2017-06-15Fix buffer overrun and primary sensor id issues in Liquivision importGravatar Robert Bodily
This changeset fixes 5 issues specific to importing from Liquivision dive logs: Issue #1: Buffer overrun causes segmentation fault. At the end of a dive record, untranslatable data is skipped and the file is scanned for the start of the next dive. This scan was implemented without regard to buffer size and so the scan ran over the buffer boundary when trying to scan for the next record after importing the last record in the file. Issue #2: Incorrect identification of the primary sensor. The primary tank pressure transmitter was being identified by using the sensor ID reported in the first pressure event record encountered. When diving with multiple transmitters (buddy, student, or group transmitters), this is often not the case and results in the buddy or other group transmitter's pressure data being imported instead of the primary's. Through empirical observation of several multi-sensor logs, I identified a previously unhandled event code (0x10) as marking a sensor identification event record. Parsing this record allows the primary and other sensors to be definitively identified regardless of which one sends the first pressure event. Issue #3: Sensor values added to the sample collection regardless of sensor ID. When processing events, the code previously dropped through to create a sample for every pressure event record, regardless of which sensor ID that event is associated with. Pressure events for sensors other than the primary are now ignored and omitted from the sample collection. Issue #4: Duplicate samples when pressure event time syncs with sample time. The sample index (d) was not incremented in this specific case resulting in a duplicate sample (for the same sample time) being created when processing the next pressure event record. Issue #5: Unsigned time difference results in erroneous interpolated samples. When interpolating/extrapolating depth and temperature values for a between- samples pressure event, a signed time value is subtracted from an unsigned time value, resulting in an unsigned term. This term is used as a scaling factor and should be signed to allow for a negative value. Currently, negative values are instead treated as large unsigned values which result in erroneous scaled depth and temperature values. Signed-off-by: Robert Bodily <robert@bodily.com> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-04-29Add SPDX header to core C filesGravatar Dirk Hohndel
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-03-11Merge branch 'master' of https://github.com/dje29/subsurfaceGravatar Dirk Hohndel
2017-03-11We use 'setpoint' in UI. Use it also for documentation and comments. No ↵Gravatar Martin Měřinský
semantic change.
2017-03-09Fix potential double/float to int rounding errorsGravatar Jeremie Guichard
Not using lrint(f) when converting double/float to int creates rounding errors. This error was detected by TestParse::testParseDM4 failure on Windows. It was creating rounding inconsistencies on Linux too, see change in TestDiveDM4.xml. Enable -Wfloat-conversion for gcc version greater than 4.9.0 Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
2016-04-04Move subsurface-core to core and qt-mobile to mobile-widgetsGravatar Dirk Hohndel
Having subsurface-core as a directory name really messes with autocomplete and is obviously redundant. Simmilarly, qt-mobile caused an autocomplete conflict and also was inconsistent with the desktop-widget name for the directory containing the "other" UI. And while cleaning up the resulting change in the path name for include files, I decided to clean up those even more to make them consistent overall. This could have been handled in more commits, but since this requires a make clean before the build, it seemed more sensible to do it all in one. Signed-off-by: Dirk Hohndel <dirk@hohndel.org>