2014-11-19Document more about fields in Poseidon MkVI logsGravatar Anton Lundin
This is based on the great work done by Søren Reinke's on his MKVI Logfile Analyzer. Signed-off-by: Anton Lundin <glance@acc.umu.se> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Create more events from Poseidon MkVI logsGravatar Anton Lundin
This is based on the great work done by Søren Reinke's on his MKVI Logfile Analyzer. Signed-off-by: Anton Lundin <glance@acc.umu.se> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Create gaschange events from Poseidon MkVI logsGravatar Anton Lundin
This is based on the great work done by Søren Reinke's on his MKVI Logfile Analyzer. Signed-off-by: Anton Lundin <glance@acc.umu.se> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Create events from mouthpiece positionGravatar Anton Lundin
This is based on the great work done by Søren Reinke's on his MKVI Logfile Analyzer. Signed-off-by: Anton Lundin <glance@acc.umu.se> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Add support for importing CEILING from MKVI logsGravatar Anton Lundin
This is based on the great work done by Søren Reinke's on his MKVI Logfile Analyzer. Signed-off-by: Anton Lundin <glance@acc.umu.se> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Import NDL from Poseidon MKVI logsGravatar Anton Lundin
This is based on the great work done by Søren Reinke's on his MKVI Logfile Analyzer. Signed-off-by: Anton Lundin <glance@acc.umu.se> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Profile: adjust tank pressures at gas change (incomplete)Gravatar Dirk Hohndel
This code sets up the UI that will allow the user to adjust tank pressures at a gaschange event. The actual changing of the pressure is not implemented, yet, so this is disabled until someone finds time to do so. The scenario is this: a tec diver or sidemount diver without pressure sensors on at least one of their tanks still wants to reasonably accurately track gas consumption during a dive. The diver takes notes of the pressures at every tank switch (I find that odd, but apparently some cave divers indeed do that as they switch back and forth between different gases) and then wants to adjust the pressures in Subsurface to match those written down. One difficulty here is that the first and last pressure of a tank with no sensor data is still considered "sensor pressure" - this is basically an implementation detail in the code that is used to do the pressure interpolation to have constant-SAC pressure plots for tanks without sensors. So when we check if there is indeed no pressure data available at the gas change, we can't just work with the interpolated pressure - if this is the first (or last) time the tank was used, that pressure may be marked as sensor pressure. What's missing is the UI to enter the desired new pressure plus the black magic that actually inserts this into the dive in a way that doesn't break the assumptions in the rest of the code. I'm running out of time to do that but wanted to preserve this code so someone can continue this later. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Profile: don't offer to switch to an already active tankGravatar Dirk Hohndel
Adding a gas change to tank that we are already breathing from makes no sense, so let's not offer this. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Profile: add helper function to get the sample entry for a mouse positionGravatar Dirk Hohndel
This seems quite useful to have. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Profile: keep the plotInfo in the corresponding member variableGravatar Dirk Hohndel
We had the variable. As a pointer. Which we used memset to clear. Ouch - that smells like some bad cut and paste. With this change the object keeps the corresponding plotInfo around (just like some others do) and can use it later. I suspect this code could use some larger cleanup, but it's a bit too late for this in the development cycle, I guess. I'm sure I'll regret this in the future... Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Don't offer to add a gas change if there is ony one gasGravatar Dirk Hohndel
In the context menu of the profile it makes no sense to offer the ability to switch gases unless there is a gas to switch to. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-19Update spanish translation of user manual to english e0c9ebfGravatar Salvador Cuñat
Includes the dive list filters and modifications on tissues graph. Corrects a typpo. Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Cleaning up pressuresGravatar Robert C. Helling
Added comment about meaning of o2pressure in struct plot_info. Turned some pressures from double (in bar) to pressure_t (in mbar) [Dirk Hohndel: picked parts of this patch and dropped others] Signed-off-by: Robert C. Helling <helling@atdotde.de> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Update todo list for CCRGravatar willem ferguson
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Replace other references to hohndel.orgGravatar Dirk Hohndel
The only place where I'm not sure if there are unintended sideeffects of changing over to the new domain is QCoreApplication::setOrganizationDomain Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Move update check and survey to the new domainGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Fix issues in CCR handlingGravatar willem ferguson
In commit 0d7c192e6edc ("For CCR dives, the diluent cylinder is the current cylinder") a few things got broken. This tries to undo those changes and adds expanded XML output. 1) Calculate correct partial pressure of oxygen to be plotted on dive profile, taking into account the oxygen sensor data. Currently, erroneously, OC PO2 values are shown, due to an erroneous calling parameter to fill_pressures(). 2) Read start and end cylinder pressured correctly. some wrong assignments were done in file.c. This is now corrected and the correct cylinder pressures are shown in the equipment tab. 3) Write correct cylinder pressures to XML. Currently the data for the two cylinders are written to XML the wrong way round (diluent pressures = oxygen and vice versa). 4) Expand XML output: a) Write oxygen sensor data to XML b) Write no_of_02sensors to XML Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Fix crash when opening Poseidon_MkVILog.xmlGravatar Dirk Hohndel
In commit d5d7fdc9af98 ("For CCR dives, show plot for diluent and O2 cylinder pressures") we end up dereferencing current before it is first initialized. Bad. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Remove unused variablesGravatar Miika Turkia
Signed-off-by: Miika Turkia <miika.turkia@gmail.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Limit pressure and temperature valuesGravatar Miika Turkia
