From f2a6a76b3e64858691dda623873b2d40c1e98add Mon Sep 17 00:00:00 2001 From: Linus Torvalds Date: Fri, 21 Jul 2017 13:37:34 -0700 Subject: Fix up o2 pressure sensor handling at load time Because of how we traditionally did things, the "o2pressure" parsing depends on implicitly setting the sensor index to the last cylinder that was marked as being used for oxygen. We also always defaulted the primary sensor (which is used for the diluent tank for CCR) to cylinder 0, but that doesn't work when the oxygen tank is cylinder 0. This gets that right at file loading time, and unifies the xml and git sample parsing to make them match. The new defaults are: - unless anything else is explicitly specified, the primary sensor is associated with the first tank, and the secondary sensor is associated with the second tank - if we're a CCR dive, and have an explicit oxygen tank, we associate the secondary sensor with that oxygen cylinder. The primary sensor will be switched over to the second cylinder if the oxygen cylinder is the first one. This may sound backwards, but matches our traditional behavior where the O2 pressure was the secondary pressure. This is definitely not pretty, but it gets our historical files working right, and is at least reasonably sensible. Signed-off-by: Linus Torvalds Signed-off-by: Dirk Hohndel --- core/load-git.c | 22 ++++++++++++++++------ core/parse-xml.c | 57 ++++++++++++++++++++++++++++++++++---------------------- core/save-git.c | 16 ++++++++++++++-- core/save-xml.c | 16 ++++++++++++++-- 4 files changed, 79 insertions(+), 32 deletions(-) (limited to 'core') diff --git a/core/load-git.c b/core/load-git.c index 87f6ecb25..6a3cc75ce 100644 --- a/core/load-git.c +++ b/core/load-git.c @@ -354,6 +354,7 @@ static char *parse_keyvalue_entry(void (*fn)(void *, const char *, const char *) } static int cylinder_index, weightsystem_index; +static int o2pressure_sensor; static void parse_cylinder_keyvalue(void *_cylinder, const char *key, const char *value) { @@ -397,7 +398,6 @@ static void parse_dive_cylinder(char *line, struct membuffer *str, void *_dive) struct dive *dive = _dive; cylinder_t *cylinder = dive->cylinder + cylinder_index; - cylinder_index++; cylinder->type.description = get_utf8(str); for (;;) { char c; @@ -407,6 +407,9 @@ static void parse_dive_cylinder(char *line, struct membuffer *str, void *_dive) break; line = parse_keyvalue_entry(parse_cylinder_keyvalue, cylinder, line); } + if (cylinder->cylinder_use == OXYGEN) + o2pressure_sensor = cylinder_index; + cylinder_index++; } static void parse_weightsystem_keyvalue(void *_ws, const char *key, const char *value) @@ -540,11 +543,6 @@ static void parse_sample_keyvalue(void *_sample, const char *key, const char *va } if (!strcmp(key, "o2pressure")) { pressure_t p = get_pressure(value); - // - // FIXME!!! What's the O2 cylinder index? - // get_cylinder_idx_by_use(dive, OXYGEN) - // - sample->sensor[1] = 1; sample->pressure[1].mbar = p.mbar; return; } @@ -599,6 +597,13 @@ static char *parse_sample_unit(struct sample *sample, double val, char *unit) * missing sample pressure doesn't mean "same as last * time", but "interpolate". We clear those ones * explicitly. + * + * NOTE! We default sensor use to 0, 1 respetively for + * the two sensors, but for CCR dives with explicit + * OXYGEN bottles we set the secondary sensor to that. + * Then the primary sensor will be either the first + * or the second cylinder depending on what isn't an + * oxygen cylinder. */ static struct sample *new_sample(struct divecomputer *dc) { @@ -606,6 +611,10 @@ static struct sample *new_sample(struct divecomputer *dc) if (sample != dc->sample) { memcpy(sample, sample-1, sizeof(struct sample)); sample->pressure[0].mbar = 0; + sample->pressure[1].mbar = 0; + } else { + sample->sensor[0] = !o2pressure_sensor; + sample->sensor[1] = o2pressure_sensor; } return sample; } @@ -1502,6 +1511,7 @@ static int parse_dive_entry(git_repository *repo, const git_tree_entry *entry, c if (*suffix) dive->number = atoi(suffix+1); cylinder_index = weightsystem_index = 0; + o2pressure_sensor = 1; for_each_line(blob, dive_parser, active_dive); git_blob_free(blob); return 0; diff --git a/core/parse-xml.c b/core/parse-xml.c index fdb2dab44..c56a96ddb 100644 --- a/core/parse-xml.c +++ b/core/parse-xml.c @@ -150,8 +150,8 @@ static bool in_settings = false; static bool in_userid = false; static struct tm cur_tm; static int cur_cylinder_index, cur_ws_index; -static int lastndl, laststoptime, laststopdepth, lastcns, lastpo2, lastindeco; -static int lastcylinderindex, lastsensor, lasto2sensor = 1, next_o2_sensor; +static int lastcylinderindex, next_o2_sensor; +static int o2pressure_sensor; static struct extra_data cur_extra_data; /* @@ -356,7 +356,7 @@ static void cylinder_use(char *buffer, enum cylinderuse *cyl_use) int use = cylinderuse_from_text(buffer); *cyl_use = use; if (use == OXYGEN) - lasto2sensor = cur_cylinder_index; + o2pressure_sensor = cur_cylinder_index; } } @@ -794,7 +794,6 @@ static void get_cylinderindex(char *buffer, uint8_t *i) static void get_sensor(char *buffer, uint8_t *i) { *i = atoi(buffer); - lastsensor = *i; } static void parse_libdc_deco(char *buffer, struct sample *s) @@ -1526,9 +1525,7 @@ static void reset_dc_info(struct divecomputer *dc) { /* WARN: reset dc info does't touch the dc? */ (void) dc; - lastcns = lastpo2 = lastndl = laststoptime = laststopdepth = lastindeco = 0; - lastsensor = lastcylinderindex = 0; - lasto2sensor = 1; + lastcylinderindex = 0; } static void reset_dc_settings(void) @@ -1606,6 +1603,7 @@ static void dive_start(void) add_dive_to_trip(cur_dive, cur_trip); cur_dive->tripflag = IN_TRIP; } + o2pressure_sensor = 1; } static void dive_end(void) @@ -1714,17 +1712,38 @@ static void ws_end(void) cur_ws_index++; } +/* + * By default the sample data does not change unless the + * save-file gives an explicit new value. So we copy the + * data from the previous sample if one exists, and then + * the parsing will update it as necessary. + * + * There are a few exceptions, like the sample pressure: + * missing sample pressure doesn't mean "same as last + * time", but "interpolate". We clear those ones + * explicitly. + * + * NOTE! We default sensor use to 0, 1 respetively for + * the two sensors, but for CCR dives with explicit + * OXYGEN bottles we set the secondary sensor to that. + * Then the primary sensor will be either the first + * or the second cylinder depending on what isn't an + * oxygen cylinder. + */ static void sample_start(void) { - cur_sample = prepare_sample(get_dc()); - cur_sample->ndl.seconds = lastndl; - cur_sample->in_deco = lastindeco; - cur_sample->stoptime.seconds = laststoptime; - cur_sample->stopdepth.mm = laststopdepth; - cur_sample->cns = lastcns; - cur_sample->setpoint.mbar = lastpo2; - cur_sample->sensor[0] = lastsensor; - cur_sample->sensor[1] = lasto2sensor; + struct divecomputer *dc = get_dc(); + struct sample *sample = prepare_sample(dc); + + if (sample != dc->sample) { + memcpy(sample, sample-1, sizeof(struct sample)); + sample->pressure[0].mbar = 0; + sample->pressure[1].mbar = 0; + } else { + sample->sensor[0] = !o2pressure_sensor; + sample->sensor[1] = o2pressure_sensor; + } + cur_sample = sample; next_o2_sensor = 0; } @@ -1734,12 +1753,6 @@ static void sample_end(void) return; finish_sample(get_dc()); - lastndl = cur_sample->ndl.seconds; - lastindeco = cur_sample->in_deco; - laststoptime = cur_sample->stoptime.seconds; - laststopdepth = cur_sample->stopdepth.mm; - lastcns = cur_sample->cns; - lastpo2 = cur_sample->setpoint.mbar; cur_sample = NULL; } diff --git a/core/save-git.c b/core/save-git.c index 2647b88ae..b734f59f4 100644 --- a/core/save-git.c +++ b/core/save-git.c @@ -321,10 +321,22 @@ static void save_sample(struct membuffer *b, struct sample *sample, struct sampl put_format(b, "\n"); } -static void save_samples(struct membuffer *b, int nr, struct sample *s) +static void save_samples(struct membuffer *b, struct dive *dive, struct divecomputer *dc) { + int nr; + int o2sensor; + struct sample *s; struct sample dummy = {}; + /* Set up default pressure sensor indexes */ + o2sensor = get_cylinder_idx_by_use(dive, OXYGEN); + if (o2sensor < 0) + o2sensor = 1; + dummy.sensor[0] = !o2sensor; + dummy.sensor[1] = o2sensor; + + s = dc->sample; + nr = dc->samples; while (--nr >= 0) { save_sample(b, s, &dummy); s++; @@ -379,7 +391,7 @@ static void save_dc(struct membuffer *b, struct dive *dive, struct divecomputer save_extra_data(b, dc->extra_data); save_events(b, dive, dc->events); - save_samples(b, dc->samples, dc->sample); + save_samples(b, dive, dc); } /* diff --git a/core/save-xml.c b/core/save-xml.c index 151ebf0a3..73a00f54a 100644 --- a/core/save-xml.c +++ b/core/save-xml.c @@ -331,10 +331,22 @@ static void show_date(struct membuffer *b, timestamp_t when) tm.tm_hour, tm.tm_min, tm.tm_sec); } -static void save_samples(struct membuffer *b, int nr, struct sample *s) +static void save_samples(struct membuffer *b, struct dive *dive, struct divecomputer *dc) { + int nr; + int o2sensor; + struct sample *s; struct sample dummy = {}; + /* Set up default pressure sensor indexes */ + o2sensor = get_cylinder_idx_by_use(dive, OXYGEN); + if (o2sensor < 0) + o2sensor = 1; + dummy.sensor[0] = !o2sensor; + dummy.sensor[1] = o2sensor; + + s = dc->sample; + nr = dc->samples; while (--nr >= 0) { save_sample(b, s, &dummy); s++; @@ -368,7 +380,7 @@ static void save_dc(struct membuffer *b, struct dive *dive, struct divecomputer put_duration(b, dc->surfacetime, " ", " min\n"); save_extra_data(b, dc->extra_data); save_events(b, dive, dc->events); - save_samples(b, dc->samples, dc->sample); + save_samples(b, dive, dc); put_format(b, " \n"); } -- cgit v1.2.3-70-g09d2