From 601ac0c3624b1cdb3c1bb44b213d72eba400e642 Mon Sep 17 00:00:00 2001 From: Dirk Hohndel Date: Sun, 28 Oct 2012 13:17:12 -0700 Subject: Display air temperature in the info notebook page So far we don't parse air temperature data via libdivecomputer. Nor are we set up to allow the user to manually enter it. We can parse it when downloading from a Uemis Zurich, though. This feature was suggested via trac.hohndel.org; this commit implements only part of what is requested there, so I simply reference the ticket here without closing it. References ticket #7 Signed-off-by: Dirk Hohndel --- uemis.c | 2 ++ 1 file changed, 2 insertions(+) (limited to 'uemis.c') diff --git a/uemis.c b/uemis.c index 237fd6c16..25ff9bf49 100644 --- a/uemis.c +++ b/uemis.c @@ -192,6 +192,8 @@ void uemis_parse_divelog_binary(char *base64, void *datap) { datalen = uemis_convert_base64(base64, &data); + dive->airtemp.mkelvin = *(uint16_t *)(data + 45) * 100 + 273150; + /* dive template in use: 0 = air 1 = nitrox (B) -- cgit v1.2.3-70-g09d2