aboutsummaryrefslogtreecommitdiffstats
path: root/core
diff options
context:
space:
mode:
authorGravatar Linus Torvalds <torvalds@linux-foundation.org>2016-04-02 07:28:03 -0500
committerGravatar Dirk Hohndel <dirk@hohndel.org>2016-04-04 22:37:18 -0700
commiteb5907ab3b8805d4c9990cba45ac4b46f6e5cdb8 (patch)
tree479922f6bf0b1a34a94ce28be844e9a64cc67152 /core
parent7be962bfc2879a72c32ff67518731347dcdff6de (diff)
downloadsubsurface-eb5907ab3b8805d4c9990cba45ac4b46f6e5cdb8.tar.gz
Remove linear pressure interpolation detection code
Dirk says that divinglog hasn't been doing the linear pressure interpolation for a long while, so we're doing extra dive fixups that really aren't needed any more. Also, the code is actually buggy: it only ever worked on the first cylinder anyway (because only the first cylinder pressure_delta[] would be initialized). That was probably perfectly fine in practice, since it's unlikely that many tech divers used old versions of divinglog anyway, so the bug per se isn't a reason to remove it - but it is a sign that the code was a bit hard to read, so let's get rid of it if there is no reason to maintain it or fix it. Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Diffstat (limited to 'core')
-rw-r--r--core/dive.c52
1 files changed, 2 insertions, 50 deletions
diff --git a/core/dive.c b/core/dive.c
index ce730da28..64cf48a58 100644
--- a/core/dive.c
+++ b/core/dive.c
@@ -1306,17 +1306,12 @@ static void fixup_dc_cylinder_index(struct dive *dive, struct divecomputer *dc)
}
}
-/*
- * Simplify dc pressure information:
- * (a) Remove redundant pressure information
- * (b) Remove linearly interpolated pressure data
- */
+/* Remove redundant pressure information */
static void simplify_dc_pressures(struct dive *dive, struct divecomputer *dc)
{
- int i, j;
+ int i;
int lastindex = -1;
int lastpressure = 0, lasto2pressure = 0;
- int pressure_delta[MAX_CYLINDERS] = { INT_MAX, };
for (i = 0; i < dc->samples; i++) {
struct sample *sample = dc->sample + i;
@@ -1325,60 +1320,17 @@ static void simplify_dc_pressures(struct dive *dive, struct divecomputer *dc)
int index;
index = sample->sensor;
-
if (index == lastindex) {
/* Remove duplicate redundant pressure information */
if (pressure == lastpressure)
sample->cylinderpressure.mbar = 0;
if (o2_pressure == lasto2pressure)
sample->o2cylinderpressure.mbar = 0;
- /* check for simply linear data in the samples
- +INT_MAX means uninitialized, -INT_MAX means not linear */
- if (pressure_delta[index] != -INT_MAX && lastpressure) {
- if (pressure_delta[index] == INT_MAX) {
- pressure_delta[index] = abs(pressure - lastpressure);
- } else {
- int cur_delta = abs(pressure - lastpressure);
- if (cur_delta && abs(cur_delta - pressure_delta[index]) > 150) {
- /* ok the samples aren't just a linearisation
- * between start and end */
- pressure_delta[index] = -INT_MAX;
- }
- }
- }
}
lastindex = index;
lastpressure = pressure;
lasto2pressure = o2_pressure;
}
-
- /* if all the samples for a cylinder have pressure data that
- * is basically equidistant throw out the sample cylinder pressure
- * information but make sure we still have a valid start and end
- * pressure
- * this happens when DivingLog decides to linearalize the
- * pressure between beginning and end and for strange reasons
- * decides to put that in the sample data as if it came from
- * the dive computer; we don't want that (we'll visualize with
- * constant SAC rate instead)
- * WARNING WARNING - I have only seen this in single tank dives
- * --- maybe I should try to create a multi tank dive and see what
- * --- divinglog does there - but the code right now is only tested
- * --- for the single tank case */
- for (j = 0; j < MAX_CYLINDERS; j++) {
- if (abs(pressure_delta[j]) != INT_MAX) {
- cylinder_t *cyl = dive->cylinder + j;
- for (i = 0; i < dc->samples; i++)
- if (dc->sample[i].sensor == j)
- dc->sample[i].cylinderpressure.mbar = 0;
- if (!cyl->start.mbar)
- cyl->start.mbar = cyl->sample_start.mbar;
- if (!cyl->end.mbar)
- cyl->end.mbar = cyl->sample_end.mbar;
- cyl->sample_start.mbar = 0;
- cyl->sample_end.mbar = 0;
- }
- }
}
/* FIXME! sensor -> cylinder mapping? */