diff --git a/profile.c b/profile.c
index 93222f5f1..d64d1c7e7 100644
--- a/profile.c
+++ b/profile.c
@@ -558,12 +558,12 @@ struct plot_data *populate_plot_entries(struct dive *dive, struct divecomputer *
entry->in_deco = sample->in_deco;
entry->cns = sample->cns;
if (dc->dctype == CCR) {
- entry->o2setpoint = sample->o2setpoint.mbar / 1000.0; // for rebreathers
+ entry->o2setpoint = sample->setpoint.mbar / 1000.0; // for rebreathers
entry->o2sensor[0] = sample->o2sensor[0].mbar / 1000.0; // for up to three rebreather O2 sensors
entry->o2sensor[1] = sample->o2sensor[1].mbar / 1000.0;
entry->o2sensor[2] = sample->o2sensor[2].mbar / 1000.0;
} else {
- entry->pressures.o2 = sample->po2.mbar / 1000.0;
+ entry->pressures.o2 = sample->setpoint.mbar / 1000.0;
}
/* FIXME! sensor index -> cylinder index translation! */
entry->cylinderindex = sample->sensor;
@@ -913,7 +913,7 @@ void fill_o2_values(struct divecomputer *dc, struct plot_info *pi, struct dive *
/* For CCR:
* In the samples from each dive computer, any duplicate values for the
* oxygen sensors were removed (i.e. set to 0) in order to conserve
- * storage space (see function fuxup_dive_dc). But for drawing the prodile
+ * storage space (see function fixup_dive_dc). But for drawing the profile
* a complete series of valid o2 pressure values is required. This function
* takes the oxygen sensor data and setpoint values from the structures
* of plotinfo and re-inserts the duplicate values set to 0 so
@@ -1008,10 +1008,9 @@ void create_plot_info_new(struct dive *dive, struct divecomputer *dc, struct plo
check_gas_change_events(dive, dc, pi); /* Populate the gas index from the gas change events */
setup_gas_sensor_pressure(dive, dc, pi); /* Try to populate our gas pressure knowledge */
populate_pressure_information(dive, dc, pi, NONDILUENT); /* .. calculate missing pressure entries for all gasses except diluent */
- if (dc->dctype == CCR) { /* For CCR dives.. */
- printf("CCR DIVE: %s (%d O2 sensors)\n", dc->model, dc->no_o2sensors);
+ if (dc->dctype == CCR) /* For CCR dives.. */
populate_pressure_information(dive, dc, pi, DILUENT); /* .. calculate missing diluent gas pressure entries */
- }
+
fill_o2_values(dc, pi, dive); /* .. and insert the O2 sensor data having 0 values. */
calculate_sac(dive, pi); /* Calculate sac */
calculate_deco_information(dive, dc, pi, false); /* and ceiling information, using gradient factor values in Preferences) */