1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
|
// Subsurface 4.2 User Manual
// ==========================
// :author: Manual authors: Jacco van Koll, Dirk Hohndel, Reinout Hoornweg,
// Linus Torvalds, Miika Turkia, Amit Chaudhuri, Jan Schubert, Willem
// Ferguson, Salvador Cuñat, Pedro Neves
// :revnumber: 4.2
// :revdate: July 2014
:icons:
:toc:
:toc-placement: manual
:numbered:
// :website: http://subsurface-divelog.org
image::images/Subsurface4Banner.jpg["Banner",align="center"]
[big]#USER MANUAL#
*Manual authors*: Willem Ferguson, Jacco van Koll, Dirk Hohndel, Reinout Hoornweg,
Linus Torvalds, Miika Turkia, Amit Chaudhuri, Jan Schubert, Salvador Cuñat, Pedro Neves
[blue]#_Version 4.4, February 2015_#
Welcome as a user of _Subsurface_, an advanced dive logging program with
extensive infrastructure to describe, organise, interpret and print scuba
and free dives. _Subsurface_ offers many advantages over other similar
software solutions:
- Do you need a flexible way of logging dives using recreational equipment,
even not using a dive computer?
- Do you use two different dive computer brands, each with its own proprietary
software for downloading dive logs? Do you dive with rebreathers as well
as open circuit or recreational equipment? Do you use a Reefnet Sensus time-depth
recorder in conjunction with a dive computer? _Subsurface_ offers a standard
interface for downloading dive logs from all these different pieces of
equipment and to store and analyse the dive logs within a unified system.
- Do you use more than one operating system? _Subsurface_ is fully compatible
with Mac, Linux and Windows, allowing you to access your dive log on each
of your operating systems using a single application.
- Do you use Linux or Mac and your dive computer has only Windows-based software
for downloading dive information (e.g. Mares)? _Subsurface_ provides a way of
downloading and analysing your dive logs on other operating systems.
- Do you need an intuitive graphical dive planner that integrates with and takes
into account the dives that have already been logged?
_Subsurface_ binaries are available for Windows PCs (Win XP or later), Intel
based Macs (OS/X) and many Linux distributions. _Subsurface_ can be built for
many more hardware platforms and software environments where Qt and
libdivecomputer are available.
The scope of this document is the use of the _Subsurface_ program. To install
the software, consult the _Downloads_ page on the
http://subsurface-divelog.org/[_Subsurface_ web site].
Please discuss issues with this program by sending an email to
mailto:subsurface@subsurface-divelog.org[our mailing list] and report bugs at
http://trac.hohndel.org[our bugtracker]. For instructions on how to build the
software and (if needed) its dependencies please consult the INSTALL file
included with the source code.
*Audience*: Recreational Scuba Divers, Free Divers, Tec Divers, Professional
Divers
toc::[]
[[S_UserSurvey]]
Using this manual
-----------------
When opened from within _Subsurface_, this manual does not have external controls. However,
a _SEARCH_ function is important. This is activated by pressing control-F or command-F on
the keyboard. A text box appears at the bottom of the window. Use this to search for
any term in the manual.
The user survey
---------------
In order to develop _Subsurface_ in a way that serves its users in the best possible way,
it is important to have some user information. Upon launching _Subsurface_
after using this software for a week or so, a one-box user survey pops up. It is entirely
optional and the user controls what, if any, data are sent to the _Subsurface_ development
team. Any data that the user chooses to send is extremely useful, and will only be
used to steer future development and to customise the software to fit the needs of
the _Subsurface_ users. If one completes the survey, or clicks the option not to
be asked again, that should be the last communication of this nature one receives.
However, if one's diving and/or subsurface habits change and one wishes to provide
another survey, this can be done by launching _Subsurface_ with the _--survey_ option on the
command line.
[[S_StartUsing]]
Start Using the Program
-----------------------
The _Subsurface_ window is usually divided into four panels with a *Main
Menu* (File Import Log View Filter Help) at the top of the window (for Windows
and Linux) or the top of the screen (for Mac and Ubuntu Unity). The four panels are:
1. The *Dive List* to the bottom left containing a list of all the dives in the
user's
dive log. A dive can be selected and highlighted on the dive list by clicking on
it. In most situations the up/down keys can be used to switch
between dives. The *Dive List* is an important tool for manipulating a dive log.
2. The *Dive Map* to the bottom right, showing the user's dive sites on a world
map
and centred on the site of the last dive selected in the *Dive List*.
3. The *Dive Info* to the top left, giving more detailed information on the
dive selected in the *Dive List*, including some statistics for the selected dive or for all
highlighted dive(s).
4. The *Dive Profile* to the top right, showing a graphical dive profile of the
selected dive in the *Dive List*.
The dividers between panels can be dragged in order to change the size of any of
the panels. _Subsurface_ remembers the position of the dividers, so the next
time _Subsurface_ starts it uses the positions of the dividers from when the program
was last used.
If a dive is selected in the *Dive List*, the dive location, detailed information
and profile of
the _selected dive_ are shown in the respective panels. On the other hand, if
one highlights more than one dive the last highlighted dive is the _selected
dive_, but summary data of all _highlighted dives_ are shown in the *Stats* tab
of the *Dive Info* panel (maximum, minimum and average depths, durations, water
temperatures and SAC; total time and number of dives selected).
[[S_ViewPanels]]
image::images/main_window_f20.jpg["The Main Window",align="center"]
The user can determine which of the four panels are displayed by selecting the
*View* option on the main menu. This feature gives the user several choices of
display:
*All*: show all four of the panels as in the screenshot above.
*Divelist*: Show only the Dive List.
*Profile*: Show only the Dive Profile of the selected dive.
*Info*: Show only the Dive Notes about the last selected dive and statistics for
all highlighted dives.
*Globe*: Show only the world map, centred on the last selected dive.
Like many other functions that can be accessed via the Main Menu, these options
can be triggered using keyboard shortcuts. The shortcuts for a particular system
are shown with an underline in the main menu entries. Since different Operating
Systems and the user chosen language may cause _Subsurface_ to use different
shortcut keys they are not listed here in the user manual.
When the program is started for the first time, it shows no information at all.
This is because the program doesn't have any dive information available. In the
following sections, the procedures to create a new logbook will be described.
[[S_NewLogbook]]
Creating a new logbook
----------------------
Select _File -> New Logbook_ from the main menu. All existing dive data are
cleared so that new information can be added. If there are unsaved data in an
open logbook, the user is asked whether the open logbook should be
saved before a new logbook is created.
[[S_GetInformation]]
== Storing dive information in the logbook
Now that a new logbook was created, it is simple to add dive data to it.
_Subsurface_ allows several ways of adding dive data to a logbook, detailed
in the following sections.
1) If the user has a handwritten divelog, a spreadsheet or another form of
manually maintained divelog, dive data can be added to the logbook using
one of these approaches:
- Enter dive information by hand. This is useful if the diver did not
use a dive computer and dives were recorded in a written logbook. See:
xref:S_EnterData[Entering dive information by hand]
- Import dive log information that has been maintained either as a spreadsheet
or as a CSV file. Refer to: xref:S_Appendix_D[APPENDIX D: Exporting a spreadsheet to CSV format] and
to xref:S_ImportingCSVDives[Importing dives in CSV format].
2) If one has dives recorded using a dive computer, the depth profile of the
dive and a large amount of additional information can be accessed. These dives
can be imported from:
- The divecomputer itself. See: xref:S_ImportDiveComputer[Importing new dive information from a Dive Computer] or
- Proprietary software distributed by manufacturers of dive computers. Refer
to: xref:S_ImportingAlienDiveLogs[Importing dive information from other digital data sources or other data formats].
- Import from spreadsheet or CSV files containing dive profiles.
See: xref:S_ImportingCSVDives[Importing dives in CSV format from dive computers or other dive log software]
[[S_EnterData]]
=== Entering dive information by hand
This is usually the approach for dives without a dive computer. The basic record
of information within _Subsurface_ is a dive. The most important information
in a simple dive logbook usually includes dive type, date, time, duration,
depth, the names of your dive buddy and of the dive master or dive guide, and
some remarks about the dive. _Subsurface_ can store much more information
than this for each dive. In order to add a dive to a dive log, select _Log
-> Add Dive_ from the Main Menu. The program then shows three panels to enter
information for a dive: two tabs in the *Dive Info* panel (*Dive Notes* and
*Equipment*), as well as the *Dive Profile* panel that displays a graphical profile
of each dive. These panels are respectively marked [red]#A#, [red]#B# and
[red]#C#
in the figure below. Each of these tabs will now be explained for data entry.
image::images/AddDive1_f20.jpg["FIGURE: Add dive",align="center"]
When one edits a field in Dive notes or Equipment panels, _Subsurface_ enters *Editing Mode*,
indicated by the message in the blue box at the top of the _Dive Notes_ panel (see the image below). This message is
displayed in all the panels under Dive notes and Equipment when in *Editing Mode*.
image::images/BlueEditBar_f20.jpg["Blue edit bar",align="center"]
The _Save_ button should only be selected after all the parts of a dive have been entered.
When entering dives by hand, the _Info_, _Equipment_ and _Profile_ tabs should be completed
before saving the information. By selecting the _Save_ button, a local copy of the information
for this specific dive is saved in memory. When one closes Subsurface, the program will
ask again, this time whether the complete dive log should be saved on disk or not.
==== Dive Notes
This panel contains the date, time and place information for a particular dive,
environmental conditions, co-divers and buddies, as well as some descriptive
information. If one clicks on the *Dive Notes* tab, the following
fields are visible:
image::images/AddDive2_f20.jpg["FIGURE: The Dive Notes tab",align="center"]
The *Time* field reflects the date and the time of the dive. By clicking
the date, a calendar is displayed from which
one can choose the correct date. Press ESC to escape from the calendar.
The time values (hour and minutes) can also be
edited directly by clicking on each of them in the text box and by overtyping the
information displayed. The default date is the present date and the default time is
an hour in advance of the present time.
*Air and water temperatures*: the air and water temperatures during the
dive can be typed directly on the fields to the right of the Start time.
Temperature units are not needed, as they will be automatically supplied by
_Subsurface_. Only the numerical value must be
typed by the user (the units selected in the 'Preferences'
will determine whether metric or imperial units are used).
*Location*: Here the name of the dive site can be entered, e.g. "Tihany, Lake
Balaton,
Hungary". Auto completion of location names will make this easier if one
frequently dives at the same sites.
*Coordinates*: The geographic coordinates of the dive site should be entered
here. These can come from three sources:
a. One can find the coordinates on the world map in the bottom right hand
part
of the Subsurface window. The map displays a green bar indicating "No location
data - Move the map and double-click to set the dive location". Upon a double-click
at the appropriate place, the green bar disappears and the coordinates are
stored.
b. The coordinates can be obtained from the _Subsurface_ Companion app if the
user has an Android or iPhone device with GPS and if the coordinates of the dive site
were stored using that device.
xref:S_Companion[Click here for more information]
c. The coordinates can be entered by hand if they are known, using one of
four formats with latitude followed by longitude:
ISO 6709 Annex D format e.g. 30°13'28.9"N 30°49'1.5"E
Degrees and decimal minutes, e.g. N30° 13.49760' , E30° 49.30788'
Degrees minutes seconds, e.g. N30° 13' 29.8" , E30° 49' 1.5"
Decimal degrees, e.g. 30.22496 , 30.821798
Southern hemisphere latitudes are given with a *S*, e.g. S30°, or with a
negative value, e.g. -30.22496. Similarly western longitudes are given with a
*W*, e.g. W07°, or with a negative value, e.g. -7.34323.
Please note that GPS coordinates of a dive site are linked to the Location
name - so adding coordinates to dives that do not have a location description
will cause unexpected behaviour (Subsurface will think that all of these
dives have the same location and try to keep their GPS coordinates the
same).
*Dive mode*: This is a dropdown box allowing one to choose the type of dive
performed. The options are OC (Open Circuit, the default setting, meant for most recreational dives),
Freedive (dive without SCUBA equipment), CCR (Closed-circuit
rebreather) and pSCR (Passive semi-closed rebreather).
*Divemaster*: The name of the dive master or dive guide for this dive can be
entered here.
Again, this field offers auto completion based on the list of dive masters in
the current logbook.
*Buddy*: In this field one can enter the name(s) of the buddy / buddies
(separated by commas) who accompanied the user on the dive. Auto completion
is offered based on the list of buddies in the current logbook.
*Suit*: The type of diving suit used for the dive can be entered here.
As with the other items, auto completion of the suit description is available.
Some dry-suit users may choose to use this field to record what combination of
suit and thermal protection undersuit was used.
*Rating*: One can provide a subjective overall rating of the dive on a
5-point scale by clicking the appropriate star on the rating scale.
*Visibility*: Similarly, one can provide a rating of visibility during the
dive on a
5-point scale by clicking the appropriate star.
*Tags*: Tags that describe the type of dive performed may
be entered here (separated by commas). Examples of common tags are boat, drift,
training, cave etc. _Subsurface_ has many built-in tags. Auto completion is once again offered.
For instance, if +cav+ was typed, then the tags *cave* and *cavern* are
shown for the user to choose from.
*Notes*: Any additional information can be typed here.
The *Save* and *Cancel* buttons are used to save all the information for tabs in
the info panel and in the dive profile panel, so there's no need to use them
until ALL other information has been added. Here is an example of a completed
Dive Notes panel:
image::images/CompletedDiveInfo_f20.jpg["FIGURE: A completed Dive Notes tab",align="center"]
==== Equipment
The Equipment tab allows the user to enter information about the type of
cylinder and gas used, as well as the weights used for a dive. This is a highly interactive part of
_Subsurface_ and the information on
cylinders and gases (entered here) affects the behaviour of the dive profile
(top right-hand panel).
[[S_CylinderData]]
*Cylinders*: The cylinder information is entered through a dialogue that looks
like this:
image::images/Gas_dialogue1_f20.jpg["FIGURE:Initial cylinder dialogue",align="center"]
The + button at the top right allows the user to add more cylinders for this
dive.
The dark dustbin icon on the left allows one to delete information for a
particular cylinder. Note that it is not possible to delete a cylinder if it is used during the
dive. One cylinder is implicitly used in the dive, even without a gas change event. Thus the first
cylinder cannot be deleted until another cylinder is created.
Start by selecting a cylinder type on the left-hand side of the
table. To select a cylinder, click in the *Type* box.
This brings up a button that can be used to display a dropdown list of
cylinders:
image::images/Gas_dialogue2_f20.jpg["FIGURE:The cylinder drop-down list button",align="center"]
The drop-down list can be used to select the cylinder type used
for the dive or the user may start typing in the box which shows the
available options for the entered characters. The
*Size* of the cylinder as well as its working pressure (*WorkPress*) will
automatically be shown in the dialogue. If a cylinder is not shown in the dropdown list,
type the name and description of that cylinder into the *Type* field.
Next, indicate the starting pressure and the ending pressure of
the
gas used during the dive. The unit of pressure (metric/imperial) corresponds
to the setting in the _Preferences_.
Finally, type in the gas mixture used in the *O2%* field. If air
was used, a value of 21% can be entered on this field, or it might be
left blank. If nitrox or trimix were used, their percentages of oxygen and/or
helium must be specified.
Any inappropriate fields should be left empty. After typing the information for
the cylinder, press _ENTER_ on the keyboard or click
outside the cell that contains the cursor. Information for any additional
cylinders can be added by using the + button at the top right hand. Following
is an example of a complete description for a
dive made using two cylinders (air and EAN50):
image::images/CylinderDataEntry3_f20.jpg["FIGURE: a completed cylinder dive information table",align="center"]
*Weights*: Information about the weight system used during a dive can be entered
using a dialogue very similar to that for the cylinder information. If the user
clicks the + button on the top right of the weights dialogue, the table looks
like this:
image::images/WeightsDataEntry1_f20.jpg["FIGURE: The Weights dialogue",align="center"]
If one then clicks on the *Type* field, a drop-down list becomes accessible
through a down-arrow:
image::images/WeightsDataEntry2_f20.jpg["FIGURE: Weights type drop-down list button",align="center"]
The drop-down list can then be used to select the type of weight system or the user may start
typing in the box which shows the available options for the entered characters. In
the *Weight*
field, the weight used during the dive must be typed. After typing the
information
for the weight system the user must either press _ENTER_ on the keyboard or
click outside the
cell that contains the cursor. It is possible to enter
information for more than one weight system by adding an additional system using
the + button on the top right hand. Weight systems can be deleted using the
dustbin icon on the left hand. Here is an example of information for a dive
with two types of weights: integrated and a weight belt:
image::images/WeightsDataEntry3_f20.jpg["FIGURE: A completed weights information table",align="center"]
There's NO need to click the _Save_ button before the dive
profile has been completed.
[[S_CreateProfile]]
==== Creating a Dive Profile
The *Dive Profile* (a graphical representation of the depth of the dive as a
function of time) is indicated in the panel on the top right hand of the
_Subsurface_ window. When a dive is manually added to a logbook, _Subsurface_
presents a default dive profile that needs to be modified to best represent the
dive being described:
image::images/DiveProfile1_f20.jpg["FIGURE: Initial dive profile",align="center"]
_Modifying the dive profile_: When the cursor is moved around the dive profile,
its position is indicated by two coloured lines (red and green) as shown below.
The depth and time
that the cursor represents are indicated at the top of the black information box
(@ and D). The units (metric/imperial) on the axes are determined by the
*Preference* settings. The dive profile itself comprises several
line segments demarcated by waypoints (white dots on the profile, as shown
above). The default dive depth is 15 m.
If the dive depth was 20 m then the user needs to drag the appropriate waypoints
downwards to represent 20 m. To add a waypoint, double-click on
any line segment. To move an additional waypoint, drag it.
To remove this waypoint, right-click on it and choose "Remove this point" from the
context menu. The user needs to drag the waypoints to represent an
accurate
time duration for the dive. Below is a dive profile that represents a dive
to 20 m for 30 min, followed by a 5 minute safety stop at 5 m.
image::images/DiveProfile2_f20.jpg["FIGURE: Edited dive profile",align="center"]
_Specifying the gas composition:_ The gas composition used is clearly indicated
along the line segments of the dive profile. This defaults to the first gas
mixture specified in the *Equipment* tab, which was air in the case of the
profile illustrated above. The gas mixtures of segments of the dive profile can
be edited. This is done by right-clicking on the particular
waypoint and selecting the appropriate gas from the context menu. Changing
the gas for a waypoint affects the gas shown in the segment _to the left_ of
that
waypoint. Note that only the gases defined in the *Equipment* tab appear in the
context menu.
image::images/DiveProfile3_f20.jpg["FIGURE: Gas composition context menu",align="center"]
Below is the profile of a dive to 25 m for 30 min and with a switch from air to
EAN50 at the end of the duration at 20m. In this case the first cylinder in the
*Equipment* tab contained air and the second cylinder contained EAN50.
image::images/DiveProfile4_f20.jpg["FIGURE: Completed dive profile",align="center"]
==== Saving the hand-entered dive information
The information entered in the *Dive Notes* tab, the *Equipment* tab as well as
the *Dive Profile* can now be saved in the user's logbook by using the two
buttons
on the top right hand of the Dive Notes tab. If the _Save_ button is clicked,
the dive data
are saved in the current logbook. If the _Cancel_ button is clicked, the newly
entered
dive data are discarded. When exiting _Subsurface_, the user will be prompted
once more to save the logbook with the new dive(s).
[[S_ImportDiveComputer]]
=== Importing new dive information from a Dive Computer
==== Connecting and importing data from a dive computer.
The use of dive computers allows the collection of a large amount of
information about
each dive, e.g. a detailed record of depth, duration, rates of ascent/descent
and of gas partial pressures. _Subsurface_ can capture this information and
present it as part of the dive information, using dive
information from a wide range of dive computers. The latest list of supported
dive computers can be found at:
link:http://subsurface-divelog.org/documentation/supported-dive-computers/[
Supported dive computers].
