diff options
-rw-r--r-- | uemis.c | 51 |
1 files changed, 38 insertions, 13 deletions
@@ -188,6 +188,8 @@ void uemis_set_divelocation(int divespot, char *text, double longitude, double l static void uemis_event(struct dive *dive, struct divecomputer *dc, struct sample *sample, uemis_sample_t *u_sample) { uint8_t *flags = u_sample->flags; + int stopdepth; + static int lastndl; if (flags[1] & 0x01) add_event(dc, sample->time.seconds, 0, 0, 0, N_("Safety Stop Violation")); @@ -232,22 +234,45 @@ static void uemis_event(struct dive *dive, struct divecomputer *dc, struct sampl /* flags[7] reflects the little on screen icons that remind of previous * warnings / alerts - not useful for events */ +#if UEMIS_DEBUG & 32 + int i, j; + for (i = 0; i < 8; i++) { + printf(" %d: ", 29 + i); + for (j = 7; j >= 0; j--) + printf ("%c", flags[i] & 1 << j ? '1' : '0'); + } + printf("\n"); +#endif /* now add deco / NDL - * This will create an event for every sample (SUCK) but the - * code in the parser will then do the right thing and just - * keep the relevant ones */ - if (u_sample->p_amb_tol > dive->surface_pressure.mbar) { - if (u_sample->hold_time && u_sample->hold_time < 99) { - int hold_depth = u_sample->hold_depth / 100.0 + 0.5; - add_event(dc, sample->time.seconds, SAMPLE_EVENT_DECOSTOP, 0, - hold_depth | (u_sample->hold_time * 60) << 16 , N_("deco stop")); - } -#if DC_VERSION_CHECK(0, 3, 0) + * we don't use events but store this in the sample - that makes much more sense + * for the way we display this information + * What we know about the encoding so far: + * flags[3].bit0 | flags[5].bit1 != 0 ==> in deco + * flags[0].bit7 == 1 ==> Safety Stop + * otherwise NDL */ + stopdepth = rel_mbar_to_depth(u_sample->hold_depth, dive); + if ((flags[3] & 1) | (flags[5] & 2)) { + /* deco */ + sample->stopdepth.mm = stopdepth; + sample->stoptime.seconds = u_sample->hold_time *60; + sample->ndl.seconds = 0; + } else if (flags[0] & 128) { + /* safety stop - distinguished from deco stop by having + * both ndl and stop information */ + sample->stopdepth.mm = stopdepth; + sample->stoptime.seconds = u_sample->hold_time *60; + sample->ndl.seconds = lastndl; } else { - add_event(dc, sample->time.seconds, SAMPLE_EVENT_NDL, 0, - u_sample->hold_time * 60, N_("non stop time")); -#endif + /* NDL */ + lastndl = sample->ndl.seconds = u_sample->hold_time *60; + sample->stopdepth.mm = 0; + sample->stoptime.seconds = 0; } +#if UEMIS_DEBUG & 32 + printf("%dm:%ds: p_amb_tol:%d surface:%d holdtime:%d holddepth:%d/%d ---> stopdepth:%d stoptime:%d ndl:%d\n", + sample->time.seconds / 60, sample->time.seconds % 60, u_sample->p_amb_tol, dive->surface_pressure.mbar, + u_sample->hold_time, u_sample->hold_depth, stopdepth, sample->stopdepth.mm, sample->stoptime.seconds, sample->ndl.seconds); +#endif } /* |