Use PSCR gas when computing O2 toxicity
Both the calculations for CNS and OTU did not take into account the pO2 drop when using a PSCR. Furthermore, there was some unit confusion due to not using internal units. Reported-by: arosl Signed-off-by: Robert C. Helling <helling@atdotde.de>
Diffstat (limited to 'core/gas.h')
-rw-r--r--core/gas.h2
1 files changed, 2 insertions, 0 deletions
diff --git a/core/gas.h b/core/gas.h
index cd7c9e389..83eef72e9 100644
--- a/core/gas.h
+++ b/core/gas.h
@@ -59,6 +59,8 @@ static inline int get_n2(struct gasmix mix)
return 1000 - get_o2(mix) - get_he(mix);
}
+int pscr_o2(const double amb_pressure, struct gasmix mix);
+
struct gas_pressures {
double o2, n2, he;
};