[icon="images/icons/warning2.png"]
[WARNING]
Several dive computers consume more power when they are in their
PC-Communication mode. **This could drain the dive computer's battery**. We
therefore
recommend that the user checks if the dive computer is charged when
connected to the USB port of a PC. For example, several Suunto and Mares dive
computers do not recharge through the USB connection. Users should refer to
the dive computer's manual
if they are unsure whether the dive computer recharges its batteries
while connected to the USB port.
To import dive information from a dive computer to a computer with
_Subsurface_,
it is necessary that the two pieces of equipment communicate with one another.
This
involves setting up the communications port (or mount point) of the computer
with _Subsurface_ that communicates with the dive computer. In order to set up
this communication, one needs to find the appropriate information to
instruct
_Subsurface_ where and how to import the dive information.
xref:_appendix_a_operating_system_specific_information_for_importing_dive_information_from_a_dive_computer[Appendix A]
provides the technical information to help the user achieving this for different
operating
systems and
xref:_appendix_b_dive_computer_specific_information_for_importing_dive_information[Appendix B]
has dive computer specific information.
After this, the dive computer can be hooked up to the user's PC, which can be
achieved by following these steps:
1. The interface cable should be connected to a free USB port (or the Infra-red
or Bluetooth connection set up as described later in this manual)
2. The dive computer should be placed into PC Communication mode.
(Users should refer to the manual of their specific dive computer)
3. In _Subsurface_, from the Main Menu, the user must select _Import -> Import
From Dive Computer_.
Dialogue *A* in the figure below appears:
image::images/DC_import_f20.jpg["FIGURE: Download dialogue 1",align="center"]
Dive computers tend to keep a certain number of dives in their memory, even
though these dives have already been imported to _Subsurface_. For that reason, if
the divecomputer allows this,
_Subsurface_ only imports dives that have not been uploaded before. This makes
the download process faster on most dive computers and also saves battery power
of the dive computer (at least for those not charging while connected via USB).
If, for some reason, the user wishes to import ALL dives from the dive computer,
even though some may already be in the logbook, then check the check box labelled
_Force download of all dives_.
- The dialogue has two drop-down lists, *Vendor* and *Dive Computer*. On the
*vendor* drop-down list select the make of the computer, e.g.
Suunto, Oceanic,
Uwatec, Mares. On the *Dive Computer* drop-down list, the model name of
the dive computer must be selected, e.g. D4 (Suunto), Veo200 (Oceanic), or Puck
(Mares).
- The *Device or Mount Point* drop-down list contains the USB or Bluetooth port
name that _Subsurface_ needs in order to communicate with the dive computer.
The appropriate port name must be selected. Consult
xref:_appendix_a_operating_system_specific_information_for_importing_dive_information_from_a_dive_computer[Appendix A]
and
xref:_appendix_b_dive_computer_specific_information_for_importing_dive_information[Appendix B]
for technical details on how to find the appropriate port information for a
particular dive
computer and, in some cases, how to do the correct settings to the operating
system of the computer on which _Subsurface_ is running.
- If all the dives on the dive computer need to be downloaded, check the
checkbox _Force download of all dives_. Normally, _Subsurface_ only downloads
dives after the date-time of the last dive in the *Dive List* panel. If one
or more of your dives in _Subsurface_ have been accidentally deleted or if there
are older dives that still need to be downloaded from the dive computer, this
checkbox needs to be activated. Some dive computers (e.g. Mares Puck) do not provide
a contents list to _Subsurface_ before the download in order to select only new dives.
Consequently, for these dive computers, all dives are downloaded
irrespective of the status of this check box.
- If the checkbox _Always prefer downloaded dives_
has been checked and, during download, dives with identical date-times exist on
the dive computer and on the _Subsurface_
*Dive List* panel, the dive in the _Subsurface_ divelog will be overwritten
by the dive record from the dive computer
- The checkbox marked _Download into new trip_ ensures that, after upload, the downloaded dives
are grouped together as a new trip(s) in the *Dive List*.
- Do *not* check the checkboxes labelled _Save libdivecomputer logfile_ and
_Save libdivecomputer dumpfile_. These are only used as diagnostic tools
when problems with downloads are experienced (see below).
- Then select the _Download_ button. After successful download, Dialogue *B*
in the figure above appears.
- With communication established, one can see how the data are
retrieved from the dive computer.
Depending on the make of the dive computer and/or number of recorded dives, this
could take some time. Be patient. The _Download_ dialogue
shows a
progress bar at the bottom of the dialogue (for some dive computers the
progress information could be inaccurate as we cannot determine how much
downloadable data there is until all data have been downloaded). When the
download of the dive information is complete, all the imported dives appear
in the *Dive List*, sorted by date and time. Disconnect and
switch off the dive
computer to conserve its battery power.
If a particular dive is selected, the *Dive Profile* panel shows an informative
graph of dive depth against time for that particular dive.
After the dives have been downloaded, they appear in a tabular format on the righthand
side of the dialogue (see image *B*, above). Each dive comprises a row in the table, with the date, duration
and depth shown. Next to each dive is a checkbox: check all the dives that need to
be transfered to the *Dive List*. In the case of the image above, the last six dives are
checked and will be transfered to the *Dive List*.
After this has been completed, select the OK button.
The checked dives are transfered to the *Dive List*.
- If there is a problem in communicating with the dive computer, an error
message will be shown, similar to this text: "Unable to open /dev/ttyUSB0 Mares
(Puck Pro)". Refer to the text in the box below.
****
*PROBLEMS WITH DATA DOWNLOAD FROM A DIVE COMPUTER?*
[icon="images/icons/important.png"]
[IMPORTANT]
Check the following:
- Is the dive computer still in PC-communication or
Upload mode?
- Is the battery of the dive computer fully charged? If not then the battery
must be charged or replaced.
- Is the connecting cable faulty? Does the cable work perfectly using other
software? Has it worked before, or is this the first time the cable is being used? Are the contacts
on the dive computer and the cable clean?
- Consult
xref:_appendix_a_operating_system_specific_information_for_importing_dive_information_from_a_dive_computer[Appendix A]
and make sure that the correct Mount Point
was specified (see above).
- On Unix-like operating systems, does the user have write permission to the
USB port? If not, consult
xref:_appendix_a_operating_system_specific_information_for_importing_dive_information_from_a_dive_computer[Appendix A]
If the _Subsurface_ computer does not recognise the USB adaptor by
showing an appropriate device name next to the Mount Point, then there is a
possibility that the cable or USB adaptor is faulty. A faulty cable is the most
common cause of communication failure between dive computer and _Subsurface_
computer. It is also possible that the _Subsurface_ computer cannot interpret
the data. Perform a download for diagnostic purposes with the following
two check boxes checked in the download dialogue discussed above:
Save libdivecomputer logfile
Save libdivecomputer dumpfile
*Important*: These check boxes are only used when problems are encountered
during the download process: under normal circumstances they should not be checked.
When checking these boxes, the user is prompted to select a folder to
save the information to. The default folder is the one in which the _Subsurface_
dive log is kept.
*Important:* _After downloading with the above checkboxes
checked, no dives are added to the
*Dive List* but two files are created in the folder selected above_:
subsurface.log
subsurface.bin
These files should be send to the _Subsurface_ mail list:
_subsurface@subsurface-divelog.org_ with a
request for the files to be analysed. Provide the dive computer
make and model
as well as contextual information about the dives recorded on the dive computer.
****
[[S_DeviceNames]]
==== Changing the name of a dive computer
It may be necessary to distinguish between different dive computers used to
upload dive logs to _Subsurface_. For instance if one's partner's dive computer is the
same make and model as one's own and dive logs are uploaded from both dive computers
to the same _Subsurface_ computer, then
one would perhaps like to call one dc "Alice's Suunto D4" and the other one
"Bob's Suunto D4". Alternatively, perhaps a technical diver dives with two or more
dive computers of the same model, the logs of both (or all) being uploaded.
In this case it might be prudent to call one of them
"Suunto D4 (1)" and another one "Suunto D4 (2)". This is easily done in _Subsurface_.
On the *Main Menu*, select _Log -> Edit device names_. A dialog opens, indicating the
current Model, ID and Nickname of the dive computers used for upload. Edit the Nickname
field for the appropriate dive computer. After saving the Nickname, the dive logs
show the nickname for that particular device instead of the model name,
allowing easy identification of devices.
[[S_EditDiveInfo]]
==== Updating the dive information imported from the dive computer.
With the uploaded dives in the *Dive List*, the information from the dive
computer is not complete and more details must be added in order to have
a fuller record of the dives. To do this,
the *Dive Notes* and the *Equipment* tabs on the top left hand of the
_Subsurface_ window should be used.
==== Dive Notes
The date and time of the dive, gas mixture and (often) water temperature are usually
shown as obtained from the dive computer, but the user needs to add
additional information by hand in order to have a more complete dive record. In a few cases,
(e.g. APD rebreathers) one also has to provide the date and time of the dive.
If the contents of this tab is changed or edited in any way, the message in a blue box at
the top of the panel indicates that the dive is being edited. If one
clicks on the *Dive Notes* tab, the following fields are
visible:
image::images/AddDive3_f20.jpg["FIGURE: The Dive Notes tab",align="center"]
The *Time* field reflects the date and time of the dive. By clicking
the date, a calendar is displayed from which
one can choose the correct date. Press ESC to close the calendar.
The time values (hour and minutes) can also be
edited directly by clicking on each of them in the text box and by overtyping the
information displayed.
*Air/water temperatures*: Air and water temperatures during the dive are shown
in these fields to the right of the Start time. Many dive computers supply water
temperature information and this field may therefore contain information obtained from the dive computer.
If air temperature is not provided by the dive computer, the first temperature reading
might be used for the air temperature. Generally this is close enough to the real air temperature as
the change in the temperature sensor reading is quite slow to follow the changes in the environment.
If editing is required, only a value is required, the units of temperature will be
automatically supplied by
_Subsurface_ (according to the _Preferences_, metric or imperial units will
be used).
*Location*: In this field one should type in text that describes the site
where the dive was performed, e.g. "Tihany, Lake Balaton, Hungary".
Auto completion of location names will
make this easier if one frequently dives at the same sites.
*Coordinates*: The geographic coordinates of the dive site should be entered
here. These can come from three sources:
a. The user can find the coordinates on the world map in the bottom right hand
part
of the Subsurface window. The map displays a green bar indicating "Move the map
and double-click to set the dive location". Double-click
at the appropriate place, the green bar disappears and the coordinates are
stored.
b. The user can obtain the coordinates from the _Subsurface_ Companion app if
an Android or iPhone device with GPS was used and if the coordinates of the dive site
were stored using that device.
xref:S_Companion[Click here for more information]
c. The coordinates can be entered by hand if they are known, using one of
four formats with latitude followed by longitude:
ISO 6709 Annex D format e.g. 30°13'28.9"N 30°49'1.5"E
Degrees and decimal minutes, e.g. N30° 13.49760' , E30° 49.30788'
Degrees minutes seconds, e.g. N30° 13' 29.8" , E30° 49' 1.5"
Decimal degrees, e.g. 30.22496 , 30.821798
Southern hemisphere latitudes are given with a *S*, e.g. S30°, or with a
negative value, e.g. -30.22496. Similarly, western longitudes are given with a
*W*, e.g. W07°, or with a negative value, e.g. -7.34323.
Please note that GPS coordinates of a dive site are linked to the Location
name - so adding coordinates to dives that do not have a location description
will cause unexpected behaviour (Subsurface will think that all of these
dives have the same location and try to keep their GPS coordinates the
same).
*Dive mode*: This is a dropdown box allowing one to choose the type of dive
performed. The options are OC (Open Circuit, the default seting, meant for most recreational dives),
Freedive (dive without SCUBA equipment), CCR (Closed-circuit
rebreather) and pSCR (Passive semi-closed rebreather).
*Divemaster*: The name of the dive master or dive guide for this dive should be
entered in this field
which offers auto completion based on the list of dive masters in
the current logbook.
*Buddy*: In this field, one enters the name(s) of the buddy / buddies
(separated with commas) who accompanied him/her on the
dive. Auto completion based on the list of buddies in the current logbook is
offered.
*Suit*: Here the type of diving suit used for the dive can be entered.
Auto completion of the suit description is available.
Some dry-suit users may choose to use this field to record what combination of
suit and thermal protection undersuit was used.
*Rating*: One can provide a subjective overall rating of the dive on a
5-point scale by clicking the appropriate star on the rating scale.
*Visibility*: Similarly, one can provide a rating of visibility during the
dive on a
5-point scale by clicking the appropriate star.
*Tags*: Tags that describe the type of dive performed can be entered
here (separated by commas). Examples of common tags are boat, drift, training,
cave, etc.
_Subsurface_ has many built-in tags. If the user starts typing a tag, the
program
will list the tags that correspond to the typing. For instance, if the user
typed
+cav+, then the tags *cave* and *cavern* are shown for the user to choose from.
*Notes*: Any additional information for the dive can be entered here.
The *Save* and *Cancel* buttons are used to save all the information for tabs
in the info panel and in the dive profile panel, so there's no need to use them
until ALL other information has been added. Here is an example of a completed
Dive Notes panel:
image::images/CompletedDiveInfo_f20.jpg["FIGURE: A completed Dive Notes tab",align="center"]
==== Equipment
The Equipment tab allows one to enter information about the type of
cylinder and gas used as well as the weights used for the dive. The
message in a blue box at the top of the panel:
image::images/BlueEditBar_f20.jpg["FIGURE: Blue edit bar",align="center"]
indicates that the dive is being edited. This is a highly interactive part of
_Subsurface_ and the information on
cylinders and gases (entered here) determines the behaviour of the dive profile
(top right-hand panel).
*Cylinders*: The cylinder information is entered through a dialogue that looks
like this:
image::images/DC_gas-dialogue1_f20.jpg["FIGURE: Initial cylinder dialogue",align="center"]
In most cases _Subsurface_ obtains the gas used from the dive computer and
automatically inserts the gas composition(% oxygen) in the table. The + button
at the top right allows the user to add more cylinders for this dive. The dark
dustbin icon on the left allows the deletion of information for a cylinder.
Note that it is not possible to delete a cylinder if it is used during the
dive. A cylinder might be implicitly used in the dive, even without a gas change event.
The user should start by selecting a cylinder type on the left-hand side of the
table. To select a cylinder, the *cylinder type* box should be clicked. This
brings up a list button that can be used to display a dropdown list of
cylinders:
image::images/DC_gas-dialogue2_f20.jpg["FIGURE: The cylinder drop-down list button",align="center"]
The drop-down list can then be used to select the cylinder type that was used
for this dive or the user may start typing in the box which shows the available
options for the entered characters. The
*Size* of the cylinder as well as its working pressure (*WorkPress*) will
automatically be shown in the dialogue.
Next one must indicate the starting pressure and the ending pressure of the
specified gas during the dive. The unit of pressure (metric/imperial)
corresponds to the settings chosen in the _Preferences_.
Finally, provide the gas mixture used. If air was used, the
value of 21% can be entered or this field can be left blank. If nitrox or
trimix were used, their percentages of oxygen and/or helium should be entered.
Any inappropriate fields should be left empty. After typing the
information for the cylinder,
either press _ENTER_ on the keyboard or click outside the cell
that contains
the cursor. Information for any additional cylinders can be added by using the +
button at the top right hand. Following is an example of a complete description
for a dive using two cylinders (air and EAN50):
image::images/CylinderDataEntry3_f20.jpg["FIGURE: a completed cylinder dive information table",align="center"]
*Weights*: Information about the weight system used can be entered
using a dialogue very similar to that of the cylinder information. If one
clicks
the + button on the top right of the weights dialogue, the table looks like
this:
image::images/WeightsDataEntry1_f20.jpg["FIGURE:The Weights dialogue",align="center"]
By clicking on the *Type* field, a drop-down list becomes accessible through a
down-arrow:
image::images/WeightsDataEntry2_f20.jpg["FIGURE:Weights type drop-down list button",align="center"]
The drop-down list can then be used to select the type of weight system
used during the dive or the user may start typing in the box
which shows the available options for the entered characters.
In the *Weight*
field, type in the amount of weight used during the dive. After
specifying the weight
system, the user can either press _ENTER_ on the keyboard or click outside the
cell with the cursor.
It is possible to enter information for more than one weight system by adding
an additional system
using the + button on the top right hand. Weight systems can be deleted using
the dustbin icon on the left hand. Here is an example of information for a dive
with two types of weights: integrated as well as a weight belt:
image::images/WeightsDataEntry3_f20.jpg["FIGURE: A completed weights information table",align="center"]
==== Editing several selected dives simultaneously
_METHOD 1_: After uploading dives from
a dive computer, the dive profiles of the uploaded dives are shown in the *Dive profile* tab, as well
as a few items of information
in the *Dive Notes* tab (e.g. water temperature) and in the *Equipment* tab (e.g. gas pressures
and gas composition). However the other fields remain empty.
It may be useful to simultaneously edit some of the
fields in the *Dive Notes* and *Equipment* tabs. For instance, it is possible
that a diver performed several dives during a single day, using identical equipment while diving at the same
dive site or with the same dive master and/or buddy or tags. Instead of completing the information for each
of these dives separately, one can select all the dives for that day in the *Dive List* and
insert the same information in the *Dive Notes* and *Equipment* fields that need
identical information. This is achieved by editing the dive notes or the equipment for any one
of the selected dives.
The simultaneous editing only works with fields that do not already contain information.
This means that, if some fields have been edited for a particular dive among the selected dives,
these are not changed while
editing the dives simultaneously. Technically, the rule for editing several dives simultaneously is:
if the data field being edited contains _exactly the same information_ for all the dives that have been
selected, the new, edited information is substituted for all the selected dives, otherwise only the
edited dive is
changed, even though several dives have been selected in the *Dive List*. This greatly speeds
up the completion of the dive log after several similar dives.
[[S_CopyComponents]]
_METHOD 2_:There is a different way of achieving the same goal. Select a dive with all the appropriate information
typed into the *Dive Notes* and *Equipment* tabs. Then, from the main menu, select _Log -> Copy dive components_.
A box is presented with a selection of check boxes for most of the fields in the *Dive Notes* and *Equipment* tabs.
Select the fields to be copied from the currently selected dive, then select _OK_. Now, in the *Dive List*,
select the dives
into which this information is to be pasted. Then, from the main menu, select _Log -> Paste dive components_.
All the selected dives now contain the data initially selected in the original source dive log.
==== Adding Bookmarks to a dive
Many divers wish to annotate their dives with text that indicate particular events
during the dive, e.g. "Saw dolphins", or "Released surface buoy". This is easily
done:
- Right-click at the appropriate point on the dive profile.
This brings up the dive profile context menu. Select _Add bookmark_. A red flag is
placed on the dive profile at the point that was initially selected (see *A* below).
- Right-click on the red flag. This brings up the context menu (see *B* below). Select _Edit name_.
- A text box is shown. Type the explanatory text for the bookmark (see *C* below). Select _OK_.
This saves the text associated with the bookmark.
- If one hovers using the mouse over the red bookmark, the appropriate text is shown at
the bottom of the information box (see *D* below).
image::images/Bookmarks.jpg["FIGURE: Bookmark dialog",align="center"]
==== Saving the updated dive information
The information entered in the *Dive Notes* tab and the *Equipment* tab can be
saved by
using the
two buttons on the top right hand of the *Dive Notes* tab. If the _Save_ button
is clicked,
the dive data are saved. If the _Cancel_ button is clicked, then the newly
entered dive data are
deleted, although the dive profile obtained from the dive computer will be
retained. When the user exits _Subsurface_ there is a final prompt to confirm
that the new data should be saved.
=== Importing dive information from other digital data sources or other data formats
[[S_ImportingAlienDiveLogs]]
If a user has been diving for some time, it is possible that several dives were
logged using other dive log software. This information does not need retyping
because these dive logs can probably be
imported into _Subsurface_. _Subsurface_ will import dive logs from a range of
other
dive log software. While some software is supported natively, for others the
user has to
export the logbook(s) to an intermediate format so that they can then be imported
by _Subsurface_.
Currently, _Subsurface_ supports importing CSV log files from several sources.
APD LogViewer, XP5, Sensus and Seabear files are
preconfigured, but because the import is flexible, users can configure their own
imports.
