Age | Commit message (Collapse) | Author |
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
|
|
Let's show the units in CSV header so the actual fields have only the
values. This should be easier to parse with some other programs.
Fixes #472
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Let's show the units in CSV header so the actual fields have only the
values. This should be easier to parse with some other programs.
Fixes #472
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
This fixes issues #418 and $419.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Apparently recording cylinder pressure in PSI is not the only oddity
with Shearwater Desktop. It also records half the value, so doubling the
reading here.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Precision for the rounding is more than makes sense, but this satisfied
the test case.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
When doing the xslt transformation for UDDF export, the C source does
actually give a parameter units with value 0. Thus we need to treat
that case as normal mode.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
The current code that calls the export transformation supports parameter
units, so using it here to enable test mode.
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Fixes #376
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Fixes #377
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Make sure the Gas setup contains O2 value when trying to import that.
In latest log sample the Gas seems to contain the decompression
algorithm used. And as this value was grabbed after O2, we ended up with
empty O2.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
DivingLog seems to report cylinder start and end pressures in metric
format, but sample readings are in imperial in case user has selected
this unit. So we must convert the sample pressures in this case.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Math only takes numbers, need to ignore the ft part.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
If the last two fields were empty, we returned the field separator as
next to last value. Now we make sure not to return field separator as
field value.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
We really need the decimal separator to get correct results
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
We need to define the import variables that we use. This should fix the
Seabear HUDC import and thus the corresponding test case.
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
We need to set the attributes before we can start parsing other tags,
as cylinder.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
This should allow us to add different attributes to the samples while
parsing the log.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|
|
This imports the events from AV1 using the original event description.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
|