Age | Commit message (Collapse) | Author |
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
If the element we are parsing is of type XML_CDATA_SECTION_NODE, we have
to check the node's name from the parent.
Fixes #718
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This creates a delegate to simplify the handling of gas components and
the change depth.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This creates a delegate for the type column to choose the type value for
gases that is less confusing then the raw value.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
I fixed up the decode and finished the parse for Cochran EMC, Commander
and Gemini computers. I suspect that this code may only work with files
from certain versions of Cochran Analyst. It works with my own CAN files
and with the samples that came with Analyst v4.01v.
A seemingly arbitrary offset of 0x4914 is needed to access data.
The previous code uses 0x4a14 and 0x4b14. I suspect these are from
different version of Analyst.
[Dirk Hohndel: whitespace cleanup, add files to subsurface.pro, made sure
this compiles without the corresponding patch to
libdivecomputer (that isn't upstream, yet), cleaned up the
usage of structs, removed a few unused variables]
Signed-off-by: John Van Ostrand <john@vanostrand.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This adds code that writes configuration data to the OSTC. As we don't
look at all the values in the OSTC config blocks, we read the current
blocks and only change the values we can change.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This code is to debug the rest of the existing CF's, so we can look at
the rest of the values.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This adds code to decode the custom functions data.
We only decode the relevant CF's. The relevant ones are chosen by which
ones have corresponding settings in the OSTC3.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This adds code to decode the configuration blocks from the OSTC.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This adds debug code to simulate the read and write to OSTC memory
dumps.
The OSTC configuration happens via writing whole 512 byte blocks to the
memory and this code is useful when debugging that process
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
On the OSTC's the salinity is in kg/l and is stored as kg/l * 100
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
The OSTC supports a bit different functionalities than the OSTC3 does.
The "unsupported" bits are
setBrightness
setCalibrationGas
setCompassGain
setDiveMode - Bult into setDecoType (OC/CCR)
setDiveModeColor - Lots of different colors
setFlipScreen
setLanguage - Controlled via flashing different firmwares
setPressureSensorOffset
setUnits
setSetPointFallback
setCcrMode - there are some ppO2 reading functionality in the fist gen
OSTC that we don't care about, and the rest is controlled
via choosing a CCR deco algorithm
Also the OSTC have a notion of number of dives it has done, so this adds
ui for that value.
There are also differences in how some values are handled. Ex the OSTC
don't have fixed samplerates that you can choose between. You can rather
just set your sample rate to X seconds.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Just renumber the ui components. _3 for OSTC.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
The problem that we were comparing signed and unsigned ints was originally
found by Lubomir. As image times can be negative (and the comparison should
fail in that case) we need to compared them as signed.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Acked-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This cleans up some styling and syntax in the Configure Dive Computer
code path.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
The icon comes from heinrichsweikamp.com, the same as the ostc3.png did.
I've emailed with Matthias Heinrichs at HW and they have given us
permission to use both the ostc3.png and ostc2n.png under the GPL v2.
They also can provide the hi-res originals if anyone needs to do more
work on these icons.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
We now include the Ui header file, so we can remove the forward
declaration.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
The device supports a up to 60 chars custom text. This limits the
LineEdit to that amount, so users see when they reach the max limit.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This adds a shortcut, Ctrl+Shift+C to jump into the Configure dive computer
dialog.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
In commit a85a219df325 ("Add ability to replan a dive that we planned
before") I completely mishandled the saving of the replanned data.
How embarrassing.
Fixes #747
See #527
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Since the setpoint value is initialized as zero, we have to set the
previous value if we do not have a current reading.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
We cannot zero setpoint value upon import if the current and previous
values are zero. This is because on setpoint context a value of 0 means
open circuit.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Not used on other OS and triggers a warning.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
fill_o2_values():
struct gas_pressures *pressures;
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
DiveLogExportDialog::export_depths()
We set a default value of 'unit' which will silence the warning itself.
Then hope that the compiler will respect the argument order i.e. call
get_depth_units() (which sets 'unit') before using *unit as the last
argument passsed to put_format().
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Make eventFilter() return a value for NO_MARBLE.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
"gridLayout_1" is used twice. Re-order the grid layouts as 1, 2, 3.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
MainWindow::on_actionReplanDive_triggered():
If a dive in the divelist does not have a "DC Model" for some reason,
selecting "re-plan" from the menu will pass a NULL value
current_dive->dc.model to strcmp() and break before the debug output.
To fix that we check if the said .model value is NULL.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Addresses a warning, but also seems more correct.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This patch adds support for importing the logs from a Poseidon MK6
rebreather. This DC produces logs that contain of a .txt file that has
all the meta data and a .csv file that contains the sample readings. The
CSV file is different from the others in that it has a line per each
sample reading at given time. Thus we have to merge all the lines from
one point in time into one sample reading of ours.
[Dirk Hohndel: addressed some compiler warnings]
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
In the transition to the partial pressure helper function,
the water vapor component of the breathing gas had been dropped.
This had a significant effect on deco times for deep dives.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This reports back a error to the user if the firmware update failed.
We should re-wire this to have a log-function that gets called from
libdivecomputer via the context to get an actual error message.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This fixes a copy-paste error, dereferencing the wrong pointer in the
slot that gets called when the firmware update thread has run.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
hw_ostc_device_fwupdate was introduced after 0.4.2 so ifdef it to
libdivecomputer >= 0.5.0. The scope of users interested in this feature
probably isn't big enough to justify a bump of our dependencies to a
unreleased version of libdivecomputer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
When dropping to the bottom in plan (and add) mode, the gas label was
placed along the diagonal line from (0,0) to the second dive data point
(i.e. the one at the end of the "at deptch" segment). That looks terrible,
the label needs to be along the segment that we are spending at the
bottom.
This patch fixes that problem.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This helper function is used to get a nickname for a dive computer, when
the model information on its own may be ambiguous (ie there may be
multiple dive computers of the same model, and we've nicknamed them by
owner).
However, the helper did completely the wrong thing if it didn't find a
dive computer entry at all due to a missing device ID - it would just
return empty. Which is bogus: it should return the model name, the same
way it does if the nickname is missing.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
First out is firmware updates.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This adds a icon to the Vyper config page. The image is taken by me of
my Suunto Vyper. Thats the reason for the quality.
Question: Would it be ok to grab a PR image from Suunto's web page to
use here? If so they got better ones...
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
We currently don't support update firmware for the OSTC3. Where waiting
for support in libdivecomputer for that, so disable that button for now.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This code connects the final parts of the generic firmware update code.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Normally, all samples have depths associated with them, and most dive
computers likely don't even have the concept of a sample without a depth.
However, the new Suunto EON Steel definitely has samples with just time
updates (and perhaps other data, like events) and no depth at all. We
get unhappy about that, and interpret it as having a zero depth. Which
doesn't look very nice.
This just makes all samples default to the same depth as the previous
sample. For normal samples with a depth value, that will just override
that default.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
-make the dive profile dynamic to check user selected units from the
settings file.
-some of the code needs to be refactored and copied to a more
appropriate location.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Edit the HTML exporter to export data fields with user selected units.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|