From b79ef63388dea9954037dbc5c9406c8de649ec32 Mon Sep 17 00:00:00 2001 From: Miika Turkia Date: Thu, 9 Jan 2014 23:14:49 +0200 Subject: Do not plot temperatures on DM4 import if no info If we do not have temperature readings, we do not want to plot the temperature samples either. See #415 Signed-off-by: Miika Turkia Signed-off-by: Dirk Hohndel --- parse-xml.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/parse-xml.c b/parse-xml.c index 8fc504a3f..db26190b9 100644 --- a/parse-xml.c +++ b/parse-xml.c @@ -1802,7 +1802,7 @@ extern int dm4_dive(void *param, int columns, char **data, char **column) else cur_sample->depth.mm = cur_dive->dc.maxdepth.mm; - if (tempBlob) + if (data[18] && data[18][0]) cur_sample->temperature.mkelvin = C_to_mkelvin(tempBlob[i]); if (data[19] && data[19][0]) cur_sample->cylinderpressure.mbar = pressureBlob[i] ; -- cgit v1.2.3-70-g09d2