Manually kept log files (e.g. in spreadsheet) can also be imported by
configuring the CSV import.
_Subsurface_ can also import UDDF and UDCF files used by some divelog
software and some dive computers, like the Heinrichs & Weikamp DR5. Finally,
for some divelog software like Mares Dive Organiser it is currently suggested to
import the logbooks first into a webservice like _divelogs.de_ and then import
them from there with
_Subsurface_, as divelogs.de supports a few additional logbook formats that
_Subsurface_ currently cannot parse.
If the format of other software is supported natively on Subsurface, it should be sufficient to select
either _Import -> Import log files_ or _File -> Open log file_. _Subsurface_ supports the data formats
of many dive computers, including Suunto and Shearwater. When importing dives, _Subsurface_
tries to detect multiple records for
the same dive and merges the information as best as it can. If
there are no time zone issues (or other reasons that would cause the
beginning time of the dives to be significantly different) _Subsurface_
will not create duplicate entries.
==== Using the universal import dialogue
[[Unified_import]]
Importing dives from other software is performed through a universal interface
that is activated by selecting _Import_ from the Main Menu, then clicking on
_Import Log Files_. This brings up the dialogue *A* below.
image::images/Import1_f20.jpg["FIGURE: Import dialogue: step 1",align="center"]
Towards the bottom right is a dropdown selector with a default label
of _Dive Log Files_ which gives access to the different types of direct imports
available, as in dialogue *B*, above. Currently these are:
- XML-formatted dive logs (DivingLog 5.0, MacDive and several other dive log systems)
- UDDF-formatted dive logs (e.g. Kenozoooid)
- UDCF-formatted dive logs
- Poseidon MkVI CCR logs
- JDiveLog
- Suunto Dive Manager (DM3 and DM4)
- CSV (text-based and spreadsheet-based) dive logs, including APD CCR logs
Selecting the appropriate file in the file list of the dialogue opens
the imported dive log in the _Subsurface_ *Dive List*. Some other formats, not
accessible through the Import dialogue are also supported, as explained below.
==== Importing from Mares Dive Organiser V2.1
Since Mares utilise proprietary Windows software not compatible with
multi-platform applications, these dive logs cannot be
directly imported into
_Subsurface_. Mares dive logs need to be imported using a three-step process,
using _www.divelogs.de_ as a mechanism to extract the dive log information.
1. The dive log data from Mares Dive Organiser need to be exported to the user's
desktop, using
a _.sdf_ file name extension. Refer to xref:Mares_Export[Appendix C] for more
information.
2. Data should then be imported into _www.divelogs.de_. One needs to create a user
account in
_www.divelogs.de_, log into that web site, then
select _Import Logbook -> Dive Organiser_ from the menu on the left hand side.
The instructions must be carefully followed to transfer the dive information
(in _.sdf_ format) from the Dive Organiser database to _www.divelogs.de_.
3. Finally, import the dives
from _divelogs.de_ to _Subsurface_, using the instructions below.
[[S_ImportingDivelogsDe]]
==== Importing dives from *divelogs.de*
The import of dive information from _divelogs.de_ is simple, using a single
dialogue box. The _Import -> Import from Divelogs.de_ option should be selected
from the Main Menu. This
brings up a dialogue box (see figure on left [*A*] below). Enter a
user-ID and password for _divelogs.de_ into the appropriate fields and then
select
the _Download_ button. Download from _divelogs.de_ starts immediately,
displaying a progress bar in the dialogue box. At the end of the download, the
success status is indicated (see figure on the right [*B*], below). The
_Apply_ button should then be selected, after which the imported dives appear in the
_Subsurface_ *Dive List* panel.
image::images/Divelogs1.jpg["FIGURE:Download from Divelogs.de",align="center"]
[[S_ImportingCSVData]]
==== Importing data in CSV format
A comma-separated file (.csv) can be used to import dive information either as dive profiles
(as in the case of the APD Inspiration and Evolution closed circuit rebreathers) or as dive
metadata (in case the user keeps dive data in a spreadsheet). The _CSV_ format is a universal
simplified format that allows for easy information exchange between different computers or
software packages. For an introduction to CSV-formatted files see xref:S_CSV_Intro[A Diver's
Introduction To CSV Files]. _Subsurface_ dive logs can also be exported in _CSV_ format to
other software that reads this format. See xref:S_Appendix_D[APPENDIX D: Exporting a spreadsheet
to CSV format] for information that may be helpful for importing spreadsheet-based data
into _Subsurface_.
[[S_ImportingCSVDives]]
===== Importing dives in CSV format from dive computers or other dive log software
One can view a _CSV_ file by using an ordinary text editor. It is normally organised into
a single line that provides the headers (or _field names_ or _column headings_) of the data
columns, followed by the data, one record per line.
There are two types of _CSV_ dive logs that can be imported into _Subsurface_:
1. _CSV dive details_: This dive log format contains similar information to that of a
typical written dive log, e.g. dive date and time, dive depth, dive duration, names of
buddy and dive master and perhaps some information about cylinder pressures before and
after the dive, as well as a comment or two about the dive. All the data for a single
dive go on a single line of text, following the order of the column headings.
2. _CSV dive profile_: This dive log format includes much more information about a single
dive. For instance there may be information at 30-second intervals, indicating depth, water
temperature at that depth, and cylinder pressure at that moment in time. Each line contains
the information for a single instant in time during the dive, 30 seconds after that
of the previous instant. Many lines
are required to complete the depth profile information for a single dive. This is a common
export format used by closed-circuit rebreather (CCR) dive equipment and many software
packages that handle dive computer data and/or dive logs.
Before being able to import the _CSV_ data to _Subsurface_ *one needs to know a few
things about the data being imported*:
a. Which character separates the different columns within a single line of
data? This field separator should be either a comma (,) or a TAB character.
This can be determined by opening the file with a text editor. If it is
comma-delimited, then the comma
characters between the values are clearly visible. If no commas are evident and
the numbers are aligned in columns,
the file is probably TAB-delimited (i.e. it uses a TAB as a field separator).
b. Which data columns need to be imported into _Subsurface_? Is it a _CSV dive details_
file or a _CSV dive profile_ file? Open the file using a text editor and note
the titles of the columns to be imported and their column positions.
c. Is the numeric information (e.g. dive depth) in metric or in imperial unis?
Armed with this information, importing the data into _Subsurface_ is
straightforward. Select
_Import -> Import Log Files_ from the main menu. In the resulting file
selection menu, select _CSV files_ (towards the bottom right). This shows all .CSV files in the selected
directory. Select the file that needs to be imported. A configuration panel
appears as depicted below:
image::images/csv_import1_f20.jpg["FIGURE: CSV download dialogue 1",align="center"]
Notice that, at the top left, there is a dropdown list containing pre-configured
settings for some of the more common dive computers and software packages
encountered by divers. If the _CSV_ file being imported originated from any of
these pre-configured items, then select it. Otherwise use the _Manual Import_
option. The configuration panel also has dropdown lists for the specification of the appropriate
field separator (Tab, comma or semicolon), the date format used in the _CSV_ file,
the time units (seconds, minutes or minutes:seconds), as well as the unit system
(metric or imperial). Selecting the appropriate options among these is critical for
the successful import of the data.
The last remaining task is to ensure that all the data columns have the appropriate
column headings. The top line of the white part of the data table contains the column
headings found in the _CSV_ data file. The blue row of cells immediately above these
contains the names understood by _Subsurface_. The white area below the dropdown
lists contains all the field names that _Subsurface_ recognises. These names are
in blue balloons and can be moved using a drag-and-frop action. For
instance, _Subsurface_ expects the column heading for Dive number (" # ") to be "Dive # ". If
the column heading that _Subsurface_ expects is not in the blue cells, then drag the
appropriate column heading from the upper area and drop it in the appropriate blue
cell at the top of the table. To indicate the correct column for "Dive #", drag
the ballooned item labelled "Dive # " and drop it in the blue
cell immediately above the white cell containing " # ". This is depicted in
the image below.
image::images/csv_import2_f20.jpg["FIGURE: CSV download dialogue 2",align="center"]
Continue in this way to ensure that all the column headings in the blue row of
cells correspond to the headings listed in the top part of the dialogue. Having
completed this task, select the _OK_ button to the bottom right og the dialogue.
The data from the _CSV_ file are imported and shown in the *Dive List* panel.
[[S_CSV_Intro]]
****
*A Diver's Introduction to _CSV_ Files*
[icon="images/icons/important.png"]
[IMPORTANT]
_CSV_ is an abbreviation for a data file format: _Comma-Separated Variables_. It is a
file format allowing someone to view or edit the information using a text editor such
as Notebook (Windows), gedit (Linux) or TextWrangler (OS/X). The two main advantages of
the _CSV_ format is that the data are easily editable as text without any proprietary software
and ensuring all information is human-readable, not being obscured by any custom or
proprietary attributes that proprietary software insert into files.
Because of its simplicity the _CSV_ format is used
as an interchange format between many software packages, e.g. between
spreadsheet, statistical, graphics, database and diving software. Within _Subsurface_, _CSV_ files can also
be used to import information from other sources such as spreadsheet-based dive logs and
even from some dive computers.
_CSV_ files can be created or edited with a normal text editor. The most important attribute of a
_CSV_ file is the _field separator_, the character used to separate fields within a single line. The
field separator is frequently a comma, a colon, a SPACE character or a TAB character. When exporting data from
spreadsheet software, the field separator needs to be specified in order to create the _CSV_ file. _CSV_ files are
normally organised into a single line that provides the headers (or _field names_) of the data columns,
followed by the data, one record per line. Note that each field name
may comprise more than one word separated by spaces; for instance _Dive site_, below. Here is an example of
dive information for four dives using a comma as a field separator:
Dive site,Dive date,Time,Dive_duration, Dive_depth,Dive buddy
Illovo Beach,2012-11-23,10:45,46:15,18.4,John Smith
Key Largo,2012-11-24,09:12,34:15,20.4,Jason McDonald
Wismar Baltic,2012-12-01,10:13,35:27,15.4,Dieter Albrecht
Pulau Weh,2012-12-20,09:46,55:56,38.6,Karaeng Bontonompo
In this format the data are not easily read by a human. Here is the same information in TAB-delimited format:
Dive site Dive date Time Dive_duration Dive_depth Dive buddy
Illovo Beach 2012-11-23 10:45 46:15 18.4 John Smith
Key Largo 2012-11-24 09:12 34:15 20.4 Jason McDonald
Wismar Baltic 2012-12-01 10:13 35:27 15.4 Dieter Albrecht
Pulau Weh 2012-12-20 09:46 55:56 38.6 Karaeng Bontonompo
It is clear why many people prefer the TAB-delimited format to the comma-delimited format. The
disadvantage is that one cannot see
the TAB characters. For instance, the space between _Dive_ and _date_ in the top line may be
a SPACE character or a TAB character (in this case it is a SPACE character: the tabs are before and
after _Dive date_). If the field names in the first line are long, the alignment with data in the other lines
cannot be maintained. Here is a highly simplified and shortened TAB-delimited example of a _CSV_ dive log
from an APD closed-circuit rebreather (CCR) dive computer:
Dive Time (s) Depth (m) pO₂ - Setpoint (Bar) pO₂ - C1 Cell 1 (Bar) Ambient temp. (Celsius)
0 0.0 0.70 0.81 13.1
0 1.2 0.70 0.71 13.1
0 0.0 0.70 0.71 13.1
0 1.2 0.70 0.71 13.2
0 1.2 0.70 0.71 13.1
10 1.6 0.70 0.72 12.7
20 1.6 0.70 0.71 12.6
30 1.7 0.70 0.71 12.6
40 1.8 0.70 0.68 12.5
When a _CSV_ file is selected for import, _Subsurface_ displays the column headers as well as some of the data
in the first few lines of the _CSV_ file, making it much easier to work with _CSV_ files.
_CSV_ files can therefore be used in many contexts for importing data into a _Subsurface_ dive log.
Knowledge of a few basic things about the content of the _CSV_ file allows a smooth import
of the dives into _Subsurface_.
****
[icon="images/icons/important.png"]
[IMPORTANT]
The _CSV_ import has a couple of caveats. One should avoid some special characters
like ampersand (&), less than (<), greater than (>) and double quotes (") as part
of the numbers or text within a cell. The
file should use UTF-8 character set, if using non-ASCII characters. Also the
size of the _CSV_ file might cause problems. Importing 100 dives at a time
(_CSV dive details_) works, but larger files might exceed
limits of the parser used. When encountering problems with _CSV_ imports, first try with
a smaller file to make sure everything works.
[[S_Companion]]
=== Importing GPS coordinates with the _Subsurface Companion App_ for mobile phones
Using the *Subsurface Companion App* on an Android device with a GPS or
iPhone, the coordinates
for the diving
location can be automatically passed to the _Subsurface_
dive log. The Companion App stores the dive locations on
a dedicated Internet-based file server. _Subsurface_, in turn, can collect
the localities from the file server.
To do this:
==== Create a Companion App account
- Register on the http://api.hohndel.org/login/[_Subsurface companion web page_].
A confirmation email with instructions and a personal *DIVERID* will be sent,
a long number that gives access to the file server and Companion App capabilities.
- Download the app from
https://play.google.com/store/apps/details?id=org.subsurface[Google Play Store]
or from
http://f-droid.org/repository/browse/?fdfilter=subsurface&fdid=org.subsurface[F-Droid].
==== Using the Subsurface companion app on an Android smartphone
On first use the app has three options:
* _Create a new account._ Equivalent to registering in _Subsurface_ companion
page using an Internet browser. One can request a *DIVERID* using this option,
but this is supplied via email and followed up by interaction with the
http://api.hohndel.org/login/[_Subsurface companion web page_] in order to
activate the account.
* _Retrieve an account._ If users forgot their *DIVERID* they will receive an email
to recover the number.
* _Use an existing account._ Users are prompted for their *DIVERID*. The app saves
this *DIVERID* and does not ask for it again unless one uses the _Disconnect_ menu
option (see below).
[icon="images/icons/important.png"]
[IMPORTANT]
In the _Subsurface_ main program, the *DIVERID* should also be entered on the
Default Preferences
panel, obtained by selecting _File -> Preferences -> Defaults_ from the main menu
in _Subsurface_ itself.
This facilitates synchronisation between _Subsurface_ and the Companion App.
===== Creating new dive locations
Now one is ready to get a dive position and
send it to the server. The Android
display will look like the left hand image (*A*) below, but without any dives.
Touch the "+" icon on the top right to add a new dive site, a menu will be
showed with 3 options:
* Current: A prompt for a place name (or a request to activate the GPS if it is turned
off) will be displayed, after which the current location is saved.
* Use Map: This option allows the user to fix a position by searching a world map. A
world map is shown (see *B* below) on which one should indicate the desired position
with a _long press_ on the touch
sensitive screen (if the marked location is erroneous, simply indicate a new location)
and select the check symbol in the upper right. A dialog is shown allowing to enter the
name of the dive location and the date-time of the dive (see *C* below). In order to import this
dive location in _Subsurface_ it's advisable to set the time to agree with the time of
that dive on the dive computer.
image::images/Companion_5.jpg["FIGURE: Companion App, add location using map",align="center"]
* Import local GPX file: The android device searches for .gpx files and located
archives will be shown. The selected .gpx file is opened and the stored
locations shown. Now one needs to select the appropriate locations, then select the
tab in the upper right, after which the locations will be sent to the web service
and added to the list on the Android device.
===== Dive lists of dive locations
The main screen shows a list of dive locations, each with a name, date and
time (see *A* below). Some locations may have an arrow-up icon over the selection box to the left
indicating that they require upload to the server. One
can select individual dive locations from the list. A selected location has a
check mark in the selection box on the left. Group operations (such as _Delete_ or _Send_)
are performed on several locations that are selected.
Dive locations in this list can be viewed in two ways: a list of locations or a
map indicating the dive locations. The display mode (List or Map) is changed by
selecting _Dives_ at the top left of the screen (see *A* below) and then selecting
the display mode. The display mode can be changed either from the list
of locations or from the map (see *B* below). If one selects a location (on the list
or on the map), an editing
panel opens (see *C* below) where the dive description or other details may be changed.
image::images/Companion_4.jpg["FIGURE: Companion App, add location using map",align="center"]
When one clicks on a dive (*not* selecting the check box), the
name given to it, date/time and GPS coordinates will be shown, with two options at the top
of the screen:
- Edit (pencil): Change the text name or other characteristics of the dive location.
- Maps: Display a map showing the dive location.
After editing and saving a dive location (see *C* above), one needs to upload it to the web
service, as explained below.
===== Uploading dive locations
There are several ways to send locations to the server.
The easiest is by simply
selecting the locations (See *A* below) and then touching the right arrow at the
top right of the screen.
[icon="images/icons/important.png"]
[IMPORTANT]
Users must be careful, as the trash icon on the right means exactly what it should;
it deletes the selected dive location(s).
image::images/Companion_1.jpg["FIGURE: Screen shots (A-B) of companion app",align="center"]
After a dive trip using the Companion App, all dive locations are ready to be
downloaded to a _Subsurface_ dive log (see below).
===== Settings on the Companion app
Selecting the _Settings_ menu option results in the right hand image above (*B*).
===== Server and account
- _Web-service URL._ This is predefined (http://api.hohndel.org/)
- _User ID._ The DIVERID obtained by registering as described above. The easiest way to
obtain it is simply to copy and paste from the confirmation email but, of
course, users can also type this information.
===== Synchronisation
- _Synchronize on startup._ If selected, dive locations in the Android device and those
on the web service synchronise each time the app is started.
- _Upload new dives._ If selected, each time the user adds a dive location it is
automatically sent to the server.
===== Background service
Instead of entering a unique dive location, users can leave the service running
in the background of their Android device, allowing the continuous collection of GPS locations.
The settings below define the behaviour of the service:
- _Min duration._ In minutes. The app will try to get a location every X minutes
until stopped by the user.
- _Min distance._ In meters. Minimum distance between two locations.
- _Name template._ The name the app will use when saving the locations.
[icon="images/icons/info.jpg"]
[TIP]
_How does the background service work?_ Assuming the user sets 5 minutes and 50
meters in the settings above, the app will start by recording a location at the current
location, followed by another one at every 5 minutes *or* every time one moves 50m
from previous location.
If subsequent locations are within a radius of 50 meters from the previous one,
a new location is not saved. If the user is not moving, only one location is saved,
but if the user is moving, a trace of the route is obtained by saving a
location every 50 meters.
===== Other
- _Mailing List._ The mail box for _Subsurface_. Users can send an email to the
Subsurface mailing list.
- _Subsurface website._ A link to the URL of Subsurface web
- _Version._ Displays the current version of the Companion App.
===== Search
Search the saved dive locations by name or by date and time.
===== Start service
Initiates the _background service_ following the previously defined settings.
===== Disconnect
This is a badly named option that disconnects the app from the server by
resetting the user ID in the app, showing the first screen where an account
can be created, retrieve the ID for an existing account or use the users own
ID. The disconnect option
is useful if a user's Android device was used to download the dive locations
of another registered diver.
===== Send all locations
This option sends all locations stored in the Android device to the server.
==== Using the Subsurface companion app on an iPhone smartphone
The iPhone interface is quite simple. One needs to add the user ID given
during the registration to the space reserved for it as shown on left
part of the image below.
image::images/iphone.png["FIGURE: Using iPhone companion application",align="center",width=640]
Next step is to click "Dive in" and start collecting location
information. Dive can be added automatically or manually. The difference
seems to be whether user is asked for site name or not. When user adds a
dive, location service is started and there is a red bar at the bottom
of the screen indicating that. After the dive one can click on the red
bar to end the dive/location service. Note that when the location
service is running, one can add dives only manually.
It is possible to change the site name afterwards by selecting the dive
in question from the dive list and clicking on the site name. Other
modifications doesn't seem to be possible. The dive list is uploaded
automatically to webservice and there does not seem to be an option to
trigger it manually.
