diff options
Diffstat (limited to 'core/equipment.c')
-rw-r--r-- | core/equipment.c | 166 |
1 files changed, 91 insertions, 75 deletions
diff --git a/core/equipment.c b/core/equipment.c index 2fab787eb..bdecbb3f7 100644 --- a/core/equipment.c +++ b/core/equipment.c @@ -51,6 +51,11 @@ void copy_cylinders(const struct cylinder_table *s, struct cylinder_table *d) add_cloned_cylinder(d, s->cylinders[i]); } +static void free_tank_info(struct tank_info info) +{ + free((void *)info.name); +} + /* weightsystem table functions */ //static MAKE_GET_IDX(weightsystem_table, weightsystem_t, weightsystems) static MAKE_GROW_TABLE(weightsystem_table, weightsystem_t, weightsystems) @@ -71,6 +76,12 @@ static MAKE_REMOVE_FROM(cylinder_table, cylinders) //MAKE_REMOVE(cylinder_table, cylinder_t, cylinder) MAKE_CLEAR_TABLE(cylinder_table, cylinders, cylinder) +/* tank_info table functions */ +static MAKE_GROW_TABLE(tank_info_table, tank_info_t, infos) +static MAKE_ADD_TO(tank_info_table, tank_info_t, infos) +//static MAKE_REMOVE_FROM(tank_info_table, infos) +MAKE_CLEAR_TABLE(tank_info_table, infos, tank_info) + const char *cylinderuse_text[NUM_GAS_USE] = { QT_TRANSLATE_NOOP("gettextFromC", "OC-gas"), QT_TRANSLATE_NOOP("gettextFromC", "diluent"), QT_TRANSLATE_NOOP("gettextFromC", "oxygen"), QT_TRANSLATE_NOOP("gettextFromC", "not used") }; @@ -84,25 +95,32 @@ int cylinderuse_from_text(const char *text) return -1; } +/* Add a metric or an imperial tank info structure. Copies the passed-in string. */ +void add_tank_info_metric(struct tank_info_table *table, const char *name, int ml, int bar) +{ + struct tank_info info = { strdup(name), .ml = ml, .bar = bar }; + add_to_tank_info_table(table, table->nr, info); +} + +void add_tank_info_imperial(struct tank_info_table *table, const char *name, int cuft, int psi) +{ + struct tank_info info = { strdup(name), .cuft = cuft, .psi = psi }; + add_to_tank_info_table(table, table->nr, info); +} + /* placeholders for a few functions that we need to redesign for the Qt UI */ void add_cylinder_description(const cylinder_type_t *type) { - const char *desc; - int i; - - desc = type->description; - if (!desc) + const char *desc = type->description; + if (empty_string(desc)) return; - for (i = 0; i < MAX_TANK_INFO && tank_info[i].name != NULL; i++) { - if (strcmp(tank_info[i].name, desc) == 0) + for (int i = 0; i < tank_info_table.nr; i++) { + if (strcmp(tank_info_table.infos[i].name, desc) == 0) return; } - if (i < MAX_TANK_INFO) { - // FIXME: leaked on exit - tank_info[i].name = strdup(desc); - tank_info[i].ml = type->size.mliter; - tank_info[i].bar = type->workingpressure.mbar / 1000; - } + // FIXME: leaked on exit + add_tank_info_metric(&tank_info_table, desc, type->size.mliter, + type->workingpressure.mbar / 1000); } void add_weightsystem_description(const weightsystem_t *weightsystem) @@ -229,62 +247,63 @@ int find_best_gasmix_match(struct gasmix mix, const struct cylinder_table *cylin * we should pick up any other names from the dive * logs directly. */ -struct tank_info_t tank_info[MAX_TANK_INFO] = { +struct tank_info_table tank_info_table; +void reset_tank_info_table(struct tank_info_table *table) +{ + clear_tank_info_table(table); + /* Need an empty entry for the no-cylinder case */ - { "", }, + add_tank_info_metric(table, "", 0, 0); /* Size-only metric cylinders */ - { "10.0ℓ", .ml = 10000 }, - { "11.1ℓ", .ml = 11100 }, + add_tank_info_metric(table, "10.0ℓ", 10000, 0); + add_tank_info_metric(table, "11.1ℓ", 11100, 0); /* Most common AL cylinders */ - { "AL40", .cuft = 40, .psi = 3000 }, - { "AL50", .cuft = 50, .psi = 3000 }, - { "AL63", .cuft = 63, .psi = 3000 }, - { "AL72", .cuft = 72, .psi = 3000 }, - { "AL80", .cuft = 80, .psi = 3000 }, - { "AL100", .cuft = 100, .psi = 3300 }, + add_tank_info_metric(table, "AL40", 40, 3000); + add_tank_info_metric(table, "AL50", 50, 3000); + add_tank_info_metric(table, "AL63", 63, 3000); + add_tank_info_metric(table, "AL72", 72, 3000); + add_tank_info_metric(table, "AL80", 80, 3000); + add_tank_info_metric(table, "AL100", 100, 3300); /* Metric AL cylinders */ - { "ALU7", .ml = 7000, .bar = 200 }, + add_tank_info_metric(table, "ALU7", 7000, 200); /* Somewhat common LP steel cylinders */ - { "LP85", .cuft = 85, .psi = 2640 }, - { "LP95", .cuft = 95, .psi = 2640 }, - { "LP108", .cuft = 108, .psi = 2640 }, - { "LP121", .cuft = 121, .psi = 2640 }, + add_tank_info_imperial(table, "LP85", 85, 2640); + add_tank_info_imperial(table, "LP95", 95, 2640); + add_tank_info_imperial(table, "LP108", 108, 2640); + add_tank_info_imperial(table, "LP121", 121, 2640); /* Somewhat common HP steel cylinders */ - { "HP65", .cuft = 65, .psi = 3442 }, - { "HP80", .cuft = 80, .psi = 3442 }, - { "HP100", .cuft = 100, .psi = 3442 }, - { "HP117", .cuft = 117, .psi = 3442 }, - { "HP119", .cuft = 119, .psi = 3442 }, - { "HP130", .cuft = 130, .psi = 3442 }, + add_tank_info_imperial(table, "HP65", 65, 3442); + add_tank_info_imperial(table, "HP80", 80, 3442); + add_tank_info_imperial(table, "HP100", 100, 3442); + add_tank_info_imperial(table, "HP117", 117, 3442); + add_tank_info_imperial(table, "HP119", 119, 3442); + add_tank_info_imperial(table, "HP130", 130, 3442); /* Common European steel cylinders */ - { "3ℓ 232 bar", .ml = 3000, .bar = 232 }, - { "3ℓ 300 bar", .ml = 3000, .bar = 300 }, - { "10ℓ 200 bar", .ml = 10000, .bar = 200 }, - { "10ℓ 232 bar", .ml = 10000, .bar = 232 }, - { "10ℓ 300 bar", .ml = 10000, .bar = 300 }, - { "12ℓ 200 bar", .ml = 12000, .bar = 200 }, - { "12ℓ 232 bar", .ml = 12000, .bar = 232 }, - { "12ℓ 300 bar", .ml = 12000, .bar = 300 }, - { "15ℓ 200 bar", .ml = 15000, .bar = 200 }, - { "15ℓ 232 bar", .ml = 15000, .bar = 232 }, - { "D7 300 bar", .ml = 14000, .bar = 300 }, - { "D8.5 232 bar", .ml = 17000, .bar = 232 }, - { "D12 232 bar", .ml = 24000, .bar = 232 }, - { "D13 232 bar", .ml = 26000, .bar = 232 }, - { "D15 232 bar", .ml = 30000, .bar = 232 }, - { "D16 232 bar", .ml = 32000, .bar = 232 }, - { "D18 232 bar", .ml = 36000, .bar = 232 }, - { "D20 232 bar", .ml = 40000, .bar = 232 }, - - /* We'll fill in more from the dive log dynamically */ - { NULL, } -}; + add_tank_info_metric(table, "3ℓ 232 bar", 3000, 232); + add_tank_info_metric(table, "3ℓ 300 bar", 3000, 300); + add_tank_info_metric(table, "10ℓ 200 bar", 10000, 200); + add_tank_info_metric(table, "10ℓ 232 bar", 10000, 232); + add_tank_info_metric(table, "10ℓ 300 bar", 10000, 300); + add_tank_info_metric(table, "12ℓ 200 bar", 12000, 200); + add_tank_info_metric(table, "12ℓ 232 bar", 12000, 232); + add_tank_info_metric(table, "12ℓ 300 bar", 12000, 300); + add_tank_info_metric(table, "15ℓ 200 bar", 15000, 200); + add_tank_info_metric(table, "15ℓ 232 bar", 15000, 232); + add_tank_info_metric(table, "D7 300 bar", 14000, 300); + add_tank_info_metric(table, "D8.5 232 bar", 17000, 232); + add_tank_info_metric(table, "D12 232 bar", 24000, 232); + add_tank_info_metric(table, "D13 232 bar", 26000, 232); + add_tank_info_metric(table, "D15 232 bar", 30000, 232); + add_tank_info_metric(table, "D16 232 bar", 32000, 232); + add_tank_info_metric(table, "D18 232 bar", 36000, 232); + add_tank_info_metric(table, "D20 232 bar", 40000, 232); +} /* * We hardcode the most common weight system types @@ -402,30 +421,27 @@ cylinder_t *get_or_create_cylinder(struct dive *d, int idx) void fill_default_cylinder(const struct dive *dive, cylinder_t *cyl) { const char *cyl_name = prefs.default_cylinder; - struct tank_info_t *ti = tank_info; pressure_t pO2 = {.mbar = lrint(prefs.modpO2 * 1000.0)}; if (!cyl_name) return; - while (ti->name != NULL && ti < tank_info + MAX_TANK_INFO) { - if (strcmp(ti->name, cyl_name) == 0) - break; - ti++; - } - if (ti->name == NULL) - /* didn't find it */ - return; - cyl->type.description = strdup(ti->name); - if (ti->ml) { - cyl->type.size.mliter = ti->ml; - cyl->type.workingpressure.mbar = ti->bar * 1000; - } else { - cyl->type.workingpressure.mbar = psi_to_mbar(ti->psi); - if (ti->psi) - cyl->type.size.mliter = lrint(cuft_to_l(ti->cuft) * 1000 / bar_to_atm(psi_to_bar(ti->psi))); + for (int i = 0; i < tank_info_table.nr; ++i) { + struct tank_info *ti = &tank_info_table.infos[i]; + if (strcmp(ti->name, cyl_name) == 0) { + cyl->type.description = strdup(ti->name); + if (ti->ml) { + cyl->type.size.mliter = ti->ml; + cyl->type.workingpressure.mbar = ti->bar * 1000; + } else { + cyl->type.workingpressure.mbar = psi_to_mbar(ti->psi); + if (ti->psi) + cyl->type.size.mliter = lrint(cuft_to_l(ti->cuft) * 1000 / bar_to_atm(psi_to_bar(ti->psi))); + } + // MOD of air + cyl->depth = gas_mod(cyl->gasmix, pO2, dive, 1); + return; + } } - // MOD of air - cyl->depth = gas_mod(cyl->gasmix, pO2, dive, 1); } cylinder_t create_new_cylinder(const struct dive *d) |