to a saner setup, but for now we can just |