==== Downloading dive locations to the _Subsurface_ divelog
Download dive(s) from a dive computer or enter them manually into
_Subsurface_ before obtaining the GPS coordinates from the server. The download
dialog can be reached via _Ctrl+G_ or from the _Subsurface_ Main Menu _Import
-> Import GPS data from Subsurface Service_, resulting in the image on the
left (*A*), below. On first use the DIVERID text box is blank. Provide a
DIVERID, then select the _Download_ button to initiate the download process, after
which the screen on the right (*B*) below appears:
image::images/DownloadGPS.jpg["FIGURE: Downloading Companion app GPS data",align="center"]
Note that the _Apply_ button is now active. By clicking on it, users can update the locations
of the newly entered or uploaded dives in _Subsurface_ which applies the
coordinates and names entered on the app for all the new dives that match the
date-times of the uploaded GPS localities. If one has entered the name of the dive
location in _Subsurface_ before downloading the GPS coordinates, this name will take
precedence over downloaded one.
Since _Subsurface_ matches GPS locations from the Android device and dive information from the
dive computer based on date-time data, automatic assignment of GPS data to dives is dependent
on agreement of the date-time information between these two devices. Although _Subsurface_ has
a wide range tolerance, it may be unable to identify the appropriate dive if there is
a large difference between the time in the dive computer and that of the Android device,
resulting in no updates.
Similar date-times may not always be possible and there may be many reasons for this (e.g. time zones), or
_Subsurface_ may be unable to decide which is the correct position for a dive (e.g. on repetitive
dives while running _background service_ there may be several locations that would be
included in the time range that fit not only the first dive, but one or more subsequent dives as well).
A workaround for this situation to manually edit the date-time of a dive in the _Subsurface_
Dive List *before* downloading the GPS data and then to change the date-time back again *after*
downloading GPS data.
[icon="images/icons/info.jpg"]
[NOTE]
TIPS:
- _Background service_, being a very powerful tool, may fill the location list with
many unnecessary locations not corresponding to the exact dive point but reflecting the boat's route.
Currently these locations are difficult to delete from the server. In some situations it
is therefore prudent to clean up the list on the Android device before sending the dive points to the web
server by simply deleting the inappropriate locations. This might be necessary, for
instance, if one wants to keep the location list clear to see dives in the web service map display (see above).
- It may also make sense to give informative names to the locations sent to the web server, or at least
to use an informative name in the _Name Template_ setting while running the _background service_,
especially on a dive trip with many dives and dive locations.
[[S_LoadImage]]
=== Adding photographs to dives
Many (if not most) divers take a camera with them and take photographs
during a dive. One would like to associate each photograph with a specific
dive. _Subsurface_ allows one to load photos into a dive. Photos are superimposed
on the dive profile, from where they can be viewed.
==== Loading photos and getting synchronisation between dive computer and camera
Left-lick on a dive or on a group of dives on the dive list. Then right-click on this
dive or group of dives and choose the option _Load Images_:
image::images/LoadImage1_f20.jpg["FIGURE: Load images option",align="center"]
The system file browser appears. Select the folder and photographs that need
to be loaded into _Subsurface_ and click the _Open_ button.
image::images/LoadImage2_f20.jpg["FIGURE: Load images option",align="center"]
This brings one to the time synchronisation dialog, shown below. The
critical problem is that the time
synchronisation is not perfect between the dive computer used during a dive,
and the camera used during that same dive. These two devices
often differ by several minutes. If _Subsurface_ can achieve synchronisation,
then the exact times of photographs can be used to position photographs on
the dive profile.
_Subsurface_ achieves this synchronisation in two ways:
- *Manually*: If the user wrote down the exact camera time at the start of a dive, the
difference in time between the two devices can be determined. Actually, as long as the device
settings for time has not been changed in either device, one could write down the times of
both devices after the dive or even at the end of the day. One can then manually set the time
difference in the _Time shift_ dialog. Towards the top of the dialog is a time setting tool
immediately under the heading _Shift times of image(s) by_, evident in figure *A* below.
If the camera time is 7 minutes later than that of the dive computer, set the time setting
tool to a value of 00:07. Select either the _earlier_ or _later_ radio button.
In the above example, the _earlier_ option is appropriate, since the photos need to be shifted
7 minutes earlier (camera is 7 minutes ahead of dive computer). Ignore any "AM" or "PM" suffix
in that tool. Click the _OK_ button and synchronisation is achieved.
image::images/LoadImage3b_f20.jpg["FIGURE: Synchronisation dialog",align="center"]
- *By photograph*: There is a very slick way of achieving synchronisation. If one takes a
photograph of the face of the dive computer showing the time, then _Subsurface_ can obtain
the exact time the photograph was taken, using the metadata that the camera stores within
each photo. In order to do this, use the bottom half of the Time shift_ dialog. If one uses
the bottom part, the top part of the dialog is ignored. Click on
the horizontal bar entitled "_Select image of divecomputer showing time_. This brings up
a file browser with which one can select the photograph of the dive computer. Select the
photograph using the file browser and click on _OK_. This photograph of the dive computer
appears in the bottom panel of the _Shift times_ dialog. Now _Subsurface_ knows exactly
when the photograph has been taken. Now set the date-time dialog to the left of the photo
so that this tool reflects the date and time of the dive computer in the photo. When the
date-time tool has been set, _Subsurface_ knows exactly what the time difference between
camera and dive computer is, and synchronisation is achieved. There is a
photograph with the face of the dive computer and with the date-time tool set to the
date-time on image *B* above.
If the timestamp of a photograph is long before or after the dive, it is not placed on
the dive profile. If the timestamp of the photo is within 30 minutes of the dive, it is shown.
==== Viewing the photos
In order to view the photos added to a dive, activate the _show-photos_ button in the tool bar
to the left of the dive profile:
image::images/icons/ShowPhotos_f20.png["FIGURE:Show photos toolbar button",align="left"]
After the images have been loaded, they appear in two places:
- the _Photos_ tab of the *Dive Notes* panel.
- as tiny icons (stubs) on the dive profile at the appropriate positions reflecting the time
each photograph was taken. See below:
image::images/LoadImage4_f20.jpg["FIGURE: Photos on dive profile",align="center"]
If one hovers with the mouse over any of the photo icons, then a thumbnail photo
is shown of the appropriate photo. See the image below:
image::images/LoadImage5_f20.jpg["FIGURE:Thumbnail photo on dive profile",align="center"]
Clicking on the thumbnail brings up a full size
photo overlaid on the _Subsurface_ window. This allows good viewing of
the photographs that have been added (see the image below). Note that the thumbnail
has a small dustbin icon in the bottom right hand corner (see image above). If one selects
the dustbin, the image is removed from the dive. Therefore some care
is required when clicking on a thumbnail. Images
can also be deleted using the _Photos_ tab (see text below).
image::images/LoadImage6_f20.jpg["FIGURE: Full-screen photo on dive profile",align="center"]
==== The _Photos_ tab
Photographs associated with a dive are shown as thumbnails in the _Photos_ tab of the _Dive Notes_
panel. Photos taken in rapid succession during a dive (therefore sometimes with large
overlap on the dive profile) can easily be accessed in the _Photos_ tab. This tab serves as
a tool for individually accessing the photos of a dive, while the stubs on the dive profile
give an indication of when during a dive a photo was taken. By single-clicking on a thumbnail in
the _Photos_ panel, a photo is selected. By double-clicking a thumbnail, the full-sized image is
shown, overlaying the _Subsurface_ window. A photo can be deleted from the _Photos_ panel by selecting
it (single-click) and then by pressing the _Del_ key on the keyboard. This removes the photo both
from the _Photos_ tab as well as the dive profile.
==== Photos on an external hard disk
Most underwater photographers store their photos on an external drive. If such a drive can be mapped
(almost always the case) the photos can be directly accessed by _Subsurface_. This facilitates the interaction
between _Subsurface_ and an external repository of photos. When associating a dive profile with photos from an
external drive, the normal procedure of selection and synchronisation (see text above) is used.
However, after the external drive has been disconnected, _Subsurface_ cannot access these photos any more.
If the display of photos is activated (using the toolbox to the left of the _Dive Profile_), the
program only shows a small white dot where each photo should be on the dive profile.
In addition the _Photos_ tab only shows the file names of the photos. This is normal behaviour.
If, later, the external drive with the photos is connected again, the photos can be seen in the normal way.
=== Logging special types of dives
==== Sidemount dives
_Subsurface_ easily handles dives involving more than one cylinder. Sidemount dive logging involves
three steps:
- *During the dive, recording cylinder switch events*. Since sidemount diving normally involves two
cylinders with air or with the same gas mixture, _Subsurface_ distinguishes among these different
cylinders. In contrast, most dive computers that allow gas switching only distinguish among different
_gases_ used, not among different _cylinders_ used. This means that when sidemount dives are downloaded
from these dive computers, the events of switching between cylinders with the same gas are not downloaded. This may mean
that one may have to keep a written log of cylinder switch times using a slate, or (if the dive computer
has this facility) marking each cylinder switch with a bookmark that can be retrieved later. Returning
from a dive with the information about cylinder changes is the only tricky part of logging sidemount dives.
- *Within _Subsurface_ describe the cylinders used during the dive*. The diver needs to provide the
specifications of the different cylinders, using the *Equipment* tab of the *Dive Info Panel* (see
image below where two 12 litre cylinder were used).
- *Indicate cylinder change events on the _Subsurface_ dive profile*. Once the dive log has been imported
from a dive computer into _Subsurface_, the cylinder switch events need to be indicated on the dive profile.
Cylinder changes are recorded by right-clicking at the appropriate point on the dive profile and then
selecting _Add gas change_. A list of the appropriate cylinders is shown with the
currently used cylinder greyed out. In the image below Tank 1 is greyed out, leaving only Tank 2
to be selected. Select the appropriate cylinder. The cylinder change is then indicated on the dive
profile with a cylinder symbol. If the *Tank Bar* is activated using the toolbar to the left of the
profile, then the cylinder change is also indicated on the Tank Bar (see image below). After all
the cylinder change events have been recorded on the dive profile, the correct cylinder pressures
for both cylinders are shown on the dive profile, as inthe image below.
image::images/sidemount1.jpg["FIGURE: Sidemount profile",align="center"]
This section gives an example of the versatility of _Subsurface_ as a give logging tool.
[[S_CCR_dives]]
==== Closed circuit rebreather (CCR) dives
[icon="images/APD.jpg"]
[NOTE]
Closed system rebreathers use advanced technology to recirculate
gas that has been breathed while doing two things to maintain a
breathable oxygen concentration:
a) remove carbon dioxide from the gas that has been exhaled
b) regulate the oxygen concentration to remain within safe diving limits.
Currently, within _Subsurface_, the Poseidon MkVI Discovery is the best
supported CCR dive computer. The CCR interface of _Subsurface_ is currently experimental
and under active development. In contrast to a conventional recreational
dive computer, a CCR system computer does not allow the download of a log
containing multiple dives. Rather, each dive is stored independently. This
means that _Subsurface_ cannot download a dive log directly from a CCR
dive computer, but that it imports CCR dive logs in the same way that it
imports dive log data from other digital databases.
===== Import a CCR dive
See the section dealing with xref:S_ImportingAlienDiveLogs[Importing dive information from other
digital sources]. From the main menu of _Subsurface_, select _Import -> Import
log files_ to bring up the xref:Unified_import[universal import dialogue]. As
explained in that section, the bottom right
hand of the import dialogue contains a dropdown list of appropriate devices
that currently includes an option for (Poseidon) MkVI files (import for other
CCR equipment is under active development). Having selected the appropriate CCR format and
the directory where the original dive logs have been stored from the CCR dive
computer, one can select a particular dive log file (in the case of the MkVI
it is a file with a .txt extension). After selecting the appropriate dive log,
activate the _Open_ button at the bottom right hand of the universal import dialogue.
===== Displayed information for a CCR dive
_Partial pressures of gases_: The graph of oxygen partial pressure shows the
information from the oxygen sensors of the CCR equipment. In contrast to recreational
equipment (where pO~2~ values are calculated based on gas composition and dive depth),
CCR equipment provide actual measurements of pO~2~, derived from oxygen sensors.
In this case the graph for oxygen partial pressure
should be fairly flat, reflecting the setpoint settings during the dive. The mean
pO~2~ is NOT the mean oxygen partial pressure as given by the CCR equipment, but
a value calculated by _Subsurface_ as follows:
- For TWO O~2~ sensors the mean value of the two sensors are given.
- For THREE-sensor systems (e.g. APD), the mean value is also used. However
differences of more than 0,1 bar in the simultaneous readings of different sensors are
treated as spurious. If one of the three sensors provides spurious data, it is ignored.
- If no sensor data is available, the pO~2~ value is assumed to be equal to the setpoint.
The mean pO~2~ of the sensors is indicated with a green line,
The oxygen setpoint values as well as the readings from the individual
oxygen sensors can be shown. The display of additional CCR information is turned on by
checking the appropriate checkboxes in the _Preferences_ panel (accessible by
selecting xref:S_CCR_options[_File -> Preferences -> Graph_]). This part of
the _Preferences_ panel look like this, representing two checkboxes that modify
the display of pO~2~ when the appropriate toolbar button on the Dive Profile
has been activated.
image::images/CCR_preferences_f20.jpg["FIGURE: CCR preferences panel",align="center"]
Checking any of the check boxes allows the display of additional oxygen-related
information whenever the pO~2~ toolbar button on the _Profile_ panel is activated.
The first checkbox allows the display of setpoint information. This is a red line
superimposed on the green oxygen partial pressure graph and allows a comparison of the
mean measured oxygen partial pressure and the setpoint values, as in the image below.
image::images/CCR_setpoint_f20.jpg["FIGURE: CCR setpoint and po2 graph",align="center"]
The second checkbox allows the display of the data from each individual oxygen sensor
of the CCR equipment. The data for each sensor is colour-coded as follows:
- Sensor 1: grey
- Sensor 2: blue
- Sensor 3: brown
The mean oxygen pO~2~ is indicated by the green line. This allows the direct comparison
of data from each of the oxygen sensors, useful for detecting abnormally low or erratic
readings from a particular sensor.
image::images/CCR_sensor_data_f20.jpg["FIGURE: CCR sensor data graph",align="center"]
The setpoint data can be overlaid on the oxygen sensor data by activating both of the above
check boxes. Partial pressures for nitrogen (and helium, if applicable) are shown in the
usual way as for open circuit dives.
_Events_: Several events are logged, e.g. switching the mouthpiece to open circuit.
These events are indicated by yellow triangles and, if one hovers over a triangle,
a description of that event is given as the bottom line in the xref:S_InfoBox[Information Box].
_Cylinder pressures_: Some CCR dive computers like the Poseidon MkVI record the
pressures of the oxygen and diluent cylinders. The pressures of these two cylinders
are shown as green lines overlapping the depth profile. In addition, start and
end pressures for both oxygen and diluent cylinders are shown in the _Equipment Tab_.
Below is a dive profile for a CCR dive, including an overaly
of setpoint and oxygen sensor data, as well as the cylinder pressure data. In this
case there is good agreement from the readings of the two oxygen sensors.
image::images/CCR_dive_profile_f20.jpg["FIGURE: CCR dive profile",align="center"]
_Equipment-specific information_: Equipment-specific information gathered by
_Subsurface_ is shown in the xref:S_ExtraTab[Extra data tab]. This may include setup information
or metadata about the dive.
More equipment-specific information for downloading CCR dive logs for
Poseidon MkVI and APD equipment can be found in xref:S_PoseidonMkVI[Appendix B].
== Obtaining more information about dives entered into the logbook
=== The *Dive Info* tab (for individual dives)
The Dive Info tab gives some summary information about a particular dive that
has been selected in the *Dive List*. Useful information here includes the
surface interval before the dive, the maximum and mean depths of the dive, the
gas volume consumed, the surface air consumption (SAC) and the number of oxygen
toxicity units (OTU) incurred.
[icon="images/icons/info.jpg"]
[NOTE]
Gas consumption and SAC calculations:
_Subsurface_ calculates SAC and Gas consumption taking in account gas
incompressibility, particularly at tank pressures above 200 bar, making them more accurate.
Users should refer to xref:SAC_CALCULATION[Appendix D] for more information.
=== The *Extra Data* tab (usually for individual dives)
When using a dive computer, it often reports several data items that cannot easily be
presented in a standardised way because the nature of the information differs from one
dive computer to another. These data often comprise setup information, metadata about
a dive, battery levels, no fly times, or gradient factors used during the dive. When
possible, this information is presented in the *Extra Data* tab. Below is an
image showing extra data for a dive using a Poseidon rebreather.
image::images/ExtraDataTab_f20.jpg["FIGURE: Extra Data tab",align="center"]
=== The *Stats* tab (for groups of dives)
The Stats tab gives summary statistics for more than one dive, assuming that
more than one dive has been selected in the *Dive List* using the standard
Ctrl-click or Shift-click of the mouse. If only one
dive has been selected, figures pertaining to only that dive are given. This tab
shows the number of dives selected, the total amount of dive time in these
dives,
as well as the minimum, maximum and mean for the dive duration,
water temperature and surface air consumption (SAC). It also shows the depth of the
shallowest and deepest dives of those selected.
[[S_DiveProfile]]
=== The *Dive Profile*
image::images/Profile2.jpg["Typical dive profile",align="center"]
Of all the panels in _Subsurface_, the Dive Profile contains the most detailed
information about each dive. The Dive Profile has a *button bar* on the left hand side
that allows control over several display options. The functions of these
buttons are described below. The main item in the Dive
Profile is the graph of
dive depth as a function of time. In addition to the obvious information of
the depth it also shows the ascent and descent rates compared to the recommended
speed of going up or down in the water column. This information is given using
different colours:
|====================
|*Colour*|*Descent speed (m/min)*|*Ascent speed (m/min)*
|Red|> 30|> 18
|Orange|18 - 30|9 - 18
|Yellow|9 - 18|4 - 9
|Light green|1.5 - 9|1.5 - 4
|Dark green|< 1.5|< 1.5
|=====================
The profile also includes depth readings for the peaks and troughs in the graph.
Thus, users should see the depth of the deepest point and other peaks. Mean depth
is marked with a horizontal red line.
[icon="images/icons/scale.jpg"]
[NOTE]
In some cases the dive profile does not fill the whole area of the *Dive Profile*
panel. Clicking the *Scale* button in the toolbar on the left of the dive profile
frequently increases the size of the dive profile to fill the area of the panel efficiently.
*Water temperature* is displayed with its own blue line with temperature values
placed adjacent to significant changes.
The dive profile can include graphs of the *partial pressures*
of O2, N2, and He during the dive (see figure above) as well as a calculated and dive computer
reported deco ceilings (only visible for deep, long, or repetitive dives).
Partial pressures of oxygen are indicated in green, those of nitrogen in black,
and those of helium in dark red. These
partial pressure graphs are shown below the profile data.
[icon="images/icons/O2.jpg"]
[NOTE]
Clicking this button allows display of the partial pressure of *oxygen* during the
dive. This is depicted below the dive depth and water temperature graphs.
[icon="images/icons/N2.jpg"]
[NOTE]
Clicking this button allows display of the partial pressure of *nitrogen* during the dive.
[icon="images/icons/He.jpg"]
[NOTE]
Clicking this button allows display of the partial pressure of *helium* during the dive.
This is only of importance to divers using Trimix, Helitrox or similar breathing gasses.
The *air consumption* graph displays the tank pressure and its change during the
dive. The air consumption takes depth into account so that even when manually
entering the start and end pressures the graph is not a straight line.
Similarly to the depth graph the slope of the tank pressure gives the user information
about the
momentary SAC rate (Surface Air Consumption) when using an air integrated dive computer.
Here the colour
coding is not relative to some absolute values but relative to the average
normalised air consumption during the dive. So areas that are red or orange
indicate
times of increased normalized air consumption while dark green reflects times
when the diver was using less gas than average.
[icon="images/icons/Heartbutton.png"]
[NOTE]
Clicking on the heart rate button will allow the display of heart rate information
during the dive if the dive computer was attached to a heart rate sensor.
It is possible to *zoom* into the profile graph. This is done either by using
the scroll wheel / scroll gesture of your mouse or trackpad. By default
_Subsurface_ always shows a profile area large enough for at least 30 minutes
and 30m
(100ft) – this way short or shallow dives are intuitively recognizable;
something
that free divers clearly won’t care about.
image::images/MeasuringBar.png["FIGURE: Measuring Bar",align="center"]
[icon="images/icons/ruler.jpg"]
[NOTE]
Measurements of *depth or time differences* can be achieved by using the
*ruler button* on the left of the dive profile panel.
