Age | Commit message (Collapse) | Author |
|
No reason to mess around with a 5 byte buffer when we have a
proper buffer available to receive a possibly 8 byte output
based on the format string. And silences compiler warning.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
|
|
This is a very timid start at making us actually use multiple sensors
without the magical special case for just CCR oxygen tracking.
It mainly does:
- turn the "sample->sensor" index into an array of two indexes, to
match the pressures themselves.
- get rid of dive->{oxygen_cylinder_index,diluent_cylinder_index},
since a CCR dive should now simply set the sample->sensor[] indices
correctly instead.
- in a couple of places, start actually looping over the sensors rather
than special-case the O2 case (although often the small "loops" are
just unrolled, since it's just two cases.
but in many cases we still end up only covering the zero sensor case,
because the CCR O2 sensor code coverage was fairly limited.
It's entirely possible (even likely) that this migth break some existing
case: it tries to be a fairly direct ("stupid") translation of the old
code, but unlike the preparatory patch this does actually does change
some semantics.
For example, right now the git loader code assumes that if the git save
data contains a o2pressure entry, it just hardcodes the O2 sensor index
to 1.
In fact, one issue is going to simply be that our file formats do not
have that multiple sensor format, but instead had very clearly encoded
things as being the CCR O2 pressure sensor.
But this is hopefully close to usable, and I will need feedback (and
maybe test cases) from people who have existing CCR dives with pressure
data.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
We currently carry two pressures around for all the samples and plot
info, but the second pressure is reserved for CCR dives as the O2
cylinder pressure.
That's kind of annoying when we *could* use it for regular sidemount
dives as the secondary pressure.
So start prepping for that instead: don't make it "pressure" and
"o2pressure", make it just be an array of two pressure values.
NOTE! This is purely mindless prepwork. It literally just does a
search-and-replace, keeping the exact same semantics, so "pressure[1]"
is still just O2 pressure.
But at some future date, we can now start using it for a second sensor
value for sidemount instead.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Not using lrint(f) when converting double/float to int
creates rounding errors.
This error was detected by TestParse::testParseDM4 failure
on Windows. It was creating rounding inconsistencies
on Linux too, see change in TestDiveDM4.xml.
Enable -Wfloat-conversion for gcc version greater than 4.9.0
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
|
|
Using gcc option "-Wfloat-conversion" is useful to catch
potential conversion errors (where lrint should be used).
rint returns double and still raises the same warning,
this is why this change updates all rint calls to lrint.
In few places, where input type is a float, corresponding
lrinf is used.
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
|
|
Having subsurface-core as a directory name really messes with
autocomplete and is obviously redundant. Simmilarly, qt-mobile caused an
autocomplete conflict and also was inconsistent with the desktop-widget
name for the directory containing the "other" UI.
And while cleaning up the resulting change in the path name for include
files, I decided to clean up those even more to make them consistent
overall.
This could have been handled in more commits, but since this requires a
make clean before the build, it seemed more sensible to do it all in one.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|