Limit temperatures and cylinder pressures to somewhat sensible values. Signed-off-by: Miika Turkia <miika.turkia@gmail.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-18Don't use DC configuration menu item as preference dialog on MacGravatar Dirk Hohndel
Qt by default uses a rather simplistic text heuristic to figure out if a menu entry is one of the special ones that need to be moved into the application menu (About, Preferences, Quit - but for Preferences anything that matches settings, options, config is used as well). This patch tells Qt to keep its hands off the the DC configuration entry in the menu. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Add new divecomputers to the ReleaseNotesGravatar Dirk Hohndel
Of course AFTER cutting Beta 1. Typical. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Preparing for 4.3 Beta 1v4.2.90Gravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Latest translationsGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Only show tags in filter panel that are actually usedGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Ruler: fix weird behaviour near x = 0Gravatar Lubomir I. Ivanov
RulerNodeItem2::recalculate() does something which is apparently not a good idea in combination with RulerNodeItem2::mouseMoveEvent(). Each time the mouse moves, setPos() is called. Then in recalculate() the x() value is checked and if less than 0 it's changed to x = 0 (setPos(0, y());). This last call (setPos(0, y());) however does not work and the value remains less than zero leaving one of the ruler points outside of the graph. To solve the issue we add a silly explicit check if x() < 0 before calling setPos() in RulerNodeItem2::mouseMoveEvent(). The 'x() > timeAxis->posAtValue(data->sec)' strangely works on the other hand. Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Update ReleaseNotesGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Updated the included user manual html filesGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Latest strings and translationsGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Clarify the meaning of the values in the stats tabGravatar Dirk Hohndel
Extend the tooltips to be shown both on the labels and the values and add tooltips for all min/avg/max elements. To avoid confusion when only one dive is selected, no longer show min SAC or max SAC or min duration or max duration. Fixes #694 Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Clean up yearly statisticsGravatar Dirk Hohndel
Remove the unused upper widget, set a somewhat random but at least more reasonable default size and finally support Ctrl-W and Ctrl-Q shortcuts. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17For CCR dives, show plot for diluent and O2 cylinder pressuresGravatar Robert C. Helling
Also fixes a bug in the diluent pressure interpolation Signed-off-by: Robert C. Helling <helling@atdotde.de> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Update spanish translation of user manual to english 7967d2bGravatar Salvador Cuñat
Covers CCR APD and Poseidon divelogs and importing. Already changed by the time of writing this commit, at least twice. Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Update spanish translation of user manual to english 08adb2eGravatar Salvador Cuñat
Somehow I forgot to submit this back in October. Includes the gases pressures bar graph. Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17New strings (and updated translations)Gravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Allow translation of the cylinder use strings for the UIGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Add the ability to modify the cylinder use in the UIGravatar Dirk Hohndel
Thanks to Tomaz for writing a first draft of the delegate. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Use cylinder use helper functionGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Add helper function to translate cylinder use text to matching idxGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17For CCR dives, the diluent cylinder is the current cylinderGravatar Robert C. Helling
Change the meaning that _the_ cylinder (as we treat it in OC dives) is the diluent cylinder (rather than the O2 cylinder). This eliminates special cases. Now, for CCR, we have to handle the O2 cylinder in addition (rather than the diluent in addition). Signed-off-by: Robert C. Helling <helling@atdotde.de> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Continue cleanup of string copying in equipmentGravatar Dirk Hohndel
Slowly trying to track down all spots where we copy string pointers instead of string data. And making sure that we free those pointers before overwriting them. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17When editing cylinders, copy all relevant dataGravatar Dirk Hohndel
Maybe it would be better to just copy the whole structure and then clear the things we don't want to copy? This seems fragile. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Correctly copy weight systems on editGravatar Dirk Hohndel
We copied the string pointers instead of copying the strings. Once those got freed, things went downhill. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Small modification of the filter descriptionGravatar Dirk Hohndel
This seems more important to explain - it's OR within the column and AND between the columns. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17User manual: text to explain filter panelGravatar Willem Ferguson
Few smaller changes to text dealing with tissue pressures graph Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17More CCR code cleanupGravatar Dirk Hohndel
Random constants are bad. Let's use the indices that we already calculated (and true and false if we mean boolean values). Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Update ReleaseNotes.txtGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17727 fixedGravatar Tomaz Canabrava
--047d7b8737f87ede8e050803e6b2 Content-Type: text/plain; charset=UTF-8 <div dir="ltr"><br></div> From 3db4a422485374801ca2f6233ec23b8671a8656d Mon Sep 17 00:00:00 2001 From: Tomaz Canabrava <tomaz.canabrava@intel.com> Date: Sun, 16 Nov 2014 23:22:58 -0200 Subject: [PATCH] fix 727 - position correctly the popup. When the user entered a tag and that made the message box display the popup with the possible choices was still in the old position hidding the line edit. Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17Add a TODO.CCR file to track what's left to do for CCR supportGravatar Dirk Hohndel
These are the things I ran into today. I'm sure there are many, many more. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2014-11-17CCR test diveGravatar Dirk Hohndel
This is an anonymized version of a real dive. With the latest changes the SAC calculations now make "mostly sense". What's clearly still broken is the tank pressure graph. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>