The measurement is done by dragging the red dots to the two points
on the dive profile that the user wishes to measure. Information is then given
in the horizontal white area underneath the
two red dots.
[icon="images/icons/ShowPhotos.png"]
[NOTE]
Photographs that have been added to a dive can be shown on the profile
by selecting
the *Show-photo* button. The position of a photo on the profile
indicates the exact time when this photo was taken. If this button is not active,
the photos are hidden.
The profile can also include the dive computer reported *ceiling* (more
precisely, the deepest deco stop that the dive computer calculated for each
particular moment in time) as a red overlay on the dive profile. Ascent ceilings
arise when a direct ascent to the surface increases
the risk of a diver suffering from decompression sickness (DCS) and it is necessary
to either ascend
slower or to perform decompression stop(s) before ascending to the surface. Not
all dive computers record this information and make it available for download;
for example all of the Suunto dive computers fail to make this very useful data
available to divelog software. _Subsurface_ also calculates ceilings independently,
shown as a green overlay on the dive profile.
Because of the differences in algorithms used
and amount of data available (and other factors taken into consideration at the time
of the calculation) it is unlikely that ceilings from dive computers and from _Subsurface_
are the same, even if the same algorithm and _gradient factors_ (see below) are used.
It is also quite common that _Subsurface_ calculates a ceiling for
non-decompression dives when the dive computer stayed in non-deco mode during
the whole dive (represented by the [green]#dark green# section in the profile
at the beginning of this section). This is caused by the fact that
_Subsurface’s_
calculations describe the deco obligation at each moment during a dive,
while dive computers usually take the upcoming ascent into account. During the
ascent some excess nitrogen (and possibly helium) are already breathed off so
even
though the diver technically encountered a ceiling at depth, the dive still does
not require an explicit deco stop. This feature allows dive computers to offer
longer non-stop bottom times.
[icon="images/icons/cceiling.jpg"]
[NOTE]
If the dive computer itself calculates a ceiling and makes it available to
_Subsurface_ during upload of dives, this can be
shown as a red area by checking *Dive computer reported ceiling* button on the Profile Panel.
[icon="images/icons/ceiling1.jpg"]
[NOTE]
If the *Calculated ceiling* button on the Profile Panel is clicked, then a ceiling,
calculated by _Subsurface_, is shown in green if it exists for
a particular dive (*A* in figure below). This setting can be modified in two ways:
[icon="images/icons/ceiling2.jpg"]
[NOTE]
If, in addition, the *show all tissues* button on the Profile Panel is clicked, the ceiling is shown for the tissue
compartments following the Bühlmann model (*B* in figure below).
[icon="images/icons/ceiling3.jpg"]
[NOTE]
If, in addition, the *3m increments* button on the Profile Panel is clicked, then the ceiling is indicated in 3 m increments
(*C* in figure below).
image::images/Ceilings2.jpg["Figure: Ceiling with 3m resolution",align="center"]
[icon="images/icons/ShowCylindersButton.jpg"]
[NOTE]
By selecting this icon, the different cylinders used during a dive can be represented as a coloured bar at the bottom
of the *Dive Profile*. In general oxygen is represented by a green bar, nitrogen with a yellow bar and helium with a
red bar. The image below shows a dive which first uses a trimix cylinder (red and green), followed by a switch to a nitrox cylinder
(yellow and green) after 23 minutes. Cylinders with air are shown as a light blue bar.
image::images/ShowCylinders_f20.jpg["Figure: Cylinder use graph",align="center"]
[icon="images/tissues.jpg"]
[NOTE]
Display inert gas tissue pressures relative to ambient inert gas pressure (horizontal grey line).
Tissue pressures are calculated using the Bühlmann ZH-L16 algorithm and are displayed as lines ranging from
green (faster tissues) to blue (slower tissues).
The black line, graphed above the ambient pressure, is the maximum allowable tissue supersaturation (pressure limit) derived
from the gradient factors specified in the *Preferences*. For
divers involved in planned decompression diving, efficient rates of offgasing are obtained with tissue pressures
between the ambient inert gas pressure (grey line) and the pressure limit (black line). This display is a representation
of the tissue pressures during the whole dive. In contast, the xref:S_gas_pressure_graph[Gas Pressure Graph] in the *Information Box* on the *Dive Profile*
is an instantaneous reflection of tissue pressures at the moment in time reflected by the position of the cursor on the dive profile.
image::images/tissuesGraph.jpg["Figure: Inert gas tissue pressure graph",align="center"]
Gradient Factor settings strongly affect the calculated ceilings and their depths.
For more information about Gradient factors, see the section on xref:S_GradientFactors[Gradient Factor Preference settings]. The
currently used gradient factors (e.g. GF 35/75) are shown above the depth profile if the appropriate toolbar buttons are activated.
*N.B.:* The indicated gradient factors are NOT the gradient factors in use by the dive computer,
but those used by _Subsurface_ to calculate deco obligations
during the dive. For more information external to this manual see:
** http://www.tek-dive.com/portal/upload/M-Values.pdf[Understanding M-values by Erik Baker, _Immersed_ Vol. 3, No. 3.]
** link:http://www.rebreatherworld.com/general-and-new-to-rebreather-articles/5037-gradient-factors-for-dummies.html[Gradient factors for dummies, by Kevin Watts]
=== The Dive Profile context menu
The context menu for the Dive Profile is accessed by right-clicking while the
mouse cursor is over the Dive Profile panel. The menu allows the creation of
Bookmarks or Gas Change Event markers or manual CCR set-point changes other than the ones that might have been
imported from a Dive Computer. Markers are placed against the depth profile line
and with the time of the event set by where the mouse cursor was when the right
mouse button was initially clicked to bring up the menu. Gas Change events
involve a selection of which gas is being switched to, the list of choices being based on
the available gases defined in the Equipment Tab. Set-point change
events open a dialog allowing to choose the next set-point value. As
in the planner, a set-point value of zero indicates the diver is
breathing from an open circuit system while any non-zero value
indicates the use of a closed circuit rebreather (CCR).
By right-clicking while over
an existing marker a menu appears, adding options to allow deletion of the
marker or to allow all markers of that type to be hidden. Hidden events can be
restored to view by selecting Unhide all events from the context menu.
=== The *Information Box*
The Information box displays a large range of information pertaining to the dive
profile. Normally the Information Box is located to the top left of the *Dive
Profile* panel. If the mouse points outside of the *Dive Profile* panel, then
only the top line of the Information Box is visible (see left-hand part of
figure (*A*) below). The Information Box can be moved around in the *Dive Profile*
panel by click-dragging it with the mouse so that it is not obstructing
important detail. The position of the Information Box is saved and used again
during subsequent dive analyses.
image::images/InfoBox2.jpg["Figure: Information Box",align="center"]
The moment the mouse points inside the *Dive Profile* panel, the information box expands and
shows many data items. In this situation, the data reflect the time point along
the dive profile indicated by the mouse cursor (see right-hand part of figure (*B*) above
where the Information Box reflects the situation at the position of the cursor
[arrow] in that image). Therefore, moving the cursor in the horizontal
direction allows the Information Box to show information for any point along the
dive profile.
In this mode, the Information Box gives extensive statistics about depth, gas
and ceiling characteristics of the particular dive. These include: Time period
into the dive (indicated by a @), depth, cylinder pressure (P), temperature,
ascent/descent rate, surface air consumption (SAC), oxygen partial pressure,
maximum operating depth, equivalent air depth (EAD), equivalent narcotic depth
(END), equivalent air density depth (EADD), decompression requirements at that
instant in time (Deco), time to surface (TTS), the calculated ceiling, as well
as the calculated ceiling for several Bühlmann tissue compartments.
The user has control over the display of several statistics, represented as four
buttons on the left of the profile panel. These are:
[icon="images/icons/MOD.jpg"]
[NOTE]
Clicking this button causes the Information Box to display the *Maximum Operating Depth
(MOD)* of the dive, given the
gas mixture used. MOD is dependent on the oxygen concentration in the breathing gas.
For air (21% oxygen) it is around 57 m. Below the MOD there is a markedly increased
risk of exposure to the dangers associated with oxygen toxicity.
[icon="images/icons/NDL.jpg"]
[NOTE]
Clicking this button causes the Information Box to display the *No-deco Limit (NDL)* or the
*Total Time to Surface (TTS)*. NDL is the time duration that a diver can continue with a
dive, given the present depth, that does not require decompression (that is, before an
ascent ceiling appears). Once one has exceeded the NDL and decompression is required (that
is, there is an ascent ceiling above the diver, then TTS gives the number of minutes
required before the diver can surface. TTS includes ascent time as well as decompression
time.
[icon="images/icons/SAC.jpg"]
[NOTE]
Clicking this button causes the Information Box to display the *Surface Air Consumption (SAC)*.
SAC is an indication of the surface-normalised respiration rate of a diver. The value of SAC
is less than the real
respiration rate because a diver at 10m uses breathing gas at a rate roughly double that of
the equivalent rate at the surface. SAC gives an indication of breathing gas consumption rate
independent of the depth of the dive so that the respiratory rates of different dives
can be compared. The units for SAC is litres/min or cub ft/min.
[icon="images/icons/EAD.jpg"]
[NOTE]
Clicking this button displays the *Equivalent Air Depth (EAD)* for
nitrox dives as well as the *Equivalent
Narcotic Depth (END)* for trimix dives. These are numbers of
importance to divers who use breathing gases other than air. Their
values are dependent on the composition of the breathing gas. The EAD
is the depth of a hypothetical air dive that has the same partial
pressure of nitrogen as the current depth of the nitrox dive at
hand. A nitrox dive leads to the same decompression obligation as an
air dive to the depth equalling the EAD. The END is the depth of a
hypothetical air dive that has the same sum of partial pressures of
the narcotic gases nitrogen and oxygen as the current trimix dive. A
trimix diver can expect the same narcotic effect as a diver breathing
air diving at a depth equalling the END.
Figure (*B*) above shows an information box with a nearly complete set of data.
[[S_gas_pressure_graph]]
==== The Gas Pressure Bar Graph
On the left of the *Information Box* is a vertical bar graph indicating the
pressures of the nitrogen (and other inert gases, e.g. helium, if applicable) that the diver
was inhaling _at a particular instant during the dive_, indicated by the position
of the cursor on the *Dive Profile*. The drawing on the left below indicates the
meaning of the different parts of the Gas Pressure Bar Graph.
image::images/GasPressureBarGraph.jpg["FIGURE:Gas Pressure bar Graph",align="center"]
- The light green area indicates the total gas, with the top margin of the light green
area indicating the total gas pressure inhaled by the diver and measured from the bottom
of the graph to the top of the light green area. This pressure has a _relative_ value in the graph
and does not indicate absolute pressure.
- The horizontal black line underneath the light green margin indicates the equilibrium pressure
of the inert gases inhaled by the diver, usually nitrogen. In
the case of trimix, it is the pressures of nitrogen and helium combined. In this example,
the user is diving with EAN32, so the inert gas pressure is 68% of the distance from the
bottom of the graph to the total gas pressure value.
- The dark green area at the bottom of the graph represents the pressures of inert gas in each
of the 16 tissue compartments, following the Bühlmann algorithm, the fast tissues being on the
left hand side.
- The top black horizontal line indicates the gradient factor that applies to the depth of
the diver at the particular point on the *Dive Profile*. The appropriate gradient factor is an
interpolation between the FGLow and GFHigh values specified in the Graph tab of the *Preferences
Panel* of *Subsurface*.
- The bottom margin of the red area in the graph indicates the Bühlman-derived M-value, that is the
pressure value of inert gases at which bubble formation is expected to be severe, resulting
in decompression sickness.
These five values are indicated on the left in the graph above. The way the Gas Pressure Bar Graph changes
during a dive is indicated on the right hand side of the above figure for a diver using EAN32.
- Graph *A* indicates the situation at the start of a dive with diver at the surface. The pressures in all
the tissue compartments are still at the equilibrium pressure because no diving has taken place.
- Graph *B* indicates the situation after a descent to 30 meters. Few of the tissue compartments have had
time to respond to the descent, their gas pressures being far below the equilibrium gas pressure.
- Graph *C* represents the pressures after 30 minutes at 30 m. The fast compartments have attained
equilibrium (i.e. they have reached the hight of the black line indicating the equilibrium pressure). The
slower compartments (towards the right) have not reached equilibrium and are in the process of slowly
increasing in pressure.
- Graph *D* shows the pressures after ascent to a depth of 4.5 meters. Since, during ascent, the total
inhaled gas pressure has decreased strongly from 4 bar to 1.45 bar, the pressures in the different tissue
compartments now exceed that of the total gas pressure and approaches the gradient factor value (i.e.
the top black horizontal line). Further ascent will result in exceeding the gradient
factor value (GFHigh), endangering the diver.
- Graph *E* indicates the situation after remaining at 4.5 meters for 10 minutes. The fast compartments
have decreased in pressure. As expected, the pressures in the slow compartments have not changed much.
The pressures in the fast compartments do not approach the GFHigh value any more and the diver is safer
than in the situation indicated in graph *D*.
== Organising the logbook (Manipulating groups of dives)
=== The Dive List context menu
Many actions within _Subsurface_ are dependent on a context menu used
mostly to manipulate groups of dives. The context menu is found by selecting
a dive or a group of dives and then right-clicking.
image::images/ContextMenu.jpg["Figure: Context Menu",align="center"]
The context menu is used in many manipulations described below.
==== Customising the information showed in the *Dive List* panel
image::images/DiveListOptions.jpg["Example: Dive list info options",align="center"]
The default information in the *Dive List* includes, for each dive, Dive_number, Date, Rating, Dive_depth,
Dive_duration and Dive_location. This information can be controlled and changed by right-clicking on the
header bar of the *Dive List*. For instance, a right-click on the 'Date' header brings up a list of items
that can be shown in the dive list (see above). Select an item to be shown in the *Dive List* or to be
deleted from the dive list, and the list is immediately updated accordingly. Preferences for information
shown in the *Dive List* is saved and used when _Subsurface_ is re-opened.
==== Selecting dives from a particular dive site
Many divers have long dive lists and it may be difficult to locate all the dives at a particular site.
By pressing _Ctl-F_ on the keyboard, a text box is opened at the top left hand of the *Dive List*.
Type the name of a dive site in this text box and the *Dive List* is immediately filtered to
show only the dives for that site.
[[S_Renumber]]
=== Renumbering the dives
Dives are normally numbered incrementally from non-recent dives (low sequence
numbers) to recent dives (having the highest sequence numbers). The numbering
of the dives is not always consistent. For instance, when non-recent dives are
added to the dive list the numbering does not automatically follow on because
of the dives that are more recent in date/time than the newly-added dive with
an older date/time. Therefore, one may sometimes need to renumber the dives.
This is performed by selecting (from the Main Menu) _Log -> Renumber_. Users are
given a choice with respect to the lowest sequence number to be used.
Completing this operation results in new sequence numbers (based on date/time)
for the dives in the *Dive List* panel.
[[S_Group]]
=== Grouping dives into trips and manipulating trips
For regular divers, the dive list can rapidly become very long. _Subsurface_
can group dives into _trips_. It performs this by grouping dives that have
date/times that are not separated in time by more than two days, thus creating
a single heading for each diving trip represented in the dive log. Below is an
ungrouped dive list (*A*, on the left) as well as the corresponding grouped dive
list comprising five dive trips (*B*, on the right):
image::images/Group2.jpg["Figure: Grouping dives",align="center"]
Grouping into trips allows a rapid way of accessing individual dives without
having to scan a long lists of dives. In order to group the dives in a dive list,
(from the Main Menu) users must select _Log -> Autogroup_. The *Dive List* panel
now shows only the titles for the trips.
==== Editing the title and associated information for a particular trip
Normally, in the dive list, minimal information is included in the trip title.
More information about a trip can be added by selecting its trip title from
the *Dive List*. This shows a *Trip Notes* tab in the *Dive Notes* panel. Here
users can add or edit information about the date/time, the trip location and any
other general comments about the trip as a whole (e.g. the dive company that was
dived with, the general weather and surface conditions during the trip, etc.).
After entering this
information, users should select *Save* from the buttons at the top right
of the *Trip Notes*
tab. The trip title in the *Dive List* panel should now reflect some of the
edited information.
==== Viewing the dives during a particular trip
Once the dives have been grouped into trips, users can expand one or more
trips by clicking the arrow-head on the left of each trip title. This expands
the selected trip, revealing the individual dives performed during the trip.
==== Collapsing or expanding dive information for different trips
If a user right-clicks after selecting a particular trip in the dive list, the
resulting context menu allows several possibilities to expand or collapse dives
within trips. This includes expanding all trips, collapsing all trips and
collapsing all trips except the selected one.
==== Merging dives from more than one trip into a single trip
By right-clicking on a selected trip title in the *Dive List* panel, a
context menu shows up that allows the merging of trips by either merging of the selected trip
with the trip below or with the trip above.
==== Splitting a single trip into more than one trip
If a trip includes five dives, the user can split this trip into two trips (trip 1:
top 3 dives; trip 2: bottom 2 dives) by selecting and right-clicking the top
three dives. The resulting context menu allows the user to create a new trip by
choosing the option *Create new trip above*. The top three dives are then
grouped
into a separate trip. The figures below shows the selection and context menu
on the left (A) and
the completed action on the right (B):
image::images/SplitDive3a.jpg["FIGURE: Split a trip into 2 trips",align="center"]
=== Manipulating single dives
==== Delete a dive from the dive log
Dives can be permanently deleted from the dive log by selecting and
right-clicking them to bring up the context menu, and then selecting *Delete
dive(s)*. Typically this would apply to a case where a user wishes to delete
workshop
calibration dives of the dive computer or dives of extremely short duration.
==== Unlink a dive from a trip
Users can unlink dives from the trip to which they belong. In order to do this,
select and right-click
the relevant dives to bring up the context menu. Then select the option *Remove dive(s)
from trip*. The dive(s) now appear immediately above the trip to
which they belonged.
==== Add a dive to the trip immediately above
Selected dives can be moved from the trip to which they belong and placed within
the trip immediately above the currently active trip. To do this, select
and right-click
the dive(s) to bring up the context menu, and then select *Add dive(s) to trip
immediately above*.
==== Shift the start time of dive(s)
Sometimes it is necessary to adjust the start time of a dive. This may apply to
situations where dives are performed in different time zones or when the dive
computer has an erroneous time. In order to do this, user must select and right-click
the dive(s) to be
adjusted. This action brings up the context menu on which the *Shift times*
option should be selected. User must then specify the
time
(in hours and minutes) by which the dives should be adjusted and click on the
option indicating whether the time adjustment should be forwards or backwards.
==== Merge dives into a single dive
Sometimes a dive is briefly interrupted, e.g. if a diver returns to the surface
for a few minutes, resulting in two or more dives being recorded by the dive
computer and appearing as different dives in the *Dive List* panel. Users can
merge these dives onto a single dive by selecting the appropriate dives,
right-clicking them to bring up the context menu and then selecting *Merge selected
dives*. It may be necessary to edit the dive information in the *Dive Notes*
panel to reflect events or conditions that apply to the merged dive. The figure
below shows the depth profile of two such dives that were merged:
image::images/MergedDive.png["Example: Merged dive",align="center"]
[[S_Filter]]
=== Filtering the dive list
The dives in the *Dive List* panel can be filtered, that is, one can select only some
of the dives based on their attributes, e.g. dive tags, dive site, dive master, buddy or protective
clothing. For instance, filtering allows one to list the deep dives at a particular
dive site, or otherwise the cave dives with a particular buddy.
To open the filter, select _Log -> Filter divelist_ from the main menu. This opens the
_Filter Panel_ at the top of the _Subsurface_ window. Three icons are located at the top
right hand of the filter panel. The _Filter Panel_ can be reset
(i.e. all current filters cleared) by selecting the *+*. The _Filter Panel_ may also be
minimised by selecting the middle icon. When minimised, only these three icons are shown.
