aboutsummaryrefslogtreecommitdiffstats
path: root/Documentation/user-manual.txt
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/user-manual.txt')
-rw-r--r--Documentation/user-manual.txt39
1 files changed, 24 insertions, 15 deletions
diff --git a/Documentation/user-manual.txt b/Documentation/user-manual.txt
index 6ce4921f7..6490c9c32 100644
--- a/Documentation/user-manual.txt
+++ b/Documentation/user-manual.txt
@@ -6,7 +6,7 @@
// :revnumber: 4.5
// :revdate: October 2015
:icons:
-:toc:
+:toc2:
:toc-placement: manual
:numbered:
// :website: http://subsurface-divelog.org
@@ -71,10 +71,10 @@ When opened from within _Subsurface_, this manual does not have external control
paging or selecting previous pages. However, two facilities are provided:
- The _SEARCH_ function is activated by pressing control-F or command-F on
-the keyboard. A text box appears at the bottom right-handof the window (see image below).
+the keyboard. A text box appears at the bottom right-hand of the window (see image below).
For instance, if one typed the word "_weights_" into the search text box, this word will
be searched for throughout this user manual. To the right of the search text box are two arrows pointing
-up and down. Selecting these allow finding, respectively, the previous and the next occurence of
+upwards and downwards. Selecting these allow finding, respectively, the previous and the next occurence of
the term being searched for.
image::images/usermanualfunctions.jpg["User manual functions",align="center"]
@@ -85,9 +85,9 @@ jump to specific sections in this user manual) by right-clicking on the text of
This brings up a context menu for jumping to previous links selected while reading the manual
(see image above). For instance if a link in the manual has been selected, then the option
to _Go Back_ shows the text at the last link that was selected (similar to the Previous Page
-button in most web browsers). Conversely the _Go Forward_ option enables jumping to the
+button in a browser). Conversely the _Go Forward_ option enables jumping to the
text perused before selecting the _Go Back_ option. The _Reload_ option causes the complete
-user manual to be reladed into the user manual window.
+user manual to be reloaded into the user manual window.
[[S_UserSurvey]]
The user survey
@@ -532,7 +532,11 @@ The label of the discovered dive computer contains the name of the device, its
address and its pairing status. If the device is not paired and has a red
background colour, a context menu can be opened by selecting the item with a
right-click.
-Select the the _Pair_ option and wait for the task to complete.
+Select the the _Pair_ option and wait for the task to complete. If this dive computer
+is being paired to Subsurface for the first time, it is possible that Subsurface will
+request a Pass Code or PIN number. The most commonly-used Pass Code is 0000,
+and this works for the Shearwater Petrel. If necessary, consult the user manual of the
+dive computer being used.
****
[icon="images/icons/important.png"]
@@ -563,9 +567,14 @@ shown on the righthand side of the download dialogue.
===== On Windows:
image::images/DC_import_Bluetooth_Windows.png["FIGURE: Download Bluetooth on Windows",align="center"]
-On _Windows_ platforms the _Local Bluetooth device details section_ on the right is not displayed.
+On _Windows_ platforms the _Local Bluetooth device details section_ on the right is not displayed as
+is the case on the Linux/Mac implementations.
To successfully initiate a scan (by pressing the _Scan_ button)
-check that the Bluetooth device on the _Subsurface_ computer is turned on.
+check that the Bluetooth device on the _Subsurface_ computer is turned on by selecting
+the dive computer from the list of available Bluetooth devices (see image above). If the dive computer
+is accessed by Subsurface for the first time, it is possible that Subsurface will
+request a Pass Code/PIN number. Supply the Pass Code recommended in the user manual of the dive computer.
+A Pass Code of 0000 is often appropriate.
The pairing step is checked and done automatically during
the download process. If the devices have never been paired the system will ask
@@ -576,11 +585,11 @@ Finally select the _Download_ button on the _Download_ dialogue and wait for the
[icon="images/icons/important.png"]
[IMPORTANT]
-Be aware that currently _Subsurface_ works only with local Bluetooth
+Currently _Subsurface_ works only with local Bluetooth
adapters which use Microsoft Bluetooth Stack. If the local device uses
-_Widcomm_, _Stonestreet One Bluetopia Bluetooth_ or _BlueSolei_ drivers it
-will definitely not work.
-
+_Widcomm_, _Stonestreet One Bluetopia Bluetooth_ or _BlueSoleil_ drivers it
+will definitely not work. However, Bluetooth hardware/dongles from these manufacturers
+(e.g. iSonic) that support the Microsoft Bluetooth Stack do work.
A log messageOn the bottom left of the _Remote Bluetooth device selection_
shows details about the current status of the Bluetooth agent. To
@@ -3597,7 +3606,7 @@ dives.
[icon="images/icons/bluetooth.jpg"]
[NOTE]
For dive computers communicating through Bluetooth like the Heinrichs
-Weikamp Frog or the Shearwater Predator, Petrel, and Nerd there is a
+Weikamp Frog or the Shearwater Predator, Petrel and Nerd there is a
different procedure to get the devices name to communicate with
_Subsurface_. Follow these steps:
@@ -3651,7 +3660,7 @@ It is essentially a three step process.
- Establish an RFCOMM connection
- Download the dives with Subsurface
-Ensure the dive computer is in upload mode. On the _Shearwater Petrel_, _Petrel 2_, and _Nerd_
+Ensure the dive computer is in upload mode. On the _Shearwater Petrel_, _Petrel 2_ and _Nerd_
cycle through the menu, select 'Dive Log', then 'Upload Log'. The display will read 'Initializing', then
'Wait PC 3:00' and will countdown. Once the connection is established, the display reads 'Wait CMD ...'
and the countdown continues. When downloading the dive from Subsurface, the display reads 'Sending' then
@@ -3753,9 +3762,9 @@ The command to establish an RFCOMM connection is:
If one omits it, channel 1 is assumed. Based on a limited number of user reports,
the appropriate channel for the dive computer is probably:
+- _Shearwater Petrel 1_: channel 1
- _Shearwater Petrel 2_: channel 5
- _Shearwater Nerd_: channel 5
-- _Shearwater Petrel 1_: channel 1
- _Heinrichs-Weikamp OSTC Sport_: channel 1
E.g. to connect a _Shearwater Petrel 2_, set the dive computer to upload mode and enter: