Age | Commit message (Collapse) | Author |
|
A few basic rules for gas validation:
We can't have <0%, or >100% of either O2 or He
O2 + He must not be >100%
Switch depth can't be <0%
This places limits on user-input values
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This allows calculation and selection of best mix in the planner cylinder
entry, by entering the gas depth, followed by "b" for best (trimix) mix, or
"bn" for best nitrox mix.
The UI is not intuitive, but it is quick and easy. At the very least, it
should be documented.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
If the value for "use" is negative or larger than the number of
elements in "enum cylinderuse", later CylindersModel::data() can
request a string in the lines of cylinderuse_text[cyl->cylinder_use],
which can SIGSEGV.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Having subsurface-core as a directory name really messes with
autocomplete and is obviously redundant. Simmilarly, qt-mobile caused an
autocomplete conflict and also was inconsistent with the desktop-widget
name for the directory containing the "other" UI.
And while cleaning up the resulting change in the path name for include
files, I decided to clean up those even more to make them consistent
overall.
This could have been handled in more commits, but since this requires a
make clean before the build, it seemed more sensible to do it all in one.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
This is questionable, but perhaps useful.
When showing imperial cylinder sizes, show both the nominal value (with
no compensation for compressibility of the gas) and the "actual" amount
of gas the cylinder contains.
So an AL80 will show as a size of "80 (77)cuft", because while 80 is the
nominal size, the actual amount of gas that will fit is just 77 cuft.
[Dirk Hohndel: adjusted to take translation of the unit into account]
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
We had two totally different usage cases for "get_volume_string()": one
that did the obvious "show this volume as a string", and one that tried
to show a cylinder size.
The function used a magic third argument (the working pressure of the
cylinder) to distinguish between the two cases, but it still got it
wrong.
A metric cylinder doesn't necessarily have a working pressure at all,
and the size is a wet size in liters. We'd pass in zero as the working
pressure, and if the volume units were set to cubic feet, the logic in
"get_volume_string()" would happily convert the metric wet size into the
wet size in cubic feet.
But that's completely wrong. An imperial cylinder size simply isn't a
wet size. If you don't have a working pressure, you cannot convert the
cylinder size to cubic feet. End of story.
So instead of having "get_volume_string()" have magical behavior
depending on working pressure, and getting it wrong anyway, just make
get_volume_string do a pure volume conversion, and create a whole new
function for showing the size of a cylinder.
Now, if the cylinder doesn't have a working pressure, we just show the
metric size, even if the user had asked for cubic feet.
[Dirk Hohndel: added call to translation functions for the units]
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Adding { } to if clause to avoid dangling warning
/Users/guidolerch/src/subsurface/qt-models/cylindermodel.cpp:117:
warning: add explicit braces to avoid dangling else [-Wdangling-else]
[Dirk Hohndel: combined two of Guido's patches to one that is simpler]
Signed-off-by: Guido Lerch <guido.lerch@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
When there is only one gasmix in the list we should show the icon that tells the
user that they can't remove the last gasmix from the list.
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
For the proper calculation, we need to take salinity and surface pressure
into account (rather than depth = bar * 10 - 10)
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
If we remove a cylidner for a unique gas and that is allowable, then don't
try to copy from cylinder with index same_gas (which is still -1).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Another change to make it easier to program the mobile ui. This was a
fairly easy patch: just moved the contents of the file and fixed the
includes.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Still trying to make it easier for the Mobile Port:
This patch is a bit bigger than I hopped, but it was the smallest that I
could get.
A lot of TODO items where added where I broke the code because the current
implementation would break the QML implementtion on the designer. I'll
most probably fix those myself when I finish the transition to the models
to the new folder.
I only moved both models at once because there's an interdependency
between them (seems inevitable, tough, but I'll take a better look at it
later).
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|