The panel can be maximised by clicking the icon that minimised the panel. The filter may also be
reset and closed by selecting the button with the flag.
An example of the _Filter Panel_ is shown in the figure below.
image::images/Filterpanel.jpg["Figure: Filter panel",align="center"]
Four filter criteria may be used to filter the dive list: dive tags, person (buddy / dive master), dive site
and dive suit, each of which is represented by a check list with check boxes. Above
each check list is a second-level filter tool, allowing the listing of only some of
the attributes within that check list. For instance, typing "_ca_" in the filter
textbox above the tags check list results in the tags check list being reduced
to "_cave_" and "_cavern_". Filtering of the check list enables the rapid finding
of search terms for filtering the dive list.
To activate filtering of the dive list, the check box of at least one item in one of
the four check lists needs to be checked. The dive list is then shortened to include
only the dives that pertain to the selection criteria specified in the check lists.
The four check lists work as a filter with _AND_ operators, Subsurface
filters therefore for _cave_ as a tag AND _Joe Smith_ as a buddy; but the
filters within a category are inclusive - filtering for _cave_ and _boat_
shows those dives that have either one or both of these tags.
[[S_ExportLog]]
== Exporting the dive log or parts of the dive log
The export function can be reached by selecting _File -> Export_, which brings up
the Export dialog. This dialog always gives two options: save ALL dives, or save only
the dives selected in *Dive List* panel of _Subsurface_. Click the appropriate
radio button (see images below).
image::images/Export_f20.jpg["Figure: Export dialog",align="center"]
A dive log or part of it can be saved in three formats:
* _Subsurface XML_ format. This is the native format used by _Subsurface_.
* Universal Dive Data Format (_UDDF_). Refer to _http://uddf.org_ for more information.
UDDF is a generic format that enables communication among many dive computers
and computer programs.
* _Divelogs.de_, an Internet-based dive log repository. In order to upload to _Divelogs.de_,
one needs a user-ID as well as a password for _Divelogs.de_. Log into _http://en.divelogs.de_
and subscribe to this service in order to upload dive log data from _Subsurface_.
* _DiveShare_ is also a dive log repostory on the Internet focusing on the recreational
dives. In order to upload dives one has to provide a used ID, so registration with
_http://scubadiveshare.com_ is required.
* _CSV dive details_, that includes the most critical information of the dive
profile. Included information of a dive is: dive number, date, time, buddy,
duration, depth, temperature and pressure: in short, most of the information
that recreational divers enter into handwritten log books.
* _CSV dive profile_, that includes a large amount of detail for each dive, including
the depth profile, temperature and pressure information of each dive.
* _HTML_ format, in which the dive(s) are stored in HTML files, readable
with an Internet browser. Most modern web browsers are supported, but JavaScript
must be enabled. This HTML file is not intended to be edited
by the users.
The HTML dive log contains most of the information and also contains a search
option to search the dive log. HTML export is specified on the second tab of the
Export dialog (image *B* above). A typical use of this option is to export all one's
dives to a smartphone or a tablet where it would serve as a very portable record
of dives useful for dive companies that wish to verify the dive history of a diver.
This does away with the need to carry one's original logbook with one
when doing dives with dive companies.
* _Worldmap_ format, an HTML file with a world map upon which each dive and
some information about it are indicated. This map is not editable. However, if one selects any
of the dive sites on the map, a summary of the dive is available in text, as shown
in the image below.
image::images/mapview_f20.jpg["Figure: HTML Map export view",align="center"]
* _Image depths_, which creates a text file that contains the file names of all
photos or images attached
to any of the selected dives in the _Dive List_, together with the depth under water where
of each of those photos were taken.
* _General Settings_, under the HTML tab, provides the following options:
** Subsurface Numbers: if this option is checked, the dive(s) are exported with the
numbers associated with them in Subsurface, Otherwise the dive(s) will be numbered
starting from 1.
** Export Yearly Statistics: if this option is checked, a yearly statistics table will
be attached with the HTML exports.
** Export List only: a list of dives will only be exported and the detailed dive
information will not be available.
* Under _Style Options_ some style-related options are available like font
size and theme.
Export to other formats can be achieved through third party facilities, for
instance _www.divelogs.de_.
[[S_Cloud_access]]
== Keeping a _Subsurface_ dive log in the Cloud
For each diver, dive log information is highly important. Not only is it a record
of diving activities for one's own pleasure, but it is important information required
for admission to further training courses or (sometimes) even diving sites. The
security of the dive log is therefore critical. In order to have a dive log that is
resistant to failure of a home computer hard drive, loss or theft of equipment, the
Cloud is an obvious solution. This also has the added benefit that one can access one's dive
log from anywhere in the world without having to carry it with oneself. For this
reason, facilities such as _divelogs.de_ and _Diving Log_ offer facilities to store
dive log information on the Internet. Although _Subsurface_ does not offer integrated
Cloud storage of dive logs, it is simple to achieve this using several of the
existing facilities on the Internet.
For instance
http://www.dropbox.com/[_Dropbox_]
offers a free application that allows
files on the Dropbox servers to be seen as a local folder on one's desktop computer.
image::images/Cloud.jpg["FIGURE: Dropbox folder",align="center"]
The _Dropbox_ program creates a copy of the _Dropbox_ Internet Cloud content on one's
desktop computer. When the computer is connected to the Internet, the Internet
content is automatically updated. Therefore both the _Open_ and _Save_ of dive logs are done
using the local copy of the dive log in the local _Dropbox_ folder, so there's no need
for a direct internet connection. If the local copy is modified, e.g. by adding a dive,
the remote copy in the _Dropbox_ server in the Cloud will be automatically updated whenever
Internet access is available.
In this way a dive log in
one's _Dropbox_ folder can be accessed seamlessly from the Internet and can
be accessed from any place with Internet access. Currently there are no costs
involved for this service. Dropbox (Windows, Mac
and Linux) can be installed by accessing the
http://www.dropbox.com/install[_Install Page on the Dropbox website_]
. Alternatively one can use _Dropbox_ as a mechanism to backup one's dive log. To
Store a dive log in the Cloud, select _File -> Save as_ from the _Subsurface_ main menu,
navigate to the _Dropbox_ folder and select the _Save_ button. To access the dive log
in the Cloud, select _File -> Open Logbook_ from the _Subsurface_
main menu and navigate to the dive log file in the _Dropbox_ folder and select the
_Open_ button.
Several paid services exist on the Internet (e.g. Google, Amazon) where the same
process could be used for the Cloud-based storage of dive logs.
[[S_PrintDivelog]]
== Printing a dive log
_Subsurface_ provides a simple interface to print a whole dive log or only a
few selected dives, including dive profiles and other contextual information.
Before printing, two decisions are required:
- Should the whole dive log be printed or only part of it? If only part of the
dive log is required, then the user must select the required dives from the *Dive List* panel.
- What gas partial pressure information is required on the dive profile? Users should select
the appropriate toggle-buttons on the button bar to the left of the Dive Profile panel.
Now the print options should be selected to match the user's needs. To do this, user should select _File -> Print_ from
the Main menu. The following dialogue appears (see the image on the left [A],
below).
image::images/PrintDiveLog.jpg["FIGURE: Print dialogue",align="center"]
Under _Print type_ users need to select one of three options:
- Print the complete Dive List: to do this, _Table Print_ should be selected.
- Print the selected dives (dive profiles and all other information) at 6
dives per printed page: to do this, users should select _6 dives per page_.
- Print the selected dives (dive profiles and all other information) at 2
dives per printed page: to do this, users should select _2 dives per page_.
- Print the selected dives (dive profiles and all other information) at 1
dive per printed page: to do this, users should select _1 dive per page_.
Under _Print options_ users need to select:
- Printing only the dives that have been selected from the dive list prior to
activating the print dialogue, achieved by checking the box _Print only
selected dives_.
- Printing in colour, achieved by checking the box with _Print in colour_.
The _Ordering_ affects the layout of the page (or part of it) for each dive.
The dive profile could be printed at the top of each dive, with the textual
information underneath, or it could be printed with the textual information at
the top with the dive profile underneath. Users should select the appropriate option in the
print dialogue. See the image below which has a layout with
text below the dive profile.
Users can _Preview_ the printed page by selecting the _Preview_ button on the
dialogue. After preview, changes to the options in the print dialogue can be
made, resulting in a layout that fits personal taste.
Next, select the _Print_ button in the dialogue. This activates the regular print
dialogue used by the user operating system (image [*B*] in the middle, above),
allowing them to choose a printer and to set its properties (image [*C*] on the right,
above).
It is important to set the print resolution of the printer to an appropriate value by
changing
the printer properties. Finally, one can print the dives. Below is a (rather small)
example of
the output for one particular page.
image::images/Printpreview.jpg["FIGURE: Print preview page",align="center"]
[[S_Preferences]]
== Setting user _Preferences_ for _Subsurface_
There are several settings within _Subsurface_ that the user can specify. These
are found when selecting _File -> Preferences_. The settings are performed in
five groups: *Defaults*, *Units*, *Graph*, *Language* and *Network*. All five sections
operate on the same principles: the user must specify the settings that are to be changed, then
these changes are saved using the *Apply* button. After applying all the new settings users can then
leave the settings panel by selecting *OK*.
=== Defaults
There are several settings in the *Defaults* panel:
image::images/Pref1_f20.jpg["FIGURE: Preferences defaults page",align="center"]
** *Lists and tables*: Here one can specify the font type and font size of the
*Dive Table* panel. By decreasing the font size of the *Dive Table*, users can see more dives on a screen.
** *Dives*: For the _Default Dive File_ one need to specify the directory and
file name of one's
electronic dive log book. This is a file with filename extension .xml. When
launched, _Subsurface_ will automatically load the specified dive log book.
** *Display invalid*: Dives can be marked as invalid (when a user wishes to hide
dives that he/she don't consider valid dives, e.g. pool dives, but still want to
keep them in the dive log). This controls whether those dives are displayed in
the dive list.
** *Default cylinder*: Here users can specify the default cylinder listed in
the *Equipment* tab of the *Dive Notes* panel.
** *Animations*: Some actions in showing the dive profile are performed using
animations. For instance, the axis values for depth and time change from dive to
dive. When viewing a different dive, these changes in axis characteristics do not
happen instantaneously, but are animated. The _Speed_ of animations can be controlled
by setting this slider
with faster animation speed to the left, with a 0 value representing no animation
at all.
** *Subsurface web service*: When one subscribes to the <<S_Companion,Subsurface web service>>, a very
long and hard-to-remember userID is issued. This is the place to save that userID. By
checking the option _Save User ID locally?_, one ensures that a local copy of that userID
is saved.
** *Clear all settings*: As indicated in the button below this heading, all settings are
cleared and set to default values.
=== Units
image::images/Pref2_f20.jpg["FIGURE: Preferences Units page",align="center"]
Here user can choose between metric and imperial units of depth, pressure,
volume, temperature and mass. By selecting the Metric or Imperial radio button
at the top, users can specify that all units are in the chosen measurement system.
Alternatively, if one selects the *Personalise* radio button, units can be selected
independently, with some units in the metric system and others in imperial.
=== Graph
[[S_CCR_options]]
image::images/Pref3_f20.jpg["FIGURE: Preferences Graph page",align="center"]
[[S_GradientFactors]]
This panel allows two type of selections:
* *Show*: Here users can specify the amount of information shown as part of
the dive profile:
** Thresholds: _Subsurface_ can display the nitrogen, oxygen and the helium partial pressures during
the dive. These are enabled using the toolbar on the left hand side of the *Dive Profile*
panel. For each of these graphs users can specify a threshold value on the right-hand side of the
Preferences panel. If any of the graphs go above this threshold level, the graph is
highlighted in red, indicating that the threshold has been exceeded.
** _Draw dive computer reported ceiling red_: This checkbox allows exactly what it says.
Not all dive computers report ceiling values. If the dive computer does report it, it may differ
from the ceilings calculated by _Subsurface_. This is because of the different algorithms and gradient factors available for calculating ceilings, as well as the dynamic way that a
dive computer can calculate ceilings during a dive.
** _Show unused cylinders in Equipment Tab_: This checkbox allows display of information about unused cylinders when viewing the *Equipment Tab*. Conversely, if this box is not checked, and any cylinders entered using the *Equipment Tab* are not used (e.g. there was no gas switch to such a cylinder), then these cylinders are omitted from that list.
** _Show average depth_: Activating this checkbox causes _Subsurface_ to draw a red line across
the dive profile, indicating the mean depth of the dive.
* *Misc*:
** Gradient Factors:* Here users can set the _gradient factors_ used while diving. GF_Low is
the gradient factor at depth and GF_High is used just below the surface.
At intermediate depths gradient factors between GF_Low and GF_High are used.
Gradient factors add conservatism to the nitrogen exposure during a dive, in a
similar way that many dive computers have a conservatism setting. The lower
the value of a gradient factor, the more conservative the calculations are with
respect to nitrogen loading and the deeper the ascent ceilings are. Gradient
factors of 20/60 are considered conservative and values of 60/90 are considered
harsh. Checking *GFLow at max depth* box causes GF_Low to be used at the
deepest depth of a dive. If this box is not checked, GF_Low is applied at
all depths deeper than the first deco stop. For more information see:
*** http://www.tek-dive.com/portal/upload/M-Values.pdf[Understanding M-values by Erik Baker, _Immersed_ Vol. 3, No. 3.]
*** link:http://www.rebreatherworld.com/general-and-new-to-rebreather-articles/5037-gradient-factors-for-dummies.html[Gradient factors for dummies, by Kevin Watts]
** _CCR: Show setpoints when viewing pO2:_ With this checkbox ativated, the pO~2~
graph on the dive profile has an overlay in red which inticates the CCR setpoint
values. See the section on xref:S_CCR_dives[Closed Circuit Rebreather dives].
** _CCR: Show individual O~2~ sensor values when viewing pO~2~:_ Show the pO~2~
values associated with each of the individual oxygen sensors of a CCR system.
See the section on xref:S_CCR_dives[Closed Circuit Rebreather dives].
* *Configuring dive planning using rebreather equipment:*
** _Default CCR setpoint for dive planning:_ Specify the O~2~ setpoint for a
CCR dive plan. This determines the pO~2~ that will be maintained
during a particular dive. This is the setpoint that is used at the start
of any CCR dive. Setpoint changes during the dive can be added via the
profile context menu.
** _pSCR O~2~ metabolism rate:_ For a semiclosed rebreather (pSCR) system, this is the
volume of oxygen used by a diver each minute. Set this value for pSCR dive planning
and decompression calculations.
** _pSCR ratio:_ For pSCR equipment the dump ratio is the ratio of gas released to the
environment to that of the gas recirculated to the diver. Set this value for a
pSCR dive plan.
=== Language
Choose a language that _Subsurface_ will use.
image::images/Pref4_f20.jpg["FIGURE: Preferences Language page",align="center"]
A checkbox allows one to use the _System Default_ language which in most cases
will be the correct setting; with this _Subsurface_ simply runs in the same
language / country settings as the underlying OS. If this is for some reason
undesirable users can uncheck this checkbox and pick a language / country
combination from the list of included localizations. The _Filter_ text box allows
one to list similar languages. For instance there are several system variants of English
or French. This particular preference requires a restart of _Subsurface_ to take
effect.
=== Network
This panel facilitates communication between _Subsurface_ and data sources on the Internet.
image::images/Pref5_f20.jpg["FIGURE: Preferences Network page",align="center"]
This is important, for instance, when _Subsurface_ needs to communicate with Internet
services such as the <<S_Companion,_Subsurface Companion app_>> or data export/import
from _Divelogs.de_. These Internet requirements are determined by one's type of
connection to the Internet and by the Internet Service Provider (ISP) used.
One's ISP should provide the appropriate information.
If a proxy server is used for Internet access, the appropriate information needs
to be provided here. The type of proxy needs to be selected from the dropdown list.
after which the IP address of the host and the appropriate port number should
be provided. If the proxy server uses authentication, the appropriate userID and
password also needs to be provided so that _Subsurface_ can automatically pass
through the proxy server to access the Internet.
[[S_DivePlanner]]
== The _Subsurface_ dive planner
Dive planning is an advanced feature of _Subsurface_, accessible by selecting
_Log -> Plan Dive_ from the main menu. It allows calculation of
nitrogen load during a dive by using the Bühlmann ZH-L16 algorithm with the addition
of gradient factors as implemented by Erik Baker.
****
[icon="images/icons/warning2.png"]
[WARNING]
The _Subsurface_ dive planner IS CURRENTLY EXPERIMENTAL
and assumes the user is already familiar with the _Subsurface_
user interface. It is explicitly used under the following conditions:
- The user is conversant with dive planning and has the necessary training to perform
dive planning.
- The user plans dives within his/her certification limits.
- Dive planning makes large assumptions about the characteristics of the _average person_
and cannot compensate for individual physiology or health or personal history or
life style characteristics.
- The safety of a dive plan depends heavily on the way in which the planner is used.
- The user is familiar with the user interface of _Subsurface_.
- A user who is not absolutely sure about any of the above requirements should not use
this feature.
****
=== The _Subsurface_ dive planner screen
Like the _Subsurface_ dive log, the planner screen is divided into several sections (see image below). The *setup*
parameters for a dive are entered into the several sections on the left hand side of the screen.
The setup is divided into several sections: Available Gases, Rates, Planning, Gas Options and Dive Notes.
At the top right hand is a green *design panel* upon which the profile of the dive can be
manipulated directly by dragging and clicking as explained below. This feature makes the
_Subsurface_ dive planner unique in ease of use.
At the bottom right is a text panel with a heading of _Dive Plan Details_. This is where the details of
the dive plan are provided in a way that can easily be copied to other software. This is also where
any warning messages about the dive plan are printed.
image::images/PlannerWindow1_f20.jpg["FIGURE: Dive planner startup window",align="center"]
=== Initiating dive planning
The dive planner comprises two parts: *constructing a dive plan* and *evaluating*
that dive plan. To perform dive planning, perform these steps:
- Clear the existing dive log by creating a new planning log. This is achieved by selecting
_File -> New logbook_ from the main menu. This way, dive plans are kept separate
from the existing dive log of completed dives.
- In the top left-hand area of the screen, ensure that the constant dive parameters are
appropriate. These are: Start date and time of the dive, Atmospheric Pressure and Altitude
above sea level of the dive site. The atmospheric pressure can also be entered as an altitude
in metres, assuming an atmospheric pressure of 1.013 bar.
- In the table labelled _Available Gases_, add the information of the cylinders to be used
as well as the gas composition within that cylinder. This is done in a similar way as for
<<S_CylinderData,providing cylinder data for dive logs>>. Choose the cylinder type by
double clicking the cylinder type and using the dropdown list, then specify the work
pressure of this cylinder. By leaving the oxygen concentration (O2%) filed empty,
the dive gas is assumed to be air. Otherwise enter the oxygen and/or helium
concentration in the boxes provided in this dialogue. Add additional cylinders by using the
"+" icon to the top righthand of the dialogue.
- The dialogue indicating _Dive Planner Points_ is usually not used at this stage of the dive
planning.
=== Managing nitrogen, oxygen and gas consumption
The planning is performed in three stages:
*a) Nitrogen management*: This is performed by specifying the rates for descent and ascent,
as well as the gradient factors (GFLow and GFHigh) under the headings _Rates_ and _Planning_
to the bottom left of the planning screen. Initially, the GFHigh and GFLow values in the _Preferences_
panel of _Subsurface_ is used. If these are changed within the planner (see _Gas Options_ within
the planner), the new values are
used without changing the original specifications in the _Preferences_. Gradient Factor settings strongly affect the calculated ceilings and their depths.
A very low GFLow value brings about decompression stops early on during the dive.
** For more information about Gradient factors, see the section on xref:S_GradientFactors[Gradient Factor Preference settings].
For more information external to this manual see:
*** link:http://www.tek-dive.com/portal/upload/M-Values.pdf[Understanding M-values by Erik Baker, _Immersed_ Vol. 3, No. 3.]
*** link:http://www.rebreatherworld.com/general-and-new-to-rebreather-articles/5037-gradient-factors-for-dummies.html[Gradient factors for dummies, by Kevin Watts]
*** link:http://www.amazon.com/Deco-Divers-Decompression-Theory-Physiology/dp/1905492073/ref=sr_1_1?s=books&ie=UTF8&qid=1403932320&sr=1-1&keywords=deco+for+divers[_Deco for Divers_, by Mark Powell (2008). Aquapress] Southend-on-Sea, UK. ISBN 10: 1-905492-07-3.
An excellent non-technical review.
** The ascent rate is critical for nitrogen off-gassing at the end of the dive and is specified
for several depth ranges, utilising the average (or mean) depth as a yardstick. The mean depth
of the dive plan is indicated on the dive profile in the green panel of the dive planner. Ascent rates
at deeper levels are often in the range of 8-12 m/min, while ascent rates near the surface are
often in the range of 4-9 m/min. The descent rate is also specified. If the option _Drop to first depth_
is activated, then the descent phase of the planned dive will be at the maximal descent rate specified
in the _Rates_ section of the dive setup.
*b) Oxygen management*: In the *Gas Options* part of the dive specification, the maximum partial
pressure for oxygen needs to be specified for the
bottom part of the dive (_bottom po2_) as well as for the decompression part of the dive (_deco po2_).
The most commonly
used values are 1.4 bar for the bottom part of the dive and 1.6 bar for any decompression
stages. Normally, a partial pressure of 1.6 bar is not exceeded. PO2 settings and the depth at which switching to a gas takes place can also be edited in the
_Available Gases_ dialog. Normally the planner decides on switching to a new gas when, during
ascent, the partial pressure of the new gas has decreased to 1.6 bar.
*c) Gas management*: One needs keep within the limits of the amount of gas contained in the dive
cylinder(s), allowing for an appropriate margin for safe return to the surface, possibly
sharing with a buddy. Under the _Gas Options_ heading, specify the best (but conservative) estimate
of your surface-equivalent air consumption (SAC, also termed RMV) in
litres/min (for the time being, only SI units are supported). Specify the SAC during the
bottom part of the dive (_bottom SAC_) as well as during the decompression or safety stops of the
dive (_deco SAC_). Values of 20-30 l/min are common. For good gas management, a thumbsuck guess
is not sufficient and one needs to
monitor one's gas consumption on a regular basis, dependent on different dive conditions and/or equipment.
The planner will calculate the total volume of gas used during the dive and will issue a warning
if one exceeds the total amount of gas available. Good practice demands that one does not dive to
the limit of the gas supply but that an appropriate reserve is kept for unforeseen circumstances.
For technical diving, this reserve can be up to 66% of the total available gas.
Now (at last) one can start the detailed time-depth planning of the dive. _Subsurface_ offers a unique
graphical interface for performing this part of the planning. The mechanics of doing this is
similar to hand-entering a dive profile in the dive log part of _Subsurface_. Upon activating the
planner, a default dive of depth 15 m for 40 min is offered in the green design surface to the top
right hand of the screen. The white dots (waypoints) on the
profile can be dragged with a mouse. Create more waypoints by double-clicking on the profile
line and ensuring that the profile reflects the intended dive. Drag the waypoints to represent
the depth and duration of the dive.
If any of the management limits (for nitrogen, oxygen or gas) is exceeded, the surface
above the dive profile changes from BLUE to RED.
Each waypoint on the dive profile creates a _Dive Planner Point_ in the table on the
left of the dive planner panel. Ensure that the _Used Gas_ value in each row
of that table corresponds to one of the gas mixtures specified in the table with
_Available Gases_ immediately above the Dive Planner Points. Add new waypoints
until the main features of the dive have been completed, e.g. the
bottom time segment and deep stops (if these are implemented). Leave the remaining
waypoints on the ascent to _Subsurface_. In most cases _Subsurface_
computes additional way points in order to fulfil decompression requirements for that
dive. A waypoint can be moved by selecting that waypoint and by using the arrow keys.
The waypoints listed in the _Dive Planner Points_ dialogue can be edited by hand in
order to obtain a precise presentation of the dive plan. In fact, one can create the
whole dive profile by editing the _Dive Planner Points_ dialog.
Indicate any changes in gas cylinder used by indicating gas changes as explained
in the section <<S_CreateProfile,hand-creating a dive profile>>. These changes should
reflect the cylinders and gas compositions defined in the table with _Available Gases_.
If two or more gases are used, automatic gas switches will be suggested during the ascent to
the surface. However, these changes can be deleted by right-clicking the gas change and by
manually creating a gas change by right-clicking on the appropriate
waypoint.
A non-zero value in the "CC set point" column of the table of dive planner points
indicates a valid setpoint for oxygen partial pressure and that the segment
is dived using a closed circuit rebreather (CCR). If the last manually entered
segment is a CCR segment, the decompression phase is computed assuming the diver
uses a CCR with the specified set-point. If the last segment (however
short) is on open circuit (OC, indicated by a zero set-point) the
decompression is computed in OC mode. The planner only considers gas
changes in OC mode.
Below is an example of a dive plan to 45m using EAN26, followed by an ascent using EAN50
and using the settings as described above.
image::images/DivePlanner2_f20.jpg["FIGURE: Planning a dive: setup",align="center"]
Once the above has been completed, one can save it by clicking the _Save_ button
towards the bottom left of the green design panel. The saved dive plan will appear
in the *Dive List* panel of _Subsurface_.
=== The dive plan details
On the bottom right of the dive planner, under _Dive Plan Details_, the exact details
of the dive plan are provided. These details may be modified by checking any of the
options under the _Dive Notes_ section of the dive planner, immediately to the left
of the _Dive Plan Details_. If a _Verbatim diveplan_
is requested, a detailed sentence-level explanation of the dive plan is given. If any
of the management specifications have been exceeded during the planning, a warning
message is printed underneath the dive plan information.
If the option _Display segment duration_ is checked, then the duration of each depth
level is indicated in the _Dive Plan Details_. This duration INCLUDES the transition
time to get to that level. However, if the _Display transition in deco_ option is checked,
the transitions are shown separately from the segment durations at a particular level.
=== Planning rebreather dives
To plan a dive using a passive semi-closed rebreather (pSCR), select "pSCR" rather than
"Open circuit" in the Planning tab. This takes the oxygen drop in the rebreather into account.
The parameters of the pSCR can be set in the preferences in the Graph tab. A warning apears
in the dive plan details, if the pO~2~ drops below what is considered a save value. For pSCR dives,
the gas consumption calculation takes into account the pSCR ratio (default 10:1).
To plan a dive using a closed circuit rebreather (CCR), select the "CCR" option in the PLannig tab.
This makes all user entered segments use the default setpoint value (configured in the Preferences
in the Graph tab). The gases from the gas list are considered to be diluent gases (the oxygen tank is
implicitely assumed to be present).
Then, individual setpoints can be set for dive segments in the "Dive planner points" table. A zero setpoint
means the diver bails out to open circuit mode for that segment. The decompression is always calculated
with the setpoint of the last manually entered segment. So, to plan an bail out ascent for a
CCR dive, add a one minute dive segment in the end with a setpoint value of 0. The decompresseion
algorithm does not switch decogases automatically in CCR mode (but of course for bail out ascents).
[[S_Replan]]
=== Modifying an existing dive plan
Normally, when a dive plan has been saved, it is accessible from the *Dive List*, like any
other dive log. Within the *Dive List* there is not a way to change a saved dive plan.
To perform changes to a dive plan, select it on the *Dive List*. Then, in the main menu,
select _Log -> Re-plan dive_. This will open the selected dive plan within the dive planner,
allowing changes to be made and saved as usual.
In addition there is the option "Save new". This keeps the original
planned dive and adds a (possibly modified) copy to the dive list. If
that copy is saved with the same start time as the original, the two
dives are considered two versions of the same dive and do not
influence other each during decompression calculation (see next section).
=== Planning for repetitive dives
Repetitive dives can easily be planned if the dates and start times of the
repetitive dive set
is specified appropriately in the top left-hand _Start Time_ field. _Subsurface_
calculates the gas loading figures correctly and the effect of the first dive is
evaluated on later dives.
If one has just completed a long/deep dive and is planning
another dive, then highlight, in the *Dive List*, the dive that has just been completed
and then activate the planner. Depending on the start time of the planned dive,
the planner takes into account the gas loading incurred during the completed dive
and allows planning within these limitations.
If only a few standard configurations are used (e.g. in GUE), then a template dive can
be created conforming to one of the configurations. If one now wishes to plan a dive using
this configuration, just highlight the template dive in the *Dive List* and activate the
planner: the planner takes into account the configuration in the highlighted dive.
=== Printing the dive plan
Selecting the _Print_ button in the planner allows printing of the _Dive Plan Details_
for wet notes. Alternatively one can cut and paste the _Dive Plan Details_ for
inclusion in a text file or word processing document.
Dive plans have many characteristics in common with dive logs (dive profile, dive notes, etc).
After a dive plan has been saved, the dive details and gas calculations are saved in
the *Dive Notes* tab. While a dive plan is being designed, it can be printed using
the _Print_ button in the dive planner. This prints the dive details and gas calculations
in the _Dive Plan Details_ panel of the dive planner. However, after the plan has been saved, it is
represented in a way very similar to a dive log and the gas calculations cannot be
accessed in the same way as during the planning process. The only way to print the
dive plan is to use the _File -> Print_ facility on the main menu in the
same way as for dive logs or by copy and paste to a word processor.
[[S_Configure]]
== Configuring a dive computer
_Subsurface_ enables one to configure a dive computer. Currently the Heinrichs-Weikamp (OSTC 2, OSTC 3) and
Suunto Vyper (Stinger, Mosquito, D3, Vyper, Vytec,
Cobra, Gekko and Zoop) family of dive computers are supported. A large number of settings of these dive computers
can be read and changed to different values. As a first step, ensure that the appropriate hardware driver
is installed for the dive computer and that the device name of the dive computer is known.
See <<_appendix_a_operating_system_specific_information_for_importing_dive_information_from_a_dive_computer,APPENDIX A>> for information on how to do this.
Once the dive computer is connected to the _Subsurface_ computer, select _File -> Configure dive
computer_ from the _Main Menu_. Provide the appropriate device name in the text box at the
top of the configuration panel that opens and select the appropriate dive
computer model from the panel on the lefthand (see image below).
image::images/Configure_dc_f20.jpg["FIGURE: Configure dive computer",align="center"]
Using the appropriate buttons on the configuration panel, the following actions can be performed:
- *Retrieve available details*. This loads the existing configuration from the dive computer
to _Subsurface_, showing this in the configuration panel.
- *Save changes to device*. This changes the configuration of the
dive computer to correspond to the information shown in the configuration panel.
- *Backup*. This saves the configuration data to a file. _Subsurface_ asks for
a file location and file name for the saved information.
- *Restore backup*. This loads the information from a backup file and displays it
in the configuration panel.
- *Update firmware*. If new firmware is available for the dive computer, this is
loaded into the dive computer.
== Description of the Subsurface Main Menu items
This section describes the functions and operation of the items in the Main Menu
of Subsurface. Several of the items below are links to sections of this manual
dealing with the appropriate operations.
=== File
- <<S_NewLogbook,_New Logbook_>> - Close the currently open dive logbook and
clear all dive information.
- _Open logbook_ - This opens the file manager in order to select a dive
logbook to open.
- _Save_ - Save the dive logbook that is currently open.
- _Save as_ - Save the current logbook under a different file name.
- _Close_ - Close the dive logbook that is currently open.
- <<S_ExportLog,_Export_>> - Export the currently open dive logbook (or
the selected dives in the logbook) to one of several formats.
- <<S_PrintDivelog,_Print_>> - Print the currently open logbook.
- <<S_Preferences,_Preferences_>> - Set the _Subsurface_ preferences.
- <<S_Configure,_Configure dive computer_>> - Edit the configuration of a dive computer.
- _Quit_ - Quit _Subsurface_.
=== Import
- <<S_ImportDiveComputer,_Import from dive computer_>> - Import dive information
from a dive computer.
- <<Unified_import,_Import Log Files_>> - Import dive information from a file in
in a _Subsurface_-compatible format.
- <<S_Companion,_Import GPS data from Subsurface web service_>> - Load GPS
coordinates from the _Subsurface_ mobile phone app.
- <<S_ImportingDivelogsDe,_Import from Divelogs.de_>> - Import dive information
from _www.Divelogs.de_.
=== Log
- <<S_EnterData,_Add Dive_>> - Manually add a new dive to the *Dive List* panel.
- <<S_DivePlanner,_Plan Dive_>> - This feature allows the planning of dives.
- <<S_Replan,_Re-plan dive_>> - Edit a dive plan that has been saved into the *Dive List*.
- <<S_CopyComponents,_Copy dive components_>> - By selecting this option, one can copy information
from several fields of a dive log onto the clipboard.
- _Paste dive components_ - Paste, into the selected dives in the *Dive List*,
the information copied using the _Copy dive components_ option.
- <<S_Renumber,_Renumber_>> - Renumber the dives listed in the *Dive List*
panel.
- <<S_Group,_Auto Group_>> - Group the dives in the *Dive List* panel into dive
trips.
- <<S_DeviceNames,_Edit Device Names_>> - Edit the names of dive computers to facilitate your logs.
- <<S_Filter,_Filter divelist_>> - Select only some dives, based on specific tags or dive criteria.
=== View
- <<S_ViewPanels,_All_>> - View the four main _Subsurface_ panels
simmultaneously.
- <<S_ViewPanels,_Dive List_>> - View only the *Dive List* panel.
- <<S_ViewPanels,_Profile_>> - View only the *Dive Profile* panel.
- <<S_ViewPanels,_Info_>> - View only the *Dive Notes* panel.
- <<S_ViewPanels,_Globe_>> - View only the *World Map* panel.
- _Yearly Statistics_ - Display summary statistics about dives during this and past
years.
- _Prev DC_ - Switch to previous dive computer.
- _Next DC_ - Switch to next dive computer.
- _Full Screen_ - Toggles Full Screen mode.
=== Help
- _About Subsurface_ - Show a panel with the version number of _Subsurface_ as
well as licensing information.
- _Check for updates_ - Find out whether a newer version of Subsurface is available
on the http://subsurface-divelog.org/[_Subsurface_ web site].
- <<S_UserSurvey,_User survey_>> - Help to make _Subsurface_ even better by taking part in our user survey.
- _User manual_ - Open a window showing this user manual.
== APPENDIX A: Operating system specific information for importing dive information from a dive computer.
=== Make sure that the OS has the required drivers installed
[icon="images/icons/drivers.jpg"]
[NOTE]
The operating system of the desktop computer needs the appropriate drivers in
order to communicate with the dive computer in whichever way the dive
computer prefers (e.g. bluetooth, USB, infra-red).
* On Linux users need to have the correct kernel
module loaded. Most distributions will do this automatically, so the
user does not need to load kernel modules. However, some communication
protocols require an additional driver, especially for rarely used
technology such as infra-red.
* On Windows, the OS should offer to download the correct
driver once the user connects the dive computer to the USB port and
operating system sees the equipment for the first time.
* On a Mac users sometimes have to manually hunt for the correct
driver. For example the correct driver for the Mares Puck
devices or any other dive computer using a USB-to-serial interface
based on the Silicon Labs CP2101 or similar chip can be found as
_Mac_OSX_VCP_Driver.zip_ at the
http://www.silabs.com/support/pages/document-library.aspx?p=Interface&f=USB%20Bridges&pn=CP2101[Silicon Labs document and software repository].
[[S_HowFindDeviceName]]
=== How to Find the Device Name for USB devices and set its write permission
[icon="images/icons/usb.jpg"]
[NOTE]
When a user connects the dive computer by using a USB connector, usually
_Subsurface_ will either propose a drop down list that contains the
correct device name (or mount point for the Uemis Zurich), or it will
disable the device select drop down if no device name is needed at
all. In the rare cases where this doesn't work, here are some
suggestions of ways to find out what the device name is:
.On Windows:
Simply try COM1, COM2, etc. The drop down list should contain all connected COM
devices.
.On MacOS:
The drop down box should find all connected dive computers.
.On Linux:
There is a definitive way to find the port:
- Disconnect the USB cable from the dive computer
- Open a terminal
- Type the command: 'dmesg' and press enter
- Plug in the USB cable of the dive computer
- Type the command: 'dmesg' and press enter
A message similar to this one should appear:
usb 2-1.1: new full speed USB device number 14 using ehci_hcd
usbcore: registered new interface driver usbserial
USB Serial support registered for generic
usbcore: registered new interface driver usbserial_generic
usbserial: USB Serial Driver core
USB Serial support registered for FTDI USB Serial Device
ftdi_sio 2-1.1:1.0: FTDI USB Serial Device converter detected
usb 2-1.1: Detected FT232BM
usb 2-1.1: Number of endpoints 2
usb 2-1.1: Endpoint 1 MaxPacketSize 64
usb 2-1.1: Endpoint 2 MaxPacketSize 64
usb 2-1.1: Setting MaxPacketSize 64
usb 2-1.1: FTDI USB Serial Device converter now attached to ttyUSB3
usbcore: registered new interface driver ftdi_sio
ftdi_sio: v1.6.0:USB FTDI Serial Converters Driver
The third line from the bottom shows that the FTDI USB adapter is
detected and connected to +ttyUSB3+. This information can now be used in
the import settings as +/dev/ttyUSB3+ which directs Subsurface to the correct
USB port.
Ensuring that the user has write permission to the USB serial port:
On Unix-like operating systems the USB ports can only be accessed by users who
are members
of the +dialout+ group. If one is not root, one may not be a member of
that group and
will not be able to use the USB port. Let us assume one's username is 'johnB'.
- As root, type: +usermod -a -G dialout johnB+ (Ubuntu users: +sudo usermod
-a -G dialout johnB+)
This makes johnB a member of the +dialout+ group.
- Type: +id johnB+ This lists all the groups that johnB belongs to and
verifies that
the appropriate group membership has been created. The +dialout+ group should
be listed
among the different IDs.
- Under some circumstances this change takes only effect (eg. on Ubuntu) after
one logs out and then logs in again.
With the appropriate device name (e.g. +dev/ttyUSB3+) and with write permission
to the USB
port, the dive computer interface can connect and one should be able to import
dives.
[[S_HowFindBluetoothDeviceName]]
=== Setting up bluetooth enabled devices
[icon="images/icons/bluetooth.jpg"]
[NOTE]
For dive computers communicating through bluetooth like the Heinrichs
Weikamp Frog or the Shearwater Predator and Petrel there is a
different procedure to get the devices name to communicate with
_Subsurface_. Follow these steps:
* *For the dive computer, after enabling Bluetooth, ensure it is in Upload mode.*
For Bluetooth pairing of the dive computer, refer to the
manufacturer's user guide. When using a Shearwater Predator/Petrel, select
_Dive Log -> Upload Log_ and wait for the _Wait PC_ message.
* *Pair the _Subsurface_ computer with the dive computer.*
.On Windows:
Bluetooth is most likely already enabled. For pairing with the dive computer choose
_Control Panel -> Bluetooth Devices -> Add Wireless Device_.
This should bring up a dialog showing your dive computer (in Bluetooth mode) and
allowing pairing. Right click on it and choose _Propertie s-> COM
Ports_ to identify the port used for your dive computer. If there are several
ports listed, use the one saying "Outgoing" instead of "Incoming".
For downloading to _Subsurface_, the _Subsurface_ drop-down list should contain
this COM port already. If not, enter it manually.
Note: If there are issues afterwards when downloading from the dive computer using
other software, remove the existing pairing with the dive computer.
.On MacOS:
Click on the Bluetooth symbol in the menu bar and select _Set up
Bluetooth Device..._. The dive computer should then show up in the list of devices. Select it and go
through the pairing process. This step should only be needed once for
initial setup.
Once the pairing is completed the correct device is shown in the
'Device or Mount Point' drop-down in the _Subsurface_ *Import* dialog.
.On Linux
Ensure Bluetooth is enabled on the _Subsurface_ computer.
On most common distributions this should be true out of the box and
pairing should be straight forward. For instance, Gnome3 shows a
Bluetooth icon in the upper right corner of the desktop where one selects 'Set
up New Device'. This should show a dialog where one can select the
dive computer (which already should be in Bluetooth mode) and pair it.
If a PIN is required, try manually setting '0000'.
In the rare cases where the above is not true, then
depending on your system, try +initd+ or +systemd+. This might be different
and also involve loading modules specific to your hardware. In case your system
is running +systemd+, manually run +systemctl start bluetooth.service+ to
enable it, in case of +initd+, run something like +rc.config start bluetoothd+ or
+/etc/init.d/bluetooth start+.
One may also use a manual approach by using such commands:
* +hciconfig+ shows the Bluetooth devices available on your
computer (not dive computer), most likely one will see a hci0, if not
try +hcitool -a+ to see inactive devices and run +sudo
hciconfig hci0 up+ to bring them up.
* +hcitool scanning+ gets a list of bluetooth enabled
client devices, look for the dive computer and remember the MAC
address are shown there
* +bluez-simple-agent hci0 10:00:E8:C4:BE:C4+ pairs
the dive computer with the bluetooth stack of the _Subsurface_ computer, copy/paste
the MAC address from the output of 'hcitool scanning'
Unfortunately on Linux binding to a communication device has to be done
manually by running:
* +rfcomm bind /dev/rfcomm0 10:00:E8:C4:BE:C4+ binds the dive
computer to a communication device in the desktop computer, in case rfcomm is
already taken use rfcomm1 or up. IMPORTANT: Copy/paste the MAC address
from the output of +hcitool scanning+, the MAC address shown above will not
work.
For downloading dives in _Subsurface_ specify the device name connected to the MAC
address in the last step above, e.g. _/dev/rfcomm0_.
== APPENDIX B: Dive Computer specific information for importing dive data.
[[S_ImportUemis]]
=== Importing from Uemis Zurich
[icon="images/icons/iumis.jpg"]
[NOTE]
_Subsurface_ downloads the information
stored on the SDA (the built-in file system of the Uemis) including
information about dive spots and
equipment. Buddy information is not yet downloadable.
Things are very similar to a normal USB-connected dive computer
(the Uemis is one of those that recharge when connected to the USB port).
The main difference is that one does not enter a
device name, but instead the location where the UEMISSDA file system is
mounted once connected to the dive computer. On Windows this is a drive letter (
often 'E:' or 'F:'), on a Mac this is
'/Volumes/UEMISSDA' and on Linux systems this differs depending on the
distribution. On Fedora it usually is
'/var/run/media/<your_username>/UEMISSDA'. In all cases _Subsurface_
should suggest the correct location in the drop down list.
After selecting the above device name, download the
dives from the Uemis Zurich. One technical issue with the Uemis Zurich
download implementation (this is a Uemis firmware limitation, not a
_Subsurface_ issue) is that one cannot download more than about 40-50
dives without running out of memory on the SDA. This will usually only
happen the very first time one downloads dives from the Uemis Zurich.
Normally when downloading at the end of a day or even after a dive
trip, the capacity is sufficient. If _Subsurface_ displays an error
that the dive computer ran out of space the solution is straight
forward. Disconnect the SDA, turn it off and on again, and reconnect
it. You can now retry (or start a new download session) and the
download will continue where it stopped previously. One
may have to do this more than once, depending on how many dives are
stored on the dive computer.
[[S_ImportingGalileo]]
=== Importing from Uwatec Galileo
[icon="images/icons/Galileo.jpg"]
[NOTE]
The Uwatec Galileo dive computers use infra red (IrDA) communication
between the dive computer and Subsurface. The Uwatec hardware uses
a USB dongle based on the serial infra-red (SIR) protocol and the
MSC7780 IrDA controller manufactured by MosChip
and marketed by Scubapro and some electronics companies.
Under Linux, the kernel
already provides for communication using the IrDA protocol. However,
the user additionally needs to load a driver for the IrDA interface
with the dive computer. The easiest way is to load the *irda-tools*
package from the http://irda.sourceforge.net/docs/startirda.html[Linux IrDA Project].
After the installation of the irda-tools, the *root user* can specify a device name
from the console as follows:
+irattach irda0+
After executing this command, Subsurface will recognise the Galileo
dive computer and download dive information.
Under Windows, a similar situation exists. Drivers for the MCS7780 are
available from some Internet web sites e.g.
http://www.drivers-download.com/Drv/MosChip/MCS7780/[www.drivers-download.com].
For the Apple Mac, IrDA communication via the MCS7780 link is not
available for OSX 10.6 or higher.
[[S_ImportingDR5]]
=== Importing from Heinrichs Weikamp DR5
[icon="images/icons/HW_DR5.jpg"]
[NOTE]
When mounted as a USB drive the Heinrichs Weikamp DR5 saves a single UDDF file
for every dive.
Mark all the dives you'd like to import or open.
Note: The DR5 does not seem to store gradient factors nor deco information, so
for _Subsurface_ it is not possible to display them. Adjust the gradient
factors in the _Graph Settings_ in _Subsurface_ to generate a deco overlay in the
_Subsurface_ *Dive Profile* panel but please note that the deco calculated by
_Subsurface_ will most likely differ from the one displayed on the DR5.
[[S_ImportingXDeep]]
=== Importing from xDEEP BLACK
[icon="images/icons/HW_xdeepblack.jpg"]
[NOTE]
Each dive has to be individually saved as UDDF file using "Export UDDF" option in BLACK's logbook menu.
When mounted as a USB drive UDDF files are available in LOGBOOK directory.
Note: The xDEEP BLACK saves NDL time but does not seem to store gradient factors nor deco information, so
for _Subsurface_ it is not possible to display them. Adjust the gradient
factors in the _Graph Settings_ in _Subsurface_ to generate a deco overlay in the
_Subsurface_ *Dive Profile* panel but please note that the deco calculated by
_Subsurface_ will most likely differ from the one displayed on the xDEEP BLACK.
=== Importing from Shearwater Predator using Bluetooth
[icon="images/icons/predator.jpg"]
[NOTE]
Using a Shearwater Predator one may be able to pair Bluetooth but then encounter
issues when downloading, showing errors like _Slip RX: unexp. SLIP END_ on the
Predator.
This might also arise when using other dive log software and operating
systems other than Linux. We have no detailed idea about the source and how to fix
this, but it is reported to be solved sometimes by one of these steps:
* use the Bluetooth dongle which came with the Shearwater Predator instead of
the built-in one of the _Subsurface_ computer
* switch to different Bluetooth drivers for the same hardware
* switch off WiFi while using Bluetooth
[[S_PoseidonMkVI]]
=== Importing from Poseidon MkVI Discovery
[icon="images/MkVI.jpeg"]
[NOTE]
Download of dive logs from the MkVI is performed using a custom communications
adapter and the _Poseidon PC Configuration Software_, obtained when purchasing
the MKVI equipment. The latter is a Windows application allowing configuration
of equipment and storage of dive logs. Communication between dive computer and
desktop computer utilises the IrDA infra-red protocol. Only data for one dive
can be downloaded at a time, comprising three files:
- Setup configuration for the dive and key dive parameters (file with a .txt
extension)
- Dive log details (file with a .csv extension)
- Redbook format dive log (file with .cvsr extension). This is a compressed
version of the dive log using a proprietary format.
_Subsurface_ accesses the .txt and the .csv files to obtain dive log information.
=== Importing from APD Inspiration CCR
[icon="images/APDComputer.jpg"]
[NOTE]
The dive logs of an APD Inspiration or similar CCR dive computer are downloaded using
a communications adapter and _AP Communicator_, obtained when
purchasing the equipment. The dive logs can be viewed using the _AP Log Viewer_,
within Windows or Mac/OS. However, APD logs can be viewed and managed from within
_Subsurface_ (together with dives using many other types of dive computer). The
APD inspiration dive logs are imported into _Subsurface_ as follows:
- Open a dive within the _AP Log Viewer_.
- Select the tab at the top of the screen, entitled "_Data_".
- If the raw dive log data show on the screen, click on "_Copy to Clipboard_".
- Open a text editor, e.g. Notepad (Windows), TextWrangler (Mac).
- Copy the contents of the clipboard into the text editor and save the text file
with a filename extension of .CSV
- Within _Subsurface_, select _Import -> Import log files_ to open the xref:Unified_import[universal import dialogue].
- In the dropdown list towards the bottom right of the dialogue, select "_CSV files_".
- On the list of file names select the .CSV file that has been created above. An import
dialogue opens.
- In the dropdown list on the middle right labeled '_Pre-configured imports_",
select _APD Log Viewer_.
- Ensure the other settings for the ADP dive log are appropriate, then select _OK_.
The APD dive log will appear within _Subsurface_.
== APPENDIX C: Exporting Dive log information from external dive log software.
The import of dive log data from external dive log software is mostly performed
using
the dialogue found by selecting _Import_ from the Main Menu, then clicking on
_Import Log Files_. This is a single-step process, more information about which
can be found
xref:Unified_import[here.]
However, in some cases, a two-step process may be required:
1. Export the foreign dive log data to format that is accessible from
_Subsurface_.
2. Import the accessible dive log data into _Subsurface_.
This appendix provides some information about approaches to export dive log
data from foreign
dive log software. The procedures below mostly apply to Linux and/or Windows.
[[S_ImportingDivesSuunto]]
=== Exporting from *Suunto Divemanager (DM3, DM4 or DM5)*
[icon="images/icons/suuntologo.jpg"]
[NOTE]
DiveManager is a MS Windows application for Suunto dive computers.
Divemanager 3 (DM3) is an older version of the Suunto software. More recent
Suunto dive computers use Divemanager version 4 or 5 (DM4 or DM5). The
different versions of Divemanager use different methods and different file naming
conventions to export dive log data.
*Divemanager 3 (DM3):*
1. Start 'Suunto Divemanager 3' and log in with the name containing the logs
2. Do not start the import wizard to import dives from the dive computer.
3. In the navigation tree on the left side of the program-window, select the appropriate
dives.
4. Within the list of dives, select the dives you would like to import later:
* To select certain dives: hold 'ctrl' and click the dive
* To select all dives: Select the first dive, hold down shift and
select the last dive
5. With the dives marked, use the program menu _File -> Export_
6. The export pop-up will show. Within this pop-up, there is one field called 'Export Path'.
* Click the browse button next to the field Export Path
** A file-manager like window pops up
** Navigate to the directory for storing the
Divelog.SDE file
** Optionally change the name of the file for saving
** Click 'Save'
* Back in the Export pop-up, press the button 'Export'
7. The dives are now exported to the file Divelog.SDE.
*Divemanager 4 (DM4) and Divemanager 5 (DM5):*
DM4 and DM5 use identical mechanisms for exporting dive logs.
To export a divelog from Divemanager one needs to locate the DM4/DM5 database
where the dives are stored. the user can either look for the original
database or make a backup of the dives. Both methods are described here.
Locating the Suunto DM4 (or DM5) database:
1. Start Suunto DM4/DM5
2. Select 'Help -> About'
3. Click 'Copy' after text 'Copy log folder path to clipboard'
4. Now open Windows Explorer
5. Paste the address to the path box at the top of the File Explorer
6. The database is called DM4.db or DM5.db
Making a backup copy of the Suunto DM4/DM5 database:
1. Start Suunto DM4/DM5
2. Select 'File - Create backup'
3. From the file menu select the location and name for the backup, we'll
use DM4 (or DM5) in here with the default extension .bak
4. Click 'Save'
5. The dives are now exported to the file DM4.bak (or DM5.bak)
=== Exporting from Atomic Logbook
[[Atomic_Export]]
[NOTE]
Atomic Logbook is a Windows software by Atomic Aquatics. It allows
downloading of dive information from Cobalt and Cobalt 2 dive computers.
The divelog is kept in a SQlite database at
C:\ProgramData\AtomicsAquatics\Cobalt-Logbook\Cobalt.db. This file can
be directly imported to Subsurface.
=== Exporting from Mares Dive Organiser V2.1
[[Mares_Export]]
[icon="images/icons/mareslogo.jpg"]
[NOTE]
Mares Dive Organiser is a Windows application. The dive log is kept as a
Microsoft SQL Compact Edition database with a '.sdf' filename extension. The
database includes all Dive Organiser-registered divers on the particular
computer and all Mares dive computers used. The safest way to obtain a copy
of the dive database is to export the information to another compatible format
which can be imported into _Subsurface_.
1. Within Dive Organiser, select
_Database -> Backup_ from the main menu and back up the database to the desk
top.
This creates a zipped file DiveOrganiserxxxxx.dbf.
2. Rename the file to
DiveOrganiserxxxxx.zip. Inside the zipped directory is a file
_DiveOrganiser.sdf_.
3. Extract the _.sdf_ file from the zipped folder to your Desktop.
4. The password for accessing the .zip file is _mares_.
[[S_ImportingDivingLog]]
=== Exporting from *DivingLog 5.0*
[icon="images/icons/divingloglogo.jpg"]
[NOTE]
Unfortunately DivingLog XML files give us no
indication on the preferences set on one's system. So in order for
_Subsurface_ to be able to successfully import XML files from DivingLog
one first needs to ensure that DivingLog is configured
to use the Metric system (one can easily change this within Diving Log by
selecting 'File -> Preferences -> Units and Language' by clicking the 'Metric'
button). Then do the following:
1. In DivingLog open the 'File -> Export -> XML' menu
2. Select the dives to export
3. Click on the export button and select the filename
[[S_Appendix_D]]
== APPENDIX D: Exporting a spreadsheet to CSV format
Many divers keep a diving log in some form of a digital file, commonly a spreadsheet
with various fields of information. These logs can be easily imported into _Subsurface_
(xref:S_ImportingManualCSV[Importing dives from_manually kept CSV file]), after the
spreadsheet is converted in a .CSV file.
This section explains the procedure to convert a diving logbook stored in a spreadsheet
to a .CSV file that will later be imported from _Subsurface_.
Creating a .CSV is a straightforward task, although the procedure is somewhat different
according to which spreadsheet program is used.
The first step is to organize the diving data in the spreadsheet, so that the first row
contains the names (or titles) of each column and the information for each dive is stored in a single row.
_Subsurface_ supports many data items (Dive #, Date,
Time, Duration, Location, GPS, Max Depth, Mean Depth, Buddy, Notes, Weight and Tags).
The user can organize dive data following a few simple rules:
1. Date: use one of the following formats: yyyy-mm-dd, dd.mm.yyyy, mm/dd/yyyy
2. Duration: the format should be minutes:seconds.
3. Unit system: only one unit system shold be used (i.e., no mixture between imperial and metric units)
4. Tags and buddies: values should be separated using a comma.
5. GPS position: users must use decimal degrees, e.g. 30.22496 30.821798
=== _LibreOffice Calc_ and _OpenOffice Calc_
These are open source spreadsheet applications forming parts of larger open source office suite applications. The user interaction with _LibreOffice_ and _OpenOffice_ is very similar.
In Libreoffice Calc the time format should be set to minutes:seconds - [mm]:ss and dates should be set to one of: yyyy-mm-dd, dd.mm.yyyy, mm/dd/yyyy. A typical dive log may look like this:
image::images/LOffice_spreadsheetdata.jpg["FIGURE: Spreadsheet data",align="center"]
To export the data as a .CSV file from within LibreOffice click _File -> Save As_. On the dialogue that comes up, select the _Text CSV (.csv)_ as the file type and select the option _Edit filter settings_.
image::images/LOffice_save_as_options.jpg["FIGURE: Save as options",align="center"]
After selecting _Save_, select the appropriate field delimiter (choose _Tab_ to prevent conflicts with the comma when using this as a decimal point), then select _OK_.
image::images/LOffice_field_options.jpg["FIGURE: Field options",align="center"]
One can double check the .CSV file by opening it with a text editor, and then import the dive data as explained on the section xref:S_ImportingManualCSV[Importing dives from manually kept CSV files].
=== Microsoft _Excel_
The field delimiter (called "_list separator_" in Microsoft manuals) is not accessible
from within _Excel_ and needs to be set through the _Microsoft Control Panel_. After changing the
separator character, all software on the Windows machine use the new character as a separator.
One can change the character back to the default character by following the same procedure, outlined below.
- In Microsoft Windows, click the *Start* button, and then select _Control Panel_ from the list on the right-hand side.
- Open the _Regional and Language Options_ dialog box.
- Do one of the following:
** In Windows 7, click the _Formats_ tab, and then click _Customize this format_.
** In Windows XP, click the _Regional Options_ tab, and then click _Customize_.
- Type a new separator in the _List separator_ box. To use a TAB-delimited file, type the word TAB in the box.
- Click _OK_ twice.
Below is an image of the _Control Panel_:
image::images/Win_SaveCSV2.jpg["FIGURE: Win List separator",align="center"]
To export the dive log in CSV format:
With the dive log opened in _Excel_, select the round Windows button at the top left, then _Save As_.
image::images/Win_SaveCSV1.jpg["FIGURE: Excel save as option",align="center"]
Click on the left-hand part of the _Save as_ option, NOT on the arrow on the right-hand. This brings up a dialogue for saving the spreadsheet in an alternative format. From the dropdown list at the bottom of the dialogue, marked _Save as Type:_, select _CSV(Comma delimited) (*.CSV)_. Ensure that the appropriate folder has been selected to save the CSV file into.
image::images/Win_SaveCSV3.jpg["FIGURE: Excel save CSV dialogue",align="center"]
Select the _Save_ button. The CSV-formatted file is saved into the folder that was selected. One can double check the .CSV file by opening it with a text editor, and then import the dive data as explained on the section xref:S_ImportingManualCSV[Importing dives from manually kept CSV files].
== APPENDIX E: FAQs.
=== Subsurface appears to miscalculate gas consumption and SAC
[[SAC_CALCULATION]]
'Question': I dived with a 12.2 l tank, starting with 220 bar and ending with 100 bar, and I calculate a different SAC compared what _Subsurface_ calculates. Is _Subsurface_
miscalculating?
'Answer': Not really. What happens is that _Subsurface_ actually calculates gas
consumption differently - and better - than you expect.
In particular, it takes the incompressibility of the gas into account.
Traditionally, Gas consumption and SAC should be:
+consumption = tank size x (start pressure - end pressure)+
and that's true for an ideal gas, and it's what you get taught in dive theory.
But an "ideal gas" doesn't actually exist, and real gases actually don't compress
linearly with pressure. Also, you are missing the fact that one atmosphere of
pressure isn't actually one bar.
So the *real* calculation is:
+consumption = (amount_of_air_at_beginning - amount_of_air_at_end)+
where the amount of air is *not* just "tank size times pressure in bar".
It's a combination of: "take compressibility into account" (which is a fairly
small issue under 220 bar - you'll see more differences when you do high-pressure
tanks with 300bar) and "convert bar to atm" (which is the majority of your discrepancy).
Remember: one ATM is ~1.013 bar, so without the compressibility, your gas use is:
+12.2*((220-100)/1.013)+
which is about 1445, not 1464. So there was 19 l too much in your simple
calculation that ignored the difference between 1 bar and one ATM.
The compressibility does show up above 200 bar, and takes that 1445 down
about eight litres more, so you really did use only about 1437 l of air at surface pressure.
So be happy: your SAC really is better than your calculations indicated.
Or be sad: your cylinder contains less air than you thought it did.
And as mentioned, the "contains less air than you thought it did" really
starts becoming much more noticeable at high pressure. A 400 bar really does not
contain twice as much air as a 200 bar one. At lower pressures, air acts pretty much like an ideal gas.
=== Some dive profiles have time discrepancies with the recorded samples from my dive computer...
_Subsurface_ ends up ignoring surface time for many things (average depth, divetime, SAC, etc).
'Question': Why do dive durations in my dive computer differ from that given by _Subsurface_?
'Answer': For example, if you end up doing a weight check (deep enough to trigger the "dive started")
but then come back up and wait five minutes for your buddies, your dive computer may say
that your dive is 50 minutes long - because you have fifty minutes worth of samples - but
subsurface will say it's 45 minutes - because you were actually diving for 45 minutes.
It's even more noticeable if you do things like divemastering the initial OW dives, when
you may stay in the water for a long time, but spend most of it at the surface. And then
you don't want that to count as some kind of long